Daikin EDLQ036BA6VJU1 Operation Manual Download Page 7

EDLQ036~054B EBLQ036~054BA6VJU1

Unit for air to water heat pump system

4PW56183-1

Operation manual

6

Controller operations

Manual operation

In manual operation, the user manually controls the settings of the
installation. The last setting remains active until the user changes it or
until the schedule timer forces another setting (refer to "Schedule
timer operation" on page 7).

As the controller can be used for a wide variety of installations, it is
possible to select a function which is not available on your
installation. In that case the message 

n

 will appear.

Switching on and setting space cooling (

c

) and heating (

h

)

1

Use the 

=

 button to select space cooling (

c

) or space heating (

h

).

Icon 

c

 or 

h

 appears on the display as well as the corresponding

water temperature set point.

2

Use the 

bi

  and 

bj

  buttons to set the desired water

temperature.

Temperature range for heating: 77°F to 131°F (25°C to 55°C)
The temperature for heating can be set as low as 59°F
(15°C) (see "Field settings" on page 11). However, the
temperature for heating should only be set lower than 77°F
(25°C) during commissioning of the installation. When set
lower than 77°F (25°C), only the backup heater will operate.
In order to avoid overheating, space heating is not operable
when the outdoor ambient temperature rises above a certain
temperature (as set through field setting [4-02], refer to "Field
settings" on page 11).

Temperature range for cooling: 41°F to 72°F (5°C to 22°C)

3

Switch on the unit by pushing the 

y

 button.

The operation LED 

0

 lights up.

Selection and setting of domestic water heating (

w

)

1

Use the 

v

 button to activate domestic water heating (

w

).

Icon 

w

 appears on the display.

2

Use the 

wi

  or 

wj

  button to display the actual

temperature set point and subsequently, to set the correct
temperature.

The actual temperature set point only appears on the display
after pressing one of the buttons 

wi

 or 

wj

. If no button is

pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating: 86°F to 172°F
(30°C to 78°C)

3

Press the 

v

 button to deactivate domestic water heating (

w

).

Icon 

w

 disappears from the display.

Selecting powerful domestic water heating operation

1

Press 

v

  for 5 seconds to activate powerful domestic water

heating operation.

Icons 

w

 and 

m

 start flashing.

Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.

Selecting quiet mode operation (

s

)

1

Use the 

s

 button to activate quiet mode operation (

s

).

Icon 

s

 appears on the display.

If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 11), the 

s

 button will not be operable.

Selecting weather dependent set point operation (only in
heating mode)

1

Press the 

ba

  button to select weather dependent set point

operation.

Icon 

a

  appears on the display as well as the shift value. The

shift value is not shown in case it is 0.

2

Use the 

bi

 and 

bj

 buttons to set the shift value.

Range for the shift value: –9°F to +9°F (–5°C to +5°C)

Displaying actual temperatures

1

Push the 

ba

 button for 5 seconds.

The 

b

 icon and the outgoing water temperature are displayed.

The icons 

l

 and 

=

 are flashing.

2

Use the 

pi

 and 

pj

 buttons to display:

The outdoor temperature (

u

 icon is flashing).

The domestic hot water tank temperature (

w

  icon is

flashing).

The outgoing water temperature (

=

 are flashing).

If no button is pressed for 5 seconds, the controller leaves the
display mode.

CAUTION

The actual operation range depends on the values set on
field setting [9].

These values shall be determined based on the
application.

NOTE

In heating mode (

h

), the water temperature set point

can also be weather dependent (icon 

a

 is shown).

This means that the controller calculates the water
temperature set point based on the outdoor temperature.

In this case, instead of showing the water temperature
set point, the controller shows the "shift value" which
can be set by the user. This shift value is the
temperature difference between the temperature set
point calculated by the controller and the real set point.
E.g. a positive shift value means that the real
temperature set point will be higher than the calculated
set point.

NOTE

When the unit is connected to an external room
thermostat, buttons 

=

 and 

y

 are not operable and

the icon 

e

  is shown. In this case, the external room

thermostat switches the unit on or off and determines
the operation mode (space cooling or space heating).

Remark that pushing the 

y

  button has no influence on

the domestic water heating. Domestic water heating is only
switched on or off by means of the 

v

 button.

1D_OM_4PW56183-1.book  Page 6  Monday, September 21, 2009  11:09 AM

Summary of Contents for EDLQ036BA6VJU1

Page 1: ...glish Manuel d utilisation Unit pour syst me de pompe chaleur air eau Fran ais Manual de operaci n Unidad para bomba de calor de aire agua Espa ol EDLQ036BA6VJU1 EDLQ048BA6VJU1 EDLQ054BA6VJU1 EBLQ036B...

Page 2: ...low temperature radiators domestic hot water tank option and solar kit option Heating cooling units and heating only units The monoblock unit range consists of two main versions a heating cooling EB...

Page 3: ...oom thermostat connected to the unit This will prevent excessive space heating and will stop the unit and the circulation pump when the room temperature is above the thermostat set point Next recommen...

Page 4: ...e icons indicate the current operation mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic wate...

Page 5: ...itching between cooling or heating mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat this button is not operable and the icon e is shown 26...

Page 6: ...hot water tank by heat pump when the space heating space cooling operation has reached its temperature set point or heat pump domestic water heating has a higher demand request than space side depends...

Page 7: ...r heating operation 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set...

Page 8: ...rogrammed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order t...

Page 9: ...set point Conversely when programming cooling actions time and setpoint heating actions are added automatically at the same time but with the default heating set point The set points of these automati...

Page 10: ...s to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the pr...

Page 11: ...m it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press the...

Page 12: ...e z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface buttons can be made unavailable for the user Three permission levels are defined see t...

Page 13: ...tus defines whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic water should be heated 2 03 Set point high water temperature to be reached 2...

Page 14: ...it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refer to the installation manual o...

Page 15: ...1 02 Start time 23 00 0 00 23 00 1 00 hour 03 Set point 158 70 104 176 40 80 9 5 F C 04 Interval 10 5 60 5 min 3 Auto restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation relate...

Page 16: ...Read only C Setup on EKRP1HB digital I O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation rela...

Page 17: ...ts must be done by a qualified installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensur...

Page 18: ...mestique option et au kit solaire option Unit s de chauffage refroidissement et unit s de chauffage uniquement La gamme des unit s monobloc consiste en deux versions princi pales une version chauffage...

Page 19: ...ge de locaux excessif et arr tera l unit et la pompe de circulation lorsque la temp rature ambiante d passe le point de consigne du thermostat Les recommandations suivantes s appliquent uniquement aux...

Page 20: ...a DEL clignote si un dysfonctionnement se produit Lorsque la DEL est teinte le refroidissement ou le chauffage de locaux est inactif pendant que les autres modes de fonctionnement peuvent toujours tre...

Page 21: ...NCTIONNEMENT TEST t Cette ic ne indique que l unit fonctionne en mode test Pri re de se r f rer au manuel d installation 23 CODE DE REGLAGE SUR PLACE Ce code repr sente le code de la liste des r glage...

Page 22: ...leur du syst me int rieur pour emp cher le gel du syst me ext rieur Apr s un maximum de 8 minutes en mode d givrage le syst me revient en mode chauffage de locaux Mode de refroidissement de locaux c D...

Page 23: ...e ment de l affichage Plage de temp rature pour le chauffage d eau domestique 86 F 172 F 30 C 78 C 3 Appuyer sur le bouton v pour activer le chauffage d eau domestique w L ic ne w dispara t de l cran...

Page 24: ...programm es 13h00 16h00 et 19h00 La derni re commande programm e 16 00 a supplant la commande programm e pr c dente 13 00 et restera active jusqu ce que la commande programm e suivante 19 00 se produi...

Page 25: ...efroidissement sont ajout es automatiquement en m me temps mais avec le point de con signe de refroidissement par d faut d fini Inversement lors de la programmation des actions de refroidissement dur...

Page 26: ...refroidissement et le chauffage de la commande 9 r gler la temp rature au moyen des boutons bi et bj a pour s lectionner le calcul de temp rature automatique uniquement en mode de chauffage 10 Utilise...

Page 27: ...ions de refroidissement ou de chauffage de locaux La consultation du refroidissement ou du chauffage de locaux s effectue comme suit 1 Utiliser le bouton pour s lectionner le mode de fonctionnement re...

Page 28: ...fonc lorsque le num ro d action 3 est affich les actions 1 2 et 3 sont sauvegard es mais 4 et 5 sont supprim es Suppression d un mode 1 Appuyer sur le bouton Le mode r el clignote 2 Utiliser les bouto...

Page 29: ...ultan ment sur le touches pfi et pfj puis en appuyant tout de suite apr s sur les touches s et ba et en maintenant les 4 touches enfonc es pendant au moins 5 secondes en mode normal A noter qu aucune...

Page 30: ...on S applique uniquement aux installations avec un ballon d eau chaude domestique La fonction de d sinfection d sinfecte le ballon d eau chaude domestique en chauffant p riodiquement l eau domestique...

Page 31: ...sup rieures sont requises Dans certains cas cela peut entra ner un fonctionnement moins silencieux de l unit pour satisfaire aux performances requises A 00 Type de mode discret d finit si le mode disc...

Page 32: ...t 1 ON 0 1 02 Heure de d but 23 00 0 00 23 00 1 00 heure 03 Point de consigne 158 70 104 176 40 80 9 5 F C 04 Intervalle 10 5 60 5 min 3 Red marrage automatique 00 Statut 0 ON 0 1 4 Temp rature d arr...

Page 33: ...ecture seule 04 Ne s applique pas 0 Lecture seule C Configuration sur la carte d E S num rique EKRP1HB 00 R glage du mode de priorit solaire 0 0 1 1 01 R glage relatif l installation 02 R glage relati...

Page 34: ...e utilisation car ces tuyaux peuvent tre chauds Il y a un risque de br lures aux mains Pour viter des blessures laisser le temps aux tuyaux de revenir une temp rature normale ou veiller porter des gan...

Page 35: ...in s s par ment des ordures m nag res non tri es Ne pas essayer de d monter vous m me l appareil le d montage du syst me ainsi que le traitement du r frig rant de l huile et d autres composants doiven...

Page 36: ...ia opcional y kit solar opcional Unidades de s lo calefacci n refrigeraci n La gama de unidades monobloque consta de dos versiones princi pales una versi n de calefacci n refrigeraci n EB y una versi...

Page 37: ...termostato en la estancia conectado a la unidad As se evitar el exceso de calefacci n del espacio interior y se har parar la unidad y la bomba de circulaci n cuando la temperatura de la estancia sea...

Page 38: ...do de calefacci n o el modo de refrigeraci n est n inactivos mientras el resto de los modos de funcionamiento pueden permanecer activados 3 ICONOS DEL MODO OPERATIVO hcws Estos iconos indican el modo...

Page 39: ...C DIGO DE AJUSTE DE OBRA Este c digo representa el c digo de la lista de ajustes de obra Consulte el manual de instalaci n 24 C DIGO DE ERROR Este c digo procede de la lista de c digos de error y s l...

Page 40: ...anitaria es posible que se congele el intercambiador de calor externo debido a las bajas temperaturas exteriores Si esto sucede se activar el modo de desescarche del sistema Esta funci n invertir el c...

Page 41: ...l agua sanitaria w 1 Pulse el bot n v para activar el modo de calentamiento del agua sanitaria w El icono w aparecer en la pantalla 2 Pulse el bot n wi o wj para mostrar la temperatura de referencia a...

Page 42: ...iariamente Qu posibilidades NO ofrece el programador El temporizador de programaci n no puede cambiar el modo de funcionamiento de refrigeraci n a calefacci n o viceversa C mo interpretar las acciones...

Page 43: ...de referencia las acciones de calefacci n se a aden autom tica mente al mismo tiempo pero con el punto de referencia de calefacci n predefinido por defecto Los puntos de referencia de estas acciones a...

Page 44: ...eraci n y el de calefacci n y apagar el controlador 9 ajuste la temperatura mediante los botones bi y bj a para seleccionar el c lculo autom tico de temperatura s lo en modo calefacci n 10 Pulse los b...

Page 45: ...geraci n o calefacci n La consulta del modo de refrigeraci n o de calefacci n se realiza del siguiente modo 1 Pulse el bot n para seleccionar el modo de funcionamiento refrigeraci n o calefacci n que...

Page 46: ...1 Pulse el bot n El modo real parpadea 2 Pulse los botones pi y pj para seleccionar el modo que desee borrar modo susurrante s resistencia el ctrica m o calentamiento de agua sanitaria w El modo sele...

Page 47: ...mult neamente inmediatamente seguido por los botones s y ba durante al menos 5 segundos en modo normal Tenga presente que no se proporciona ninguna indicaci n en la interfaz de usuario Cuando el nivel...

Page 48: ...eraturas exteriores m s c lidas Hi_A se requiere menos agua caliente 2 Funci n de desinfecci n S lo disponible en las instalaciones con dep sito de agua caliente sanitaria La funci n de desinfecci n d...

Page 49: ...nsecuencia un bajo rendimiento En el modo susurrante B podr a anularse el funcionamiento a bajo nivel de ruido cuando se requiera un rendimiento superior En determinados casos esto podr a tener como c...

Page 50: ...ejemplo 23 E 02 Lectura de la identificaci n de modelo de la unidad ejemplo 11 E 03 Lectura de la temperatura del refrigerante l quido E 04 Lectura de la temperatura del agua a la entrada NOTA Las lec...

Page 51: ...e ajuste punto de referencia 158 70 104 176 40 80 9 5 F C 04 Intervalo 10 5 60 5 min 3 Reinicio autom tico 00 Estado 0 ON 0 1 4 Temperatura de calefacci n de habitaciones OFF 00 Ajuste relacionado con...

Page 52: ...P1HB 00 Ajuste del modo de prioridad solar 0 0 1 1 01 Ajuste relacionado con la instalaci n 02 Ajuste relacionado con la instalaci n 03 Ajuste relacionado con la instalaci n 04 Ajuste relacionado con...

Page 53: ...de agua durante ni inmediata mente despu s de la operaci n porque pueden estar calientes Puede sufrir quemaduras en las manos Para evitar lesiones deje que las tuber as vuelvan a su temperatura normal...

Page 54: ...esiduos dom sticos no clasificados No intente desmontar el sistema usted mismo El desmantelamiento del sistema as como el tratamiento del refrigerante aceite y otros componentes debe ser efectuado por...

Page 55: ......

Page 56: ...DAIKIN AIR CONDITIONING AMERICAS 1645 Wallace Drive Suite 110 Carrollton TX 75006 Copyright Daikin 4PW56183 1...

Reviews: