background image

4

www.daikincomfort.com

IO-DOPAC

IO-DOPAC

www.daikincomfort.com

5

Dual filter furnace application, side return (For any 

side return on a furnace without a furnace riser, 

use one DV1-15-2817-FB on A & B or two  

DV1-15-2817-FB on C & D furnace sizes)

 

Furnace Riser

Duct transition for side flow dual filter installation furnace/air handler application

Duct transition

D

uc

tw

ork

D

uc

tw

ork

D

uc

tw

ork

Turning  

Vanes

Turning  

Vanes

Single filter furnace application, side return  

with furnace riser (When using a furnace riser,  

use DV1-15-2824-FD on all furnace sizes)

Turning  

Vanes

D

uc

tw

ork

Riser

Furnace Riser

Specifications

MODEL

DV1-15-2117-AB DV1-15-2121-AC DV1-15-2124-AD DV1-15-2814-FA DV1-15-2817-FB DV1-15-2821-FC DV1-15-2824-FD

Airflow - up to  

maximum rated flow

Up to 1200 cfm 

(2039 m

3

/h)

Up to 1600 cfm 

(2718 m

3

/h)

Up to 1800 cfm 

(3058 m

3

/h)

Up to 1200 cfm 

(2039 m

3

/h)

Up to 1600 cfm 

(2718 m

3

/h)

Up to 2000 cfm 

(3398 m

3

/h)

Up to 2000 cfm 

(3398 m

3

/h)

Duct Size

21 x 17 in 

(53 x 43 cm)

21 x 21 in 

(53 x 53 cm)

21 x 24 in 

(53 x 61 cm)

28 x 14 in 

(71 x 36 cm)

28 x 17 in 

(71 x 43 cm)

28 x 21 in 

(71 x 53 cm)

28 x 24 in 

(71 x 61 cm)

Pressure Drop* 

(Filters Only)

0.11 in. w.g. 

@ 600 cfm

0.11 in. w.g. 

@ 800 cfm

0.11 in. w.g. 

@ 900 cfm

0.10 in. w.g. 

@ 600 cfm

0.10 in. w.g. 

@ 800 cfm

0.10 in. w.g. 

@ 1000 cfm

0.08 in. w.g. 

@ 1000 cfm

0.26 in. w.g.  

@ 1200 cfm

0.31 in. w.g.  

@ 1600 cfm

0.27 in. w.g.  

@ 1800 cfm

0.27 in. w.g.  

@ 1200 cfm

0.26 in. w.g.  

@ 1600 cfm

0.24 in. w.g.  

@ 2000 cfm

0.19 in. w.g.  

@ 2000 cfm

MERV Rating*

15

15

15

15

15

15

15

Notes: 

1.  Installation with units with ECM motors recommended.

 

2. Two filters should be considered for any airflow rates above maximum rated flow or when duct pressure loss is excessive.

Furnace Size

A

B

C

D

Furnace Riser

AMP-BSRB-1428

AMP-BSRB-1728

AMP-BSRB-2128

AMP-BSRB-2428

When using a furnace riser use DV1-15-2824-FD on all size furnaces 
MERV Rating 15 - Minimum Filtration Efficiency @492 fpm: • E1 85% (0.3 - 1.0 micron) • E2 90% (1.0 - 3.0 micron) • E3 95% (3.0 - 10.0 micron)

*Independent testing performed by LMS Technologies, Inc. Specification values may vary due to individual systems.

Filter Match-up Options

Air Handler Filter Options

Furnace Filter Options

Air Handler Size Bottom/Top Return Plenum Return

Furnace Size Bottom/Top Return Side Return

Side Return with Furnace Riser

B

21x17

21x21

A

28x14

28x17

28x24

C

21x21

21x24

B

28x17

28x17

28x24

D

21x24

21x24

C

28x21

(2) 28x17

28x24

D

28x24

(2) 28x17

28x24

Reviews: