7 Technical data

 

Installation manual

19

EHBH/X04~16CA
Daikin Altherma - Low Temperature Split
4P313771-1C – 2012.11

7

Technical data

7.1

Wiring diagram

7.1.1

Wiring diagram – components: Indoor unit

 See  the  internal  wiring  diagram  supplied  with  the  unit  (on  the  inside  of  the  indoor  unit  switch  box  cover).  The  abbreviations  used  are  listed
below.

 

X6Y

A4P

A8P

X1M

X4M

F2B

F1B

X2M

X5M

Q1L

TR1

K3M

K5M

K2M

K1M

A1P

A7P

X7M

X6M

X4M

X6M, X7M

1

15

X5M

X2M

X1M

4D077028 page 1

T1R (A7P)

M1P

B1L

*

R1H (A3P)

FU1

F1T

E4H

E3H

E2H

*

E1H

R1T (A2P)

R4T

R3T

R2T

R1T

*

PHC1

#

M2P

*

F2B

F1B

K5M

TR1

Q1L

K1M, K2M

*

#

#

#

#

*

(*)

*

*

*

X*Y

X*M

SS1 (A4P)

S6S-S9S

S3S

S2S

S1S

R6T

R5T

R2T

R1T (A3P)

Q2L

A7P

#

#

Q1DI, Q2DI

K*R

M3S

(*)

M2S

K3M

*

F1U, F2U

*

DS1 (A8P)

*

*

BSK

*

A8P

A4P

*

*

A4P

*

*

*

A3P

A3P

A3P

A2P

A1P

Domestic hot water tank 
with solar connection

rectifier bridge (only for *16*)

main supply pump

flow sensor

humidity sensor

fuse T 6.3 A 250 V for PCB

thermal fuse backup heater

booster heater (3 kW)

backup heater element (3 kW)

backup heater element (2 kW)

backup heater element (1 kW)

ambient sensor user interface

inlet water thermistor

refrigerant liquid side thermistor

outlet backup heater thermistor

outlet water heat exchanger thermistor

optocoupler input circuit

domestic hot water pump

overcurrent fuse booster heater

overcurrent fuse backup heater

safety contactor BUH (only *9W)

power supply transformer

thermal protector backup heater

contactor backup heater

# : field supply

connector

terminal strip

selector switch

digital power limitation inputs

electrical meter pulse input 2

electrical meter pulse input 1

preferential kWh rate PS contact

external indoor or outdoor 
ambient thermistor

domestic hot water thermistor

external sensor (floor or ambient)

ambient sensor On/OFF thermostat

thermal protector booster heater

6T1 (3~, 230 V, 6 kW)

9WN (3N~, 400 V, 9 kW)

6WN (3N~, 400 V, 6 kW)

6V3 (1N~, 230 V, 6 kW)

3V3 (1N~, 230 V, 3 kW)

Backup heater 
configuration 
(only for *9W)

Ext. thermistor

Heat pump convector

On/OFF thermostat (wireless)

Add LWT:

On/OFF thermostat (wired)

Heat pump convector

Solar pump and control station

Demand PCB

Digital I/O PCB

Ext. outdoor thermistor

Ext. indoor thermistor

Remote user interface

Ext. thermistor

On/OFF thermostat (wireless)

Main LWT:

On/OFF thermostat (wired)

Domestic hot water tank

(*) : standard for *HV*, optional for *HB*

pump driver PCB (only for *16*)

POSITION IN SWITCH BOX

: Booster heater terminal

: Backup heater terminal

earth leakage circuit breaker

relay on PCB

3 way valve for floorheating/ 
domestic hot water

2 way valve for cooling mode

contactor booster heater

fuse 5 A 250 V for digital I/O PCB

dipswitch

solar pump station relay

demand PCB

receiver PCB (wireless 
On/OFF thermostat)

digital I/O PCB

heat pump convector

On/OFF thermostat (PC=power circuit)

solar pumpstation PCB

user interface PCB

Bottom plate heater

* : optional

NOTES to go through before starting the unit

Translation can be found in the installation manual.

LEGEND

User installed options:

: Wiring depending on model

: Several wiring possibilities

: Connection ** continues on page 12 column 2

: PCB

: Not mounted in switch box

: Option

: Field supply

: Wire number 15

: Earth wiring

: Field wiring terminal for DC

: Field wiring terminal for AC

: Main terminal

Part n°

Description

main PCB

**/12.2

 

Summary of Contents for EHBH04CA

Page 1: ...Installation manual Daikin Altherma Low Temperature Split English Installation manual Daikin Altherma Low Temperature Split EHBH04CA EHBH08CA EHBH16CA EHBX04CA EHBX08CA EHBX16CA ...

Page 2: ...ledujícímnormámnebonormativnímdokumentům uskladusaslijedećimstandardom ima ilidrugimnormativnimdokumentom ima uzuvjetdaseonikoristeuskladusnašim uputama megfelelnekazalábbiszabvány ok nakvagyegyébirányadódokumentum ok nak haazokatelőírásszerinthasználják 17 18 19 20 21 22 23 24 25 spełniająwymoginastępującychnormiinnychdokumentównormalizacyjnych podwarunkiemżeużywanesązgodnieznaszymi instrukcjami ...

Page 3: ...4 2 2 Quick wizard Standard 13 4 2 3 Quick wizard Options 13 4 2 4 Quick wizard Capacities energy metering 14 4 2 5 Space heating cooling control 14 4 2 6 Domestic hot water control 15 4 2 7 Contact helpdesk number 15 4 3 Menu structure Overview installer settings 16 5 Commissioning 17 5 1 Checklist before test run 17 5 2 To perform an air purge 17 5 3 To perform a test run 17 5 4 To perform an ac...

Page 4: ...s k Sound plate only for EHBH X16 l Screws for fixing sound plate only for EHBH X16 4 Remove the accessories k l only for EHBH X16 These accessories are located at the bottom of the packaging 3 Installation 3 1 Opening the units 3 1 1 To open the indoor unit 1 Loosen and remove the 2 screws that fix the front panel 2x 2 Tilt the front panel towards you and remove the front panel 3 1 2 To open the ...

Page 5: ...s as shown below 2x 2 1 3 4 4 Lift the unit 1 2 5 Tilt the top of the unit against the wall at the position of the 2 inserted screws 6 Hook the unit against the wall 2 1 2x 3 2x 7 Assemble the unit 1 2 1 2 2 2 3 4x 8 Following step is only applicable for EHBH X16 3 2 2 To install the drain pan kit If a drain pan kit EKHBDPCA2 is required install it before connecting the refrigerant and water pipes...

Page 6: ...f connection with the optional domestic hot water tank see the installation manual of the domestic hot water tank 5 Only applicable for EHBH X16 install the sound plate as shown in the figure below 1 2 4x 3 3 4 2 To fill the water circuit 1 Connect the water supply hose to the drain and fill valve 2 Open the drain and fill valve 3 Make sure that the automatic air purge valve is open at least 2 tur...

Page 7: ...1 To open the indoor unit on page 4 2 Wiring should enter the unit from the bottom 3 Routing of the wiring inside the unit should be as follows For EHBH X04 08 a b c a b c For EHBH X16 a c b a c c c b INFORMATION When installing field supply or option cables foresee sufficient cable length This will make it possible to remove reposition the switch box and gain acces to other components during serv...

Page 8: ...r supply when active 3 5 4 To connect the backup heater power supply CAUTION If the indoor unit has a tank with a built in electrical booster heater EKHW use a dedicated power circuit for the backup heater and booster heater NEVER use a power circuit shared by another appliance This power circuit must be protected with the required safety devices according to the applicable legislation The backup ...

Page 9: ... below should be measured ALWAYS measure the resistance on the contactor clamps K1M K2M and K5M 3 kW 1 230 V 6 kW 1 230 V 6 kW 3 230 V 6 kW 3N 400 V 9 kW 3N 400 V K1M 1 K5M 13 52 9Ω 52 9Ω 52 9Ω K1M 3 105 8Ω 105 8Ω K1M 5 105 8Ω 105 8Ω K1M 3 K1M 5 26 5Ω 26 5Ω 26 5Ω 105 8Ω 105 8Ω K2M 1 K5M 13 26 5Ω 26 5Ω K2M 3 52 9Ω 52 9Ω K2M 5 52 9Ω 52 9Ω K2M 3 K2M 5 52 9Ω 52 9Ω 52 9Ω 52 9Ω 52 9Ω 3 kW 1 230 V 6 kW 1...

Page 10: ... carefully separate the faceplate from the wallplate NOTICE The PCB is mounted in the faceplate of the user interface Be careful NOT to damage it 9 Fix the wallplate of the user interface to wall 10 Connect the wires to the user interface as shown below From the rear b a PCB 1x From the left a PCB b 1x From the top a b PCB b 1x From the top center a PCB b b 1x a Notch this part for the wiring to p...

Page 11: ...To connect the alarm output 1 Connect the alarm output cable to the appropriate terminals as shown in the illustration below X1M X2M 29 X1M YC Y1 Y2 Y3 Y4 A4P X2M a a Installation of EKRP1HB is required 2 Fix the cable with cable ties to the cable tie mountings 3 5 10 To connect the space cooling heating ON OFF output 1 Connect the space cooling heating ON OFF output cable to the appropriate termi...

Page 12: ...overview settings When the installer settings are changed the system will request to confirm When confirmation is complete the screen will shortly turn OFF and busy will be displayed for several seconds The most commonly used installation settings are accessible through the menu structure Their location is mentioned by the breadcrumb indication Additionally all installer settings can also be found...

Page 13: ...ndition 4 2 3 Quick wizard Options Domestic hot water settings Code Description A 2 2 1 E 05 Domestic hot water tank 0 No NOT installed 1 Yes Installed Code Description A 2 2 3 E 07 Tank booster heater 0 Horizontal BSH Installed at side of the tank 1 Backup heater NOT installed 2 N A 3 N A A 2 2 A D 02 Domestic hot water pump 0 No NOT installed 1 Secondary rtrn Installed for instant hot water 2 Di...

Page 14: ...2 Installed 1 pulse kWh 3 Installed 10 pulse kWh 4 Installed 100 pulse kWh 5 Installed 1000 pulse kWh A 2 2 9 D 09 Optional external kWh meter 2 0 No NOT installed 1 Installed 0 1 pulse kWh 2 Installed 1 pulse kWh 3 Installed 10 pulse kWh 4 Installed 100 pulse kWh 5 Installed 1000 pulse kWh 4 2 4 Quick wizard Capacities energy metering Code Description A 2 3 1 6 02 Booster heater capacity kW A 2 3...

Page 15: ...e system 0 Quick Example Small water volume and fan coils 1 Slow Example Large water volume floor heating loops Depending on the system water volume and the heat emitters type the heat up or cool down of a space can take longer This setting can compensate for a slow or a quick heating cooling system by adjusting the unit capacity during the heat up cool down cycle 4 2 6 Domestic hot water control ...

Page 16: ...ooling On temp A 3 3 Setpoint mode Scheduled DHW Domestic hot water DHW A 4 Schedule temperatures Storage comfort SP mode Weather dependent curve Scheduled DHW A 4 2 Setpoint readout type Conversion persons Setpoint readout A 4 3 External sensor Demand PCB Disinfection Operation day Start time Temperature target A 4 4 Duration Backup heater Heat sources A 5 Operation mode Auto emergency operation ...

Page 17: ... pressure relief valve purges water when opened 5 2 To perform an air purge 1 Go to A 7 3 Installer settings Commissioning Air purge 2 Set the type speed and circuit 3 Select Start air purge and press 4 Select OK and press Result The air purge starts It stops automatically when done To stop it manually press select OK and press 5 3 To perform a test run 1 Go to A 7 1 Installer settings Commissioni...

Page 18: ...Fill in the installer setting table in the operation manual with the actual settings Make sure that the user has the CD DVD and the printed documentation and ask him her to keep it for future reference Explain the user how to properly operate the system and what he she has to do in case of problems Show the user what jobs he she has to do in relation to maintenance of the unit Explain the user abo...

Page 19: ...ter pulse input 2 electrical meter pulse input 1 preferential kWh rate PS contact external indoor or outdoor ambient thermistor domestic hot water thermistor external sensor floor or ambient ambient sensor On OFF thermostat thermal protector booster heater 6T1 3 230 V 6 kW 9WN 3N 400 V 9 kW 6WN 3N 400 V 6 kW 6V3 1N 230 V 6 kW 3V3 1N 230 V 3 kW Backup heater configuration only for 9W Ext thermistor...

Page 20: ...230 V 6 kW for 3V3 1N 230 V 3 kW only for 9W only for 3V only for KHWS V3 domestic hot water tank 4D077028 page 3 A4P YC A4P Y2 A4P Y2 X2M 29 S6S S7S S8S S9S S3S BSK S1S S2S B1L X2M 14 X2M 9 X2M 14 X2M 9 X2M 13 t R5T t R6T 2 KHR KHUR KCR KFR t R1T t R1T 2 X18A 1 2 X22A 1 X85A 1 2 3 4 5 6 t R1T F1U F2U 3 CN1 1 6 5 4 3 2 CN2 1 X80A 1 2 7 8 4 X4A 1 2 3 X33A 1 3 4 6 5 3 4 5 6 7 8 9 12 11 10 X40A 1 2 3...

Page 21: ...nly for 16 DHW pump 3 wire type SPST NO valve only for domestic hot water option 3 wire type SPDT domestic hot water tank only for enamel tank option only for domestic hot water option 1N 50 Hz 230 V AC Normal kWh rate power supply only for domestic hot water tank option A1P Main PCB A2P User interface PCB A3P Solar pump station PCB A3P On OFF thermostat PC power circuit A3P Heat pump convector A4...

Page 22: ...heater configuration only for 9W User installed options User installed options Bottom plate heater Bottom plate heater Domestic hot water tank Domestic hot water tank Domestic hot water tank with solar connection Domestic hot water tank with solar connection Remote user interface Remote user interface Ext indoor thermistor Extended indoor thermistor Ext outdoor thermistor Extended outdoor thermist...

Page 23: ...core signal Changeover to ext heat source output Ext heat source eg boiler Only for KRP1HB KSOLHWAV1 NO valve X2M 6 7 NC valve X2M 5 7 2 core 2WAY VALVE M2S KHBX units for cooling mode main X2M 1 2 4 add X2M 1a 2a 4 3 core for C H operation 2 core for H only operation main X2M 1 2 3 4 add X2M 1a 2a 3 4 main X2M 1 4 add X2M 1a 4 4 core Only for KRTW wired room thermostat Only for KRTR wireless room...

Page 24: ... pulse kWh 1pulse kWh 10pulse kWh 100 pulse kWh 1000 pulse kWh pulse duration minimum On time 40ms minimum OFF time 100ms measurement type depending on installation single phase AC meter three phase AC meter balanced loads three phase AC meter unbalanced loads electrical meter installation guideline General it is the reponsability of the installer to cover the complete power consumption with elect...

Page 25: ...Notes_1 fm Page 1 Tuesday December 4 2012 2 51 PM ...

Page 26: ...Notes_1 fm Page 1 Tuesday December 4 2012 2 51 PM ...

Page 27: ...Notes_1 fm Page 1 Tuesday December 4 2012 2 51 PM ...

Page 28: ...4P313771 1C 2012 11 Copyright 2012 Daikin ...

Reviews: