WIRING DIAGRAMS
67
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
DP14GM[60/61]***41A*
G
RUN CAPACITOR FOR COMPRESSOR/FAN
0140G04497-A
FACTORY WIRING
SOLENOID (2ND STAGE COOL)
SOL
RCCF
FUSE
F
VENT MOTOR
VM
COMPRESSOR
COMP
LINE VOLTAGE
OPTIONAL HIGH VOLTAGE
HIGH VOLTAGE
FIELD WIRING
LOW VOLTAGE
LOW VOLTAGE
BK BLACK
WIRE CODE
PK PINK
OR ORANGE
GR GREEN
BR BROWN
BL BLUE
RD RED
WH WHITE
YL YELLOW
PU PURPLE
ALS
CC
CM
COMPONENT LEGEND
CONTACTOR
CONDENSER MOTOR
AUXILLARY LIMIT SWITCH
GAS VALVE
GV
FS
GND
IGNITOR
PS
LS
IGN
IIC
EQUIPMENT GROUND
PRESSURE SWITCH
LIMIT SWITCH
INTEGRATED IGNITION CONTROL
FLAME SENSOR
TR
TRANSFORMER
ROLLOUT SWITCH
RS
EM
EVAPORATOR MOTOR
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. USE COPPER CONDUCTORS ONLY
4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW
TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO
INDUCER LOW TERMINAL. PLACE BLUE LEADON PARK TERMINAL.
5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING.
6. COMPRESSOR 2ND STAGE SOLENOID NOT PRESENT ON ALL MODELS.
HI COOL
LO COOL
HI HEAT
LO HEAT
P2
MVC
MVH
MVL
PSW
PSW
HLO
TH
2
3
5
6
4
1
5
7
9
8
6
3
1
2
L1
L1
HI
LO
HI
SOL
GV
T4
T1
T3
T2
EM C
CC
C
HI
M
RS
PS
LS
ALS
TR
EM
VM
H
F
RCCF C
L2
T2
208-230/1/60
CM
L1
R
T1
S
COMP
C
L1
SUPPLY VOLTAGE
P1
IN
T
E
G
R
A
T
E
D
IG
N
IT
IO
N
C
O
N
T
R
O
L
CC
CC
COM
HLI
SEE NOTE 2
IN
T
E
RG
RA
T
E
D
IG
N
IT
IO
N
CO
NT
RO
L
F
Y1
R
C
Y2
W2
W1
TO
MICRO
TO
MICRO
IN
T
E
GR
A
T
ED
I
G
NI
T
ION
CON
T
RO
L
L1
LO
L2
L2
L2
L2
SOL
ODF
OUTDOOR FAN
HPS
LPS
1
2
3
HIGH PRESSURE SWITCH
HPS
LPS
LOW PRESSURE SWITCH
EQUIPMENT GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
JUNCTION
TERMINAL
INTERNA L TO
INTEGRATED CONTROL
PLUG CONNECTION
SE
E
N
O
T
E 5
REPLACE CONTROL
3 MIN COM P. SHO RT
CYC LE DELAY
COMPR . SHO RT CYCLE D ELAY
6 FLASHES
DIAGNOSTIC
LED - RED
CHECK FOR SHO RTS IN
FLAME SENSOR W IRING
CHECK GAS VALVE
CHECK ROLLOUT LIMIT SW .
CHECK AUXILIARY LIMIT SW .
CHECK MAIN L IMIT SW ITCH
CHECK W IRING FOR SHO RTS
CHECK PRES SURE SW ITCH
PRESSURE SW ITCH CLO SED
CHECK VENT MO TOR
CHECK TUBING
CHECK FUSE(S)
CHECK INPUT POW ER
-
GAS PRES SURE
FLAME SENSOR
GAS VALVE
GAS FLOW
CHECK PRESSURE SW ITCH
OFF
ON
1 FLASH
3 FLASHES
2 FLASHES
4 FLASHES
5 FLASHES
FALSE FLAME DETECTED
OPEN LIMIT SW ITCH
W ITHOUT INDUCER ON
PRESSURE SW ITCH OPEN
IGNITION F AILURE
NORMAL OPERATION
NO POW ER OR
INTERNAL CO NTROL
FAULT
STATUS
CHECK
CHECK FOR SHO RTS IN
FLAME SENSOR W IRING
-
NORMAL FLAME PRESENT
DIAGNOSTIC
LED - AMBER
-
GAS PRESSURE
FLAME SENSOR
GAS VALVE
GAS FLOW
CHECK GAS VA LVE
ON
OFF
1 FLASH
2 FLASHES
FALSE FLAME DETECTED
LOW FLAME SIGNAL
NO FLAME PRESENT
STATUS
CHECK
PSW /LOC O PEN
9 FLASHES
CHECK JUM PER BETW EEN 1
AND 4 ON 6- CIRCUIT
CON NECTOR
IDT/ODT OPEN
8 FLASHES
CHECK AUXILIARY LIMIT SW .
CHECK MAIN LIMIT SW ITCH
LIMIT OPEN 5 TIMES IN SAME
CALL FOR HE AT
DIAGNOSTIC
LED - RED
7 FLASHES
STATUS
CHECK
CHECK OPTIONAL
REFRIGERAN T SW ITCHES
CHECK R EFRIGERANT
SW ITCHES FOR LO SS OF
CHARGE OR HIGH HEAD
PRESSURE