72
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
DP14GM61***43A*
ECON
ECONOMIZE
R
G
ECON
ECON
ECON
ECON
5
6
2
4
1
BL
PU
PU
YL
BL
2
1
3
5
4
6
FAN CAPACI
T
O
R
014
0G0
4455
-B
FAC
T
ORY WIRIN
G
SOLE
NOID (
2ND S
T
AGE COO
L
)
SOL
FC
FUSE
F
VEN
T MOT
O
R
VM
CO
MPRESSOR
CO
MP
LINE VO
L
TAGE
OPTI
O
NA
L HI
GH VO
L
T
AGE
HIGH VO
L
T
AGE
FIELD
WI
RING
LO
W
VO
LT
AGE
LO
W
VO
L
TAGE
BK BLACK
WI
RE CO
DE
PK PINK
OR ORA
NGE
GR GRE
EN
BR BRO
W
N
BL B
LUE
RD RED
WH
W
H
IT
E
YL
YELLO
W
PU PURP
L
E
ALS
CC
CM
CO
MP
ONEN
T
LE
GEND
CONT
A
CT
OR
CONDENSER MOT
OR
AUXIL
LA
RY LIMI
T
S
W
IT
CH
GAS VA
LVE
GV
FS
GND
IGNIT
OR
PS
LS
IGN
IIC
EQUIP
MENT GROUND
PRESSUR
E S
W
IT
CH
LIMI
T S
W
ITCH
INT
EGRA
T
ED IGNITI
ON CON
T
ROL
FLA
ME SENS
OR
TR
T
RANSFORMER
ROL
L
OUT S
W
IT
CH
RS
EM
EVAPOR
AT
OR MOT
O
R
NOTES
1. REP
L
A
CEME
N
T
WI
RE MUST BE
T
HE SAME SIZE AN
D TYPE OF
INSULA
T
ION AS O
RIGINA
L.(USE
COPPE
R
CONDUC
T
OR O
NLY).
2. FOR
20
8 V
O
L
T
T
RANSFORMER OPERATI
O
N
MOVE BLA
CK WI
RE
FROM T
ERMINAL
3 T
O
T
ERMINAL
2 O
N
T
RANSFORME
R
.
3. USE C
OPPER C
ONDUC
T
ORS O
NLY
4. FOR
20
8V
OPERA
T
ION, REMOVE BL
UE LE
AD FROM INDU
CER
L
O
W
TER
MINA
L. M
OVE B
L
A
CK LE
AD FRO
M PARK
T
E
RMINAL ONT
O
INDUCER L
O
W
T
ERMINAL. P
L
A
CE BL
UE LE
AD ON PARK
TERMINAL.
5. USE N
EC CLASS
2
WI
RE FOR T
HERMOST
AT FIE
LD
WI
RING.
6. C
OMPRESSOR 2
ND S
T
AGE SO
LENOID NO
T P
RESEN
T
ON A
L
L
MODELS.
7. FOR E
CONOMIZE
R, REMOVE P
LUG FRO
M EC
ONOMIZE
R
HARNESS.
CONNEC
T
P
LUG FRO
M
ECONOMIZE
R
T
O
HAR
NESS.
HI CO
OL
L
O
CO
OL
HI HEAT
L
O
HEAT
P2
MVC
MVH
MVL
PS
W
PS
W
HLO
TH
2
3
5
6
4
1
5
7
9
8
6
3
1
2
HI
LO
HI
SO
L
GV
T4
T1
T3
T2
EM
C
CC
C
HI
M
RS
PS
LS
ALS
TR
EM
VM
L2
T2
20
8-2
3
0/
3/6
0
CM
L1
T2
T1
T3
COMP
T1
SUPPLY VOL
T
AGE
P1
CC
CC
COM
HLI
SEE NO
T
E
2
INTERGRATED IGNITION
CONTROL
F
Y1
R
C
Y2
W2
W1
TO
MICR
O
TO
MICR
O
LO
SEE NOTE 6
YL
RD
OR
BK
BK
RD
BL
PU
PU
PU
PU
OR
BR
WH
BL
BK
PU
BL
IGN
OR
LS
SOL
HI
LO
W
ODF
L1
HIGH
FS
T1
LO
W
INDUCER
L2
BK
RD
GR
SEE NO
T
E
3
EM
20
8
PU
YL
PU
BK
NG
L
T5
T4
T3
T2
T1
240
3
TR
2
RD
24
V
C
1
YL
BL
2
0
8
-2
3
0/3/
6
0
POW
ER SUPPLY
GND
C
PU
PU
RD
BK
BR
PU
BK
T2
T3
COMP
T1
T2
T1
CC
L2
L1
ALS
CM
LPS
HPS
SO
L
PARK
BK
PU
ODF
OUT
DOOR FAN
HPS
LPS
SEE NOT
E 3
1
2
3
SEE NO
T
E
2
BL
BK
SEE
NOT
E
7
HIGH PRE
SSURE S
W
IT
CH
HPS
LPS
L
O
W PRESSUR
E
S
W
IT
CH
SEE NOT
E 2
YL
YL
YL
YL
YL
YL
YL
YL
YL
PU
F
WH
BR
YL
BL
OR
OR
YL
PU
BR
BL
BR
PU
PU
YL
NO
NE
5 M
IN
10 M
IN
180
150
120
90
Y2
Y1
G
W2
W1
BL
O
W
E
R
OF
F DE
LA
Y
ST
AG
E
DE
LA
Y
ECON
LO HEA
T
HI HEAT
HI CO
O
L
L
O
CO
OL
C
H
M
PU
C
F
RD
BR
FC
RD
GV
GAS VA
LVE
W. R.
BK
2
4VA
C COM
PU
5
4
3
2
1
1
2
3
4
5
6
7
8
9
P1
RD
BL
BL
P2
5
4
2
1
3
6
YL
YL
YL
YL
BK
VM
RD
YL
PU
BL
BR
BR
YL
PS
YL
YL
RS
OR
OR
FS
RD
PU
BK
BL
EQUIPMENT GROU
N
D
FI
ELD GROUND
FI
ELD S
P
L
ICE
SW
ITCH (TEM
P
)
IGNIT
E
R
S
W
ITCH (PRESS.)
OVER
CU
R
RENT
PROT.
DEVICE
JUN
CTION
TERM
INAL
INTERNAL T
O
INTEGRATED CONTROL
PLUG CONNE
CTION
SEE NOTE 7
SEE NO
T
E
5
SEE NOTE 5
RE
PLAC
E C
ONTRO
L
3
M
IN C
O
M
P
. SH
ORT
CYC
LE DELAY
C
OMPR
. SH
ORT CYC
L
E DELAY
6 F
LASHES
D
IA
GN
OS
T
IC
LED
- RED
CHE
C
K
F
OR
SHORT
S
IN
FLA
M
E SENSOR
W
IR
IN
G
CHE
C
K G
AS
VA
LVE
CHE
C
K
ROLLOUT
LI
MI
T
SW
.
CHE
CK
AUX
ILI
ARY
LI
MI
T SW
.
CHE
CK
M
A
IN
LI
M
IT SW
IT
C
H
CHE
CK W
IR
IN
G
F
OR
SH
ORTS
CH
EC
K PRESSUR
E
S
W
ITCH
PRESSUR
E
S
W
ITCH C
L
OSED
CHE
CK VEN
T
M
O
T
O
R
CHE
C
K
TUB
IN
G
CHE
CK FU
SE(S)
CHE
CK
I
NPU
T
POW
E
R
-
GAS PRESSURE
FLA
M
E SENSOR
GAS VA
LVE
GAS FLOW
CH
ECK PRES
SUR
E S
W
ITCH
OFF
ON
1 F
L
AS
H
3 FLASHE
S
2 FLASHE
S
4 FLAS
HES
5 FLASHE
S
FA
LSE FLA
M
E
DE
T
ECTED
OP
E
N
L
IMI
T
S
W
IT
CH
W
ITHO
U
T I
NDUC
ER
ON
PRESSUR
E
S
W
ITCH OPEN
IG
N
ITI
ON FA
IL
URE
N
O
R
M
A
L
OPERATI
ON
NO
P
O
W
E
R
OR
INTERN
A
L
CONTR
O
L
FAU
LT
ST
A
T
U
S
CHE
CK
CHE
C
K
FOR
SHORTS
IN
FLA
M
E SE
NSOR W
IR
IN
G
-
N
O
R
M
A
L
FLA
M
E
PR
ESENT
DI
AG
NO
ST
IC
LED - AM
BER
-
G
AS PRESSURE
F
L
A
M
E SENSOR
G
A
S VA
LVE
GA
S
F
L
O
W
CH
EC
K GAS VA
LVE
ON
OF
F
1 FLASH
2 FLASHE
S
FA
LSE FLA
M
E
DE
T
E
CT
ED
LO
W
F
L
A
M
E
S
IGNAL
N
O
F
L
A
M
E
PRESENT
ST
AT
U
S
CHE
CK
PS
W
/LOC OPEN
9 FLASHES
CHE
CK JU
M
PER BET
W
EEN 1
AND
4
ON
6-CI
RCU
IT
C
ONNE
CTOR
ID
T/
ODT OPE
N
8 FLASHE
S
CHE
CK AUX
ILI
AR
Y
LI
M
IT
S
W
.
CHE
CK
MA
IN
LI
MI
T
SW
ITCH
LI
M
IT OPEN
5 T
IMES
IN
SAME
CALL FOR
H
EAT
DIA
G
NO
ST
IC
LED
- RED
7 FLASHE
S
ST
AT
U
S
CHE
C
K
CHE
CK O
P
T
IONAL
RE
FR
IGER
ANT SW
ITCHE
S
CHE
CK
RE
FR
IGER
ANT
S
W
ITCHES F
OR LOSS OF
CHA
R
GE OR H
IGH H
EAD
PRESSUR
E
T3
L3
L3
T3
CC
FC
9
8
7
9
RD
GR
R
C