Installation servicing space
(C) In case of multiple-row installation (for roof top use, etc.)
In case of installing one unit per row.
The numerical
figures used in the figures represent the dimensions in
mm.
(Refer to "Precautions on installation" on page 5)
Precaution
(A) In case of non-
stacked installation figure 1A and figure 1B
≥4 inch (≥100
mm)
Suction side obstacle
Obstacle is present
≥80 inch (≥2000
mm)
≥8 inch (≥200
mm)
Discharge side obstacle
In these cases, close the
bottom of the installation
≥40 inch (≥1000
mm)
Left side obstacle
frame to prevent the
discharged air from
being bypassed
In case of installing multiple units (2 units or more) in lateral
connection per row.
Right side obstacle
In these cases, only
2 units can be installed.
Top side obstacle
This situation is not
allowed
NOTE
Minimum distance B1 in figure 1A and figure 1B
L
mentions the space required for correct operation
of the unit. Required space for servicing though is
12 inch (300 mm).
≥120 inch (≥3000
mm)
(B) In case of stacked installation
≥24 inch (≥600
mm)
≥60 inch (≥1500
mm)
In case obstacles exist in front of the outlet side.
Relation of dimensions of H, A and L are shown in the table below.
L
A
A
L≤H
0<L≤1/2H
1/2H<L
10 (250)
12 (300)
≥40 inch (≥1000
mm)
In case obstacles exist in front of the air inlet.
A
≥12 inch (≥300
mm)
Do not stack more than one unit.
About 4 inch (100 mm) is required as the dimension for laying the
upper unit's drain pipe. Get the portion A sealed so that air from the
outlet does not bypass.
H<L
Installation not allowed
Installation manual
EDLQ036~054B EBLQ036~054BA6VJU1
Unit for air to water heat pump system
4PW56182-1