Description
The Daikin
One
Premium
Air Cleaner is an in-line air cleaner that
treats home air for airborne particulate matter and chemicals found
in the home. The high efficiency MERV 15 media filter removes more
than 85% of particles down to 0.3 microns in size at rated flow.
The Daikin
One
Premium Air Cleaner also includes a room temperature
catalyst (RTC) insert that helps remove formaldehyde, ozone, and other
chemicals from the air stream.
Proprietary Notice
This document and the information disclosed herein are
proprietary data of Daikin North America LLC. Neither this
document nor the information contained herein shall
be reproduced, used, or disclosed to others without the written
authorization of Daikin North America LLC, except to the extent
required for installation or maintenance of recipient’s equipment.
Copyright Notice
Copyright 2021, Daikin North America LLC All rights reserved.
Specifications
WARNING!
This symbol indicates important instructions. Failure to heed
them can result in serious injury or death.
i
WARNING!
This air cleaner utilizes very strong magnets to fasten the
cabinet door. Magnets may interfere with pacemakers and
Implantable Cardiac Defibrillators (ICDs).
i
WARNING!
Do not ingest magnets; ingested magnets can cause serious
intestinal injury.
i
WARNING!
Before beginning any installation or modification, be certain
that the main line electrical disconnect switch is in the OFF
position. Unexpected start-up of system blower may cause
serious injury. Tag disconnect switch with suitable
warning labels.
i
CAUTION!
This symbol indicates important instructions. Failure to heed
them can result in injury or material property damage.
i
CAUTION!
Installation:
• Only trained personnel should install this unit (see warning
on cover page).
• Homeowners can perform the basic maintenance functions
of replacing filters.*
i
Read and save these instructions.
Important: Read and save these instructions. This guide to be left with equipment owner.
i
Handling, Storage and Disposal of
Replacement Filters.
Storage of Replacement Room Temperature Catalyst Insert
When working on the air cleaner, observe precautions in the Owner’s
Manual labels attached to the furnace or air handler, and other safety
precautions that may apply.
• Always use personal protective equipment that is clean and has
been properly maintained.
• Always use safety glasses
• Always use work gloves that is resistant to chemical agents
-
Recommended Natural latex.
• Always use disposable half-mask dust filter.
• Avoid contact with eyes.
• Avoid skin contact.
• Avoid breathing dust.
• Never eat, drink or smoke in the area where you are replacing
the filters.
• Always wash hands and face thoroughly after handling.
Replacement Filters
Air Cleaner
Model
(1)
Replacement
MERV15 Filter
(2)
Replacement
Room Temperature
Catalyst (RTC)
(2)
DV1-15-2117-AB
0160M00013
DVFC-AB
DV1-15-2121-AC
0160M00014
DVFC-AC
DV1-15-2124-AD
0160M00015
DVFC-AD
DV1-15-2814-FA
0160M00016
DVFC-FA
DV1-15-2817-FB
0160M00017
DVFC-FB
DV1-15-2821-FC
0160M00018
DVFC-FC
DV1-15-2824-FD
0160M00019
DVFC-FD
Filter should be changed once or twice a year based on conditions within the home.
RTC should be changed once every six months based on conditions within the home.
(1)
EPA EST. NO. 073316-TEX-001 •
(2)
EPA EST. NO. 71027-MEX-001
WARNING!
Risk of Carbon Monoxide. Do not use this air
cleaner without the cabinet door installed. If the
cabinet ddoor is not installed, there is a risk that
exhaust fumes may be drawn into occupied spaces, which can
cause injury or death.
i
i
CAUTION!
This air cleaner utilizes industrial strength magnets. Hold front
door panel with both hands when removing or replacing door
to avoid pinching fingers between door and cabinet.
i
CAUTION!
Potassium iodide exposure may cause skin irritation, serious
eye irritation and damage to organs through prolonged or
repeated exposure (if swallowed). Do not breathe dust/fume/
gas/mist/vapours/spray.
• If on skin; Remove contaminated clothing and wash the skin
thoroughly with water
-
If the contaminated area is widespread and/or there is
damage to the skin, seek medical attention.
• If in eyes; Rinse thoroughly with fresh, clean water holding the
eyelids open. Remove contacts lenses, if present and easy to do.
Continue rinsing.
• If there is any redness, pain or visual impairment, consult an
ophthalmologist.
• In an event of swallowing, seek medical attention immediately.
Do NOT give the patient anything orally. If the swallowed quantity
is small (no more than one mouthful), rinse the mouth with water
and consult a doctor.
*See Handling, Storage and Disposal of Replacement Filters