background image

2

H

OW

 

TO

 

OPERATE

 

THE

 

ADDRESS

 

CARDS

?

For more information, consult the following documents:

The chiller operation manual: installing BMS address card +
defining the BMS settings.

Installation manual of gateway.

Operation manual of gateway.

T

HE

 

VARIABLES

 

DATABASE

The BMS or supervisory system and the address card
communicate through a fixed set of variables, also called address
numbers. Hereafter, you will find the information you need about
the digital, integer and analogue variables that the BMS or
supervisory system can read from or write to the chiller’s address
card.

Digital variables

A

X
X
X
X
X
X
X
X
X
X

X

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

X

X
X
X

B

X
X
X
X
X
X
X

X

X
X
X
X

X
X
X
X
X
X

X
X
X
X
X

X

Air cooled 80~120HP

Air cooled 160~200HP

Water cooled 120~200HP

PCB B:
-

PCB B:
-

PCB B:
-

PCB B:
-

-

-
-
-
-

Note

 

These chillers have two PCBs: PCB A & B.

PCB A: general parameters and circuit 1 parameters
PCB B: circuit 2 parameters

If a parameter is marked with X in column of  PBC A or B, then the
parameter is present on the marked PCB.

Address

Read/

Write

Description

Comments

Unit status
Enable remote on-off
Unit safety active
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5
Digital input 6
Digital input 7

Digital input 8

Digital input 9
Digital input 10
Digital input 11
Digital output 1
Digital output 2
Digital output 3
Digital output 4
Digital output 5
Digital output 6
Digital output 7
Digital output 8
Digital output 9
Digital output 10
Digital output 11
Digital output 12
Digital output 13
Circuit safety active
Guard timer active
Start up timer active
Anti-recycling timer active
Load up timer active
Load down timer active
On-off command

High-pressure setback active
Digital input 12

25% is installed
V-a meter installed
DICN OPTION: Network
safety active

r
r
r
r
r
r
r
r
r
r

r

r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r

w

r
r

r
r
r

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

36
37

38
39
40

1=on 0=off
1=yes 0=no
1=yes 0=no
Low pressure switch
High pressure switch
Reverse phase protector
Overcurrent
Discharge thermal protector
Compressor thermal protector
PCB A:
Flow-switch

PCB B:
Enable/
Disable C1

PCB A:
Flow-switch

PCB A:
Flow-switch

PCB A:
Bypass

PCB B:
Enable/
disable C2

PCB A:
Bypass

PCB A:
Bypass:

Dual setpoint
Digital input remote on-off
Emergency
Star
Delta
Compressor status
Pump
General situation of alarm
12%
25%
40%
Fan 1
Fan 2
Fan 3
Evaporator heater

Fan 1
Fan 2
Fan 3
Evaporator heater

70%
1=yes 0=no
1=not zero 0=zero
1=not zero 0=zero
1=not zero 0=zero
1=not zero 0=zero
1=not zero 0=zero
If 1 is written, then toggle status of the unit.
After this action the controller resets this parameter.
0=not active 1=Active

Enable/disable capacity
limitation

Enable/disable capacity
limitation

0=no 1=yes
0=no 1=yes
0=no 1=yes

Reviews: