4
Air cooled 80~120HP
Air cooled 160~200HP Water cooled 120~200HP
Integer variables
Address
Read/
Write
Description
Comments
27
28
29
30
31
32
33
34
35
36
37
38
39
r
r
r
r
r
r
r
r
r
r/w
r/w
r
r/w
X
X
X
X
X
X
X
X
X
X
X
X
X
Water/air cooled unit
Cooling only/heat pump
Unique eprom parameter
Eprom version (higher part)
Eprom version (lower part)
DICN OPTION: status of Master
DICN OPTION: status of Slave 1
DICN OPTION: status of Slave 2
DICN OPTION: status of Slave 3
DICN OPTION: Mode
DICN OPTION: number of Slaves
DICN OPTION: Master or Slave
DICN OPTION: cooling/heating
mode
0=air-cooled unit
1=water-cooled unit
0=cooling only
1=heat pump
Example 12 (V1.
012
)
0=normal 1=standby 2=disconnected 3=C1 safety 4=C2 safety
5=unitsafety 6=not present (=empty line on screen)
0=normal 1=standby 2=disconnect
Network setting (only for unit defined as Master)
0=Master 1=Slave 1 2=Slave 2 3=Slave 3
2=AC 80~120HP
7=AC 80~120HP with DICN
OPTION
1=V1 (
V1
.012)
-
-
0=cooling 1=heating
2=double thermostat
5=AC 160~280HP
10=AC 160~280HP
with DICN OPTION
4=WC 120~280HP
9=WC 120~280HP
with DICN OPTION
A
B
A
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B
X
X
X
X
X
X
X
PCB B
-
-
-
-
-
PCB B
-
Analog variables
Address
Read/
Write
Description
Comments
Analog input 2
Analog input 3
Analog input 1
Analog input 7
Analog input 8
Converted analog input 7
Converted analog input 8
Analog input 6
Analog input 5
Actual setpoint
Minimum outlet water
Inlet setpoint 1 cooling
Inlet setpoint 2 cooling
Outlet setpoint 1 cooling
Outlet setpoint 2 cooling
Step length in inlet control
Step difference in inlet control
Step length in outlet control
Step difference in outlet control
Inlet setpoint 1 heating
Inlet setpoint 2 heating
Analog input 4
Inlet evaporator temperature
PCB A
Outlet
evaporator
temp
Outlet evaporator
temp of circuit
Outlet evaporator temp
of circuit
PCB A
Ambient
temp
PCB A
Ambient
temp
PCB B
Mixed outlet
evaporator
temp
PCB A
Inlet
condenser
temp
PCB B
Mixed outlet
evaporator
temp
High pressure
Low pressure
High pressure converted in temperature
Low pressure converted in temperature
Voltage (only if V-A option is installed, if not, value 99.0 displays)
Current (only if V-A option is installed, if not, value 99.0 displays)
User setting (In/outlet setpoint 1 or 2)
Factory setting
User setting
User setting
User setting
User setting
User setting
User setting
User setting
User setting
User setting
User setting
r
r
r
r
r
r
r
r
r
r
r
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r/w
r
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Air cooled 80~120HP
Air cooled 160~200HP Water cooled 120~200HP
DICN OPTION: common evaporator outlet temperature