You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating/cooling
control

How to control space heating/cooling:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules.

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches  between  home  pages  (when  you  are  on  a  home

page).

▪ Goes  to  the  default  home  page  (when  you  are  in  the  menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages. You
can press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens the menu structure (when you are on a home page).
▪ Goes  a  level  up  in  the  menu  structure  (when  you  are

navigating in the menu structure).

▪ Goes  back  1  step  (example:  when  you  are  programming  a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates in the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Goes to the next step when you are programming a schedule

in the menu structure.

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches  between  displaying  actual  and  desired  values,  or

between displaying actual and offset values (if applicable) on
the home pages.

▪ Enables you to activate or deactivate child lock if pressed for

more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed  for  more  than  5  seconds  in  the  main  menu  of  the
menu structure.

INFORMATION 

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
The system will produce domestic hot water for the
indicated number of persons.
The DHW tank booster mode is active or ready to be
activated.
Quiet mode is active.

Holiday mode is active or ready to be actived.

Child lock mode and/or function lock mode is active.

An external heat source is active. Example: Gas
burner.
The disinfection mode is active.

A malfunction occured. You can press 

 to display

more information about the malfunction.
Weather-dependent mode is active.

 

Summary of Contents for EHVH04S18CA

Page 1: ...re Split English Operation manual Daikin Altherma Low Temperature Split EHBH04CA EHBH08CA EHBH16CA EHBX04CA EHBX08CA EHBX16CA EHVH04S18CA EHVH08S18CA EHVH08S26CA EHVH16S18CA EHVH16S26CA EHVX04S18CA EH...

Page 2: ...ation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Saf...

Page 3: ...he next step when you are programming a schedule in the menu structure Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between disp...

Page 4: ...read out the desired temperature 22 0 C D e s i r e d te m p e r a tu r e To temporarily overrule the room temperature schedule 1 Go to the room temperature home page Room 2 Use or to adjust the temp...

Page 5: ...User profile Detailed 1 5 2 0 4 D e s i r e d te m p e r a tu r e Mon Tank 4 1 5 2 0 0 0 0 0 Storage comfort Tue Mon Tank To read out and adjust the desired reheat temperature in reheat mode 1 Go to...

Page 6: ...ay from which you want to copy and press Example Monday 2 Select Copy day and press 3 Set the days you want to copy to Yes and press Example Tuesday Yes Wednesday Yes Thursday Yes and Friday Yes 3 5 4...

Page 7: ...Operation modes Running hours Version Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Operati...

Page 8: ...1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow 3 7 3 Domestic hot water control A 4 Setting Default Fill in Setpoint mode 2 Scheduled only Setpoint read...

Page 9: ...otential value 1975 Periodical inspections for refrigerant leaks may be required depending on the applicable legislation Please contact your installer for more information 5 2 To find the contact help...

Page 10: ......

Page 11: ......

Page 12: ...4P313773 1 B 0000000 4P313773 1B 2012 11 Copyright 2012 Daikin...

Reviews: