PIM00587
EN-51
10.4
Monitor Mode
10.4.1
List of display items in the monitor mode
The monitor mode enables monitoring of the items listed in the table below by selection.
Monitor No.
Name
Unit
Details
n00
Pressure switch set value
MPa
Displays the value set with the pressure switch.
10 PSI
n01
Pressure set value
MPa
Displays the pressure setting value of the current P-Q selection
number.
10 PSI
n02
Flow rate set value
L/min
Displays the flow rate setting value of the current P-Q selection
number.
n03
Flow rate
L/min
Displays the current flow rate.
n04
Latest alarm code
–
Displays the alarm code for the alarm that occurred immediately
previously.
By pressing the
key, the current power-on count can also
be checked.
n05
Motor rotation speed
10 min
-1
Displays the current rotational speed of the motor.
n06
Running status display
–
Displays the P-
Q selection number. “L” is a fixed sign.
Example:
PQ selection No. 0
n07
Reverse rpm at power-
OFF
min
-1
Displays a motor reverse rpm due to counter-flow from the load
when the unit power supply is turned OFF. This parameter is
used to estimate the machine load volume.
n08
Regenerative load
integration ratio
%
Displays the load integration ratio of the current regenerative
braking resistance.
n09
(Reserved for the system)
–
Reserved for the system.
n10
Motor temperature
C
Displays the motor temperature.
n11
Radiating fin temperature
C
Displays the temperature of the radiating fins.
n12
Main circuit DC voltage
V
Displays the direct current voltage of the controller’s main circuit.
The voltage value is the supply power voltage multiplied by the
square root of 2, and it varies depending on the running status.
n13
Analog input voltage 1
V
Displays the input voltage of the analog input terminal AIN1.
Displayed only for models with the analog communications
option (-P) in their model designation.
n14
Analog input voltage 2
V
Displays the input voltage of the analog input terminal AIN2.
Displayed only for models with the analog communications
option (-P) in their model designation.
n15
Analog output voltage 1
V
Displays the output voltage of the analog output terminal AO1.
Displayed only for models with the analog communications
option (-P) in their model designation.
n16
Analog output voltage 2
V
Displays the output voltage of the analog output terminal AO2.
Displayed only for models with the analog communications
option (-P) in their model designation.
n17 to n19
(Reserved for the system)
–
Displays “0”.
n20
Power-on count
(lower digits)
Times
Displays the number of times the unit has been powered on after
shipment from the factory.
(On exceeding a count of 9,999, the value is cleared to 0.)
n21
Power-on count
(upper digits)
1000
times