6.3
Securing the Hydraulic Unit
Secure the hydraulic unit on a level platform, or a floor, that will not be affected by the vibration of the main
machine.
For details on the mounting method and position, refer to the Delivery Specification (outline drawing).
Motor pump type (EHU15/30R**00*-03)
20L tank unit type (EHU15/30R**02)
Installation Mounting Hole Dimensions
490
314
4-
φ
10 (M8 bolts recommended)
Installation Mounting Hole Dimensions
Oil filling / drain port
4 -
φ
10 holes
(
▲
positions
: M8 bolts recommended)
436
■
(
φ
13 holes
)
▲
▲
■
■
435
▲
(
φ
10 holes
)
5
4
.5
240
309
37
4 -
φ
13 holes
(
■
positions
: M10 bolts recommended)
20
5
▲
▲
■
■
11