54
SERVICING
Service Problem
No Heat
Unsatisfactory
Heat
POSSIBLE CAUSE
DOTS IN ANALYSIS
GUIDE INDICATE
"POSSIBLE CAUSE"
SYM
PT
O
M
Sy
s
te
m
Wi
ll
N
o
t St
a
rt
B
u
rn
e
r W
on'
t I
g
ni
te
B
u
rn
er
I
g
n
it
e
s
-L
o
ck
s O
u
t
B
u
rn
er
S
h
u
ts
O
ff
p
rio
r
to
T
'S
ta
t b
e
in
g
S
a
ti
s
fied
S
h
o
rt
C
y
cl
es
Lo
ng C
y
c
le
s
S
o
ot
a
n
d
/
o
r Fu
m
e
s
Too M
u
c
h
H
e
a
t
N
o
t E
n
oug
h H
e
a
t
Test Method
Remedy
S
e
e
S
e
rv
ic
e
P
roc
e
dur
e
R
e
fe
re
nc
e
Pow er Failure
•
Test Voltage
S-1
Blow n Fuse
•
Test Voltage
S-4
Loose Connection
•
Check Wiring
S-2
Shorted or Broken Wires
•
Check Wiring
S-3A
No Low Voltage
•
Check Transformer
S-4
Faulty Thermostat
•
• •
• •
Check Thermostat
S-3A
Faulty Transformer
•
Check Transformer
S-4
Poor or High Resistance Ground
•
Measure Ground Resistance
S-17B
Improper Heat Anticipator Setting
• •
• •
Adjust Heat Anticipator Setting
S-3B
Improper Thermostat Location
• •
• •
Relocate Thermostat
S-316
Faulty Limit or Roll Out Sw itch
•
•
Test Control
S-300 / S-302
Faulty Flame Sensor
•
Test Flame Sensor
S-314
Faulty Ignition Control
• • •
Test Control
S-313
Gas Valve or Gas Supply Shut Off
•
Turn Valves to On Position
S-317
Faulty Induced Draft Blow er
•
•
Test Induced Draft Motor
S-303
Faulty Blow er Motor (PSC)
•
•
Test Blow er Motor (PSC)
S-16A,B,C
Broken or Shorted Ignitor
•
Test Ignitor
S-308
Dirty Flame Sensor, Low UA
•
Clean Flame Sensor
S-314
Stuck Gas Valve
•
• •
Replace Gas Valve
S-304
Faulty Gas Valve
•
•
•
Replace Gas Valve
S-304
Open Auxiliary Limit
•
•
Reset Control
S-301
Improper Air Flow or Distribution
•
•
Check Duct Static
S-200
Cycling on Limit
• •
•
Check Controls & Temperature Rise
S-201 / S-300
Delayed Ignition
•
Test for Delayed Ignition
S-312
Flashback
•
Test for Flashback
S-309 / S-311
Orifice Size
• • •
Check Orifices
S-306 / S-311
Gas Pressure
•
• • •
Check Gas Pressure
S-307
Cracked Heat Exchanger
•
Check Burner Flames
S-305
Furnace Undersized
•
•
Replace w ith Proper Size Furnace
S-318
Furnace Oversized
•
Replace w ith Proper Size Furnace
S-318
Faulty Pressure Sw itch
• • •
Test Pressure Sw itch
S-310
Blocked or Restricted Flue
•
Check Flue/Draw dow n Pressure
S-310
Open Roll Out Sw itch
• •
Test Flame Roll Out Control
S-302
Bouncing On Pressure Sw itch
•
Test Negative Pressure
S-310