1 About this document ........................................ 2

2 About the system .............................................. 2

2.1

Components in a typical system layout ....................................

2

3 Operation ........................................................... 3

3.1

Overview: Operation .................................................................

3

3.2

The user interface at a glance ..................................................

3

3.2.1

Buttons .......................................................................

3

3.2.2

Status icons ...............................................................

3

3.3

Space heating/cooling control ...................................................

4

3.3.1

Setting the space operation mode .............................

4

3.3.2

Using the room temperature home page ...................

4

3.3.3

Using the leaving water temperature home pages
(main + additional) .....................................................

4

3.4

Domestic hot water control .......................................................

4

3.4.1

Reheat mode .............................................................

4

3.4.2

Scheduled mode ........................................................

5

3.4.3

Sch reheat mode .........................................

5

3.4.4

Using the DHW tank temperature home page ...........

5

3.4.5

Using the DHW tank booster mode ...........................

5

3.5

Schedules: Example .................................................................

5

3.6

Menu structure: Overview .........................................................

7

3.7

Installer settings: Tables to be filled in by installer ....................

8

3.7.1

Quick wizard ..............................................................

8

3.7.2

Space heating/cooling control ....................................

8

3.7.3

Domestic hot water control [A.4] ................................

8

3.7.4

Contact/helpdesk number [6.3.2] ...............................

8

4 Energy saving tips ............................................ 8

5 Maintenance and service ................................. 9

5.1

Overview: Maintenance and service .........................................

9

5.2

To find the contact/helpdesk number ........................................

9

6 Troubleshooting ................................................ 9

6.1

Symptom: You are feeling too cold (hot) in your living room ....

9

6.2

Symptom: The water at the tap is too cold ...............................

9

7 Glossary ............................................................. 9

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

Document

Contains…

Format

General
safety
precautions

Safety instructions that
you must read before
operating your system

Paper (in the box of the
indoor unit)

Operation
manual

Quick guide for basic
usage

Document

Contains…

Format

User
reference
guide

Detailed step-by-step
instructions and
background information
for basic and advanced
usage

CD/DVD (in the box of the
indoor unit)

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

Available screens

Depending on your system layout and installer configuration, not all
screens in this document may be available on your user interface.

Breadcrumbs

1 8 . 0 ° C >

2 0 . 0 ° C >

2 2 . 0 ° C >
2 4 . 0 ° C >

OK

1

7.4.1.1

E c o  

(

h e a t i n g

)

C o m f o r t  

(

h e a t i n

g )

C o m f o r t  

(

c o o l i n g

)

E c o  

(

c o o l i n g

)

S e l e c t

S c r o l l

R o o m   t e m p e r a t u r e

Breadcrumbs help you to locate
where you are in the menu
structure of the user interface.
This document also mentions
these breadcrumbs.

Example: Go to [7.4.1.1] = Go to

 > User settings > Preset

values  >  Room  temperature  >
Comfort (heating)

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool  down  a  space  (if  a  heating/cooling  heat  pump  model  is

installed)

▪ Produce domestic hot water (if a DHW tank is installed)

2.1

Components in a typical system layout

d

a

b

c

e

f

g

B

C

A

 

A

Main zone. Example: Living room.

B

Additional zone. Example: Bedroom.

C

Technical room. Example: Garage.

a

Outdoor unit heat pump

b

Indoor unit heat pump

c

Domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface in the living room, used as room thermostat

f

Under floor heating

g

Heat pump convectors or fan coil units

INFORMATION 

Indoor  and  domestic  hot  water  tank  can  be  separated  or
integrated depending on the indoor unit type.

 

Summary of Contents for EHVH04S18CA

Page 1: ...re Split English Operation manual Daikin Altherma Low Temperature Split EHBH04CA EHBH08CA EHBH16CA EHBX04CA EHBX08CA EHBX16CA EHVH04S18CA EHVH08S18CA EHVH08S26CA EHVH16S18CA EHVH16S26CA EHVX04S18CA EH...

Page 2: ...ation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Saf...

Page 3: ...he next step when you are programming a schedule in the menu structure Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between disp...

Page 4: ...read out the desired temperature 22 0 C D e s i r e d te m p e r a tu r e To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temp...

Page 5: ...User profile Detailed 1 5 2 0 4 D e s i r e d te m p e r a tu r e Mon Tank 4 1 5 2 0 0 0 0 0 Storage comfort Tue Mon Tank To read out and adjust the desired reheat temperature in reheat mode 1 Go to...

Page 6: ...ay from which you want to copy and press Example Monday 2 Select Copy day and press 3 Set the days you want to copy to Yes and press Example Tuesday Yes Wednesday Yes Thursday Yes and Friday Yes 3 5 4...

Page 7: ...Operation modes Running hours Version Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Operati...

Page 8: ...1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow 3 7 3 Domestic hot water control A 4 Setting Default Fill in Setpoint mode 2 Scheduled only Setpoint read...

Page 9: ...otential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please contact your installer for more information 5 2 To find the contact help...

Page 10: ......

Page 11: ......

Page 12: ...4P313773 1 B 0000000 4P313773 1B 2012 11 Copyright 2012 Daikin...

Reviews: