3.7

Installer settings: Tables to be filled in by
installer

3.7.1

Quick wizard

Setting

Default

Fill in…

Backup heater configuration (only for unified backup heater)
[A.2.1.5]

  BUH type

1 (1P,(1/2))

 

Preferential kWh rate power supply [A.2.1.6]

  Preferential kWh rate

0 (LWT
control)

 

Space heating/cooling settings [A.2.1]

  Unit control method

0 (In room)

 

User interface location

1 (1 LWT
zone)

 

Number of LWT zones

1 (1 LWT
zone)

 

Pump operation mode

1 (Sample)

 

Domestic hot water settings [A.2.2]

  DHW operation

Depends on
model

 

DHW tank heater

Depends on
model

 

DHW pump

0 (No)

 

Thermostats [A.2.2]

  Contact type main

2 (Thermo
ON/OFF)

 

Contact type add.

2 (Thermo
ON/OFF)

 

External sensor

0 (No)

 

Digital I/O PCB [A.2.2.6]

  Ext. backup heat src

0 (No)

 

Solar kit

0 (No)

 

Alarm output

0 (Normally
open)

 

Bottom plate heater

0 (No)

 

Demand PCB [A.2.2.7]

  Demand PCB

0 (No)

 

Energy metering [A.2.2]

  External kWh meter 1

0 (No)

 

External kWh meter 2

0 (No)

 

Capacities (energy metering) [A.2.3]

  Booster heater

0 kW

 

BUH: step 1

Depends on
model

 

BUH: step 2

Depends on
model

 

Bottom plate heater

0 W

 

3.7.2

Space heating/cooling control

Setting

Default

Fill in…

Leaving water temperature: Main zone [A.3.1.1]

  LWT setpoint mode

0 (Absolute)

 

Set weather-dependent heating

25/40/15/−10

 

Set weather-dependent cooling

18/22/35/20

 

Leaving water temperature: Additional zone [A.3.1.2]

  LWT setpoint mode

0 (Absolute)

 

Set weather-dependent heating

25/40/15/−10

 

Set weather-dependent cooling

18/22/35/20

 

Leaving water temperature: Delta T emitter [A.3.1.3]

  Heating

5°C

 

Setting

Default

Fill in…

Cooling

5°C

 

Leaving water temperature: Modulation [A.3.1.1.5]

  Modulated LWT

0 (No)

 

Leaving water temperature: Emitter type [A.3.1.1.7]

  Emitter type

1 (Slow)

 

3.7.3

Domestic hot water control [A.4]

Setting

Default

Fill in…

Setpoint mode

2 (Scheduled
only)

 

Setpoint readout type

0
(Temperature)

 

Maximum setpoint

Depends on
model

 

INFORMATION 

It is recommended NOT to use the selection of ([6

0D]=0,

[A.4.1] Domestic hot water Setpoint mode=Reheat only) in
case of a domestic hot water tank without internal booster
heater.

The  risk  of  space  heating  (cooling)  capacity  shortage/
comfort  problems  is  significant  (in  case  of  frequent
domestic  hot  water  operation,  frequent  and  long  space
heating/cooling interruption will happen).

3.7.4

Contact/helpdesk number [6.3.2]

Setting

Default

Fill in…

Contact/helpdesk number

 

4

Energy saving tips

Tips about room temperature

▪ Make  sure  the  desired  room  temperature  is  never  too  high  (in

heating mode) or too low (in cooling mode), but always according
to  your  actual  needs.  Each  saved  degree  can  save  up  to  6%  of
heating/cooling costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use a weekly schedule for your normal space heating or cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature.  Example:  When  you  have  a  party,  or  when  you
are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode.  Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

Tips about DHW tank temperature

▪ Make sure the number (available hot water for x persons) on the

DHW tank temperature home page is NOT higher than your actual
needs.

 

Summary of Contents for EHVH04S18CA

Page 1: ...re Split English Operation manual Daikin Altherma Low Temperature Split EHBH04CA EHBH08CA EHBH16CA EHBX04CA EHBX08CA EHBX16CA EHVH04S18CA EHVH08S18CA EHVH08S26CA EHVH16S18CA EHVH16S26CA EHVX04S18CA EH...

Page 2: ...ation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Saf...

Page 3: ...he next step when you are programming a schedule in the menu structure Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between disp...

Page 4: ...read out the desired temperature 22 0 C D e s i r e d te m p e r a tu r e To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temp...

Page 5: ...User profile Detailed 1 5 2 0 4 D e s i r e d te m p e r a tu r e Mon Tank 4 1 5 2 0 0 0 0 0 Storage comfort Tue Mon Tank To read out and adjust the desired reheat temperature in reheat mode 1 Go to...

Page 6: ...ay from which you want to copy and press Example Monday 2 Select Copy day and press 3 Set the days you want to copy to Yes and press Example Tuesday Yes Wednesday Yes Thursday Yes and Friday Yes 3 5 4...

Page 7: ...Operation modes Running hours Version Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Operati...

Page 8: ...1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow 3 7 3 Domestic hot water control A 4 Setting Default Fill in Setpoint mode 2 Scheduled only Setpoint read...

Page 9: ...otential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please contact your installer for more information 5 2 To find the contact help...

Page 10: ......

Page 11: ......

Page 12: ...4P313773 1 B 0000000 4P313773 1B 2012 11 Copyright 2012 Daikin...

Reviews: