GENERAL INFORMATION

WARNING

To prevent property damage, personal injury 

or death, due to fire, explosions, smoke, 

soot, condensation, electric shock or carbon 

monoxide, this unit must be properly installed, 

repaired, operated, and maintained. 

This unit is approved for outdoor installation ONLY

Not accessible to the general public. 

Rated performance 

is achieved after 20 hours of operation. Rated performance 

is delivered at the specified airflow. See outdoor unit 

specification sheet for split system models or product 

specification sheet for packaged and light commercial 

models. Specification sheets can be found at 

www.

daikinac.com for Daikin brand products. Within the website, 

please select the residential or commercial products menu 

and then select the submenu for the type of product to be 

installed, such as air conditioners or heat pumps, to access 

a list of product pages that each contain links to that 

model’s specification sheet.

To assure that your unit operates safely and efficiently, it 

must be installed, operated, and maintained in accordance 

with these installation and operating instructions, and all 

local building codes and ordinances, or in their absence, 

with the latest edition of the National Fuel Gas Code 

NFPA54/ANSI Z223.1 and  National Standard of Canada 

CAN/CSA B149 Installation Codes. 

EPA Regulations

Important: The United States Environmental 

Protection Agency (EPA) has issued various 

regulations regarding the introduction and 

disposal of refrigerants in this unit. Failure 

to follow these regulations may harm the 

environment and can lead to the imposition of 

substantial fines. Because regulations may vary 

due to passage of new laws, we suggest a certified 

technician perform any work done on this unit. 

Should you have any questions please contact the 

local office of the EPA.

National Codes

This product is designed and manufactured to permit  

installation in accordance with National Codes. It is the 

installer’s responsibility to install the product in accordance 

with National Codes and/or prevailing local codes and 

regulations.

The heating and cooling capacities of the unit should be 

greater than or equal to the design heating and cooling 

loads of the area to be conditioned. The loads should be 

calculated by an approved method or in accordance with 

ASHRAE Guide or Manual J - Load Calculations published 

by the Air Conditioning Contractors of America.

AVERTISSEMENT

RISQUE D’INTOXICATION AU MONOXYDE DE  

CARBONE

Si les étapes décrites ci-dessous ne sont pas suivies pour 

chacun des appareils raccordés au système de ventilation 

au moment de sa mise en marche, cela peut entraîner une 

intoxication au monoxyde de carbone ou la mort. Les étapes 

suivantes doivent être suivies pour chacun des appareils 

raccordés au système de ventilation au moment de sa mise 

en marche, alors que tous les autres appareils raccordés au 

système de ventilation ne sont pas en marche :

1) Sceller toutes les ouvertures inutilisées du système de  

ventilation.

2) Inspecter le système de ventilation afin de vérifier si la taille 

et l’inclinaison par rapport à l’horizontale sont conformes aux 

exigences du National Fuel Gas Code, ANSI Z223.1/NFPA 54 ou 

du Code d’installation du gaz naturel et du propane, CSA B149.1 

et à ces instructions. Vérifier qu’il n’y a pas d’obstruction ou 

de restriction, de fuite, de corrosion et d’autres problèmes qui 

pourraient entraîner une situation dangereuse.

3) Si possible, fermer toutes les portes et fenêtres du bâtiment 

ainsi que toutes les portes séparant l’endroit où se trouvent 

les appareils raccordés au système de ventilation et les autres 

zones du bâtiment.

4) Fermer le registre des foyers.

5) Mettre les sécheuses en marche ainsi que tous les autres 

appareils qui ne sont pas raccordés au système de ventilation. 

Mettre en marche tous les ventilateurs de tirage, comme celui 

des hottes de cuisine et des salles de bains, et les régler à la 

puissance maximale. Ne pas mettre en marche les ventilateurs 

d’été.

6) Suivre les instructions d’allumage. Mettre en marche l’appareil 

soumis à l’inspection. Régler le thermostat de manière à ce que 

l’appareil fonctionne en continu.

7) Vérifier la présence de fuite au niveau de l’ouverture du 

coupe-tirage des appareils qui en sont dotés après 5 minutes 

de fonctionnement du brûleur principal. Utiliser la flamme d’une 

allumette ou d’une bougie.

8) Si un problème de ventilation est observé pendant l’un des 

essais décrits ci-dessus, des correctifs doivent être apportés 

au système de ventilation conformément au National Fuel Gas 

Code, ANSI Z223.1/NFPA 54 et (ou) au Code d’installation du gaz 

naturel et du propane, CSA B149.1.

9) Une fois qu’il a été déterminé que chaque appareil raccordé 

au système de ventilation fonctionne correctement au moyen 

des essais décrits ci-dessus, les portes, les fenêtres, les 

ventilateurs, les registres de foyer et tous les autres appareils de 

combustion alimentés au gaz doivent être remis dans leur état 

initial.  

Summary of Contents for DFG Series

Page 1: ...DURES IF YOU SERVICE THIS UNIT YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT IN ADDITION IN JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT SPEC...

Page 2: ...ure reference WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life do not store or use gasoli...

Page 3: ...or the gas supply fail to shut off turn off the manual gas shutoff valve external to the furnace before turning off the electrical supply CAUTION Sheet metal parts screws clips and similar items inhe...

Page 4: ...xyde de carbone Si vous devez faire fonctionner ces appareils dans un endroit clos assures vous qu il y ait une ventilation directe provenant de l exterier Cette ventilation est n cessaire pour viter...

Page 5: ...onditioning Contractors of America AVERTISSEMENT RISQUE D INTOXICATION AU MONOXYDE DE CARBONE Si les tapes d crites ci dessous ne sont pas suivies pour chacun des appareils raccord s au syst me de ven...

Page 6: ...onsiderations are taken into account before starting installation Assemble all tools hardware and supplies needed to complete the installation Some items may need to be purchased locally WARNING To pr...

Page 7: ...Precautions Do not stand or walk on the unit Do not drill holes anywhere in panels or in the base frame of the unit except where indicated Unit access panels provide structural support Do not remove a...

Page 8: ...flue extension kit needs be to installed to prevent flue gas recirculation See table below for the kit selection Model size Kit part number 7 5 8 5 10 T HEFLUE090120 12 5 T HEFLUE150 Flue Extension K...

Page 9: ...mage Removal is accomplished by extracting the sheet metal retainers and pulling the struts through the base of the unit Refer to rigging label on the unit Your unit may be equipped with a steel shipp...

Page 10: ...center 29 29 27 30 DFG Weights lbs Data The numbers may slightly vary depending on installed options CAUTION To prevent severe damage to the bottom of the unit do not fork lift unit after wood struts...

Page 11: ...e is 208V lead on primary of transformer s must be moved from the 230V to the 208V tap Refer to wiring diagram on unit for details Main power wiring should be sized for the minimum circuit ampacity sh...

Page 12: ...These outlets can also be factory installed Units installed on Roof Tops Main power and low voltage wiring may enter the unit through the condenser end of unit or through the roof curb Install conduit...

Page 13: ...the gas supplier IMPORTANT NOTE This unit is factory set to operate on natural gas at the altitudes shown on the rating plate WARNING To avoid property damage personal injury or death when either usi...

Page 14: ...gid metallic pipe and fittings Semirigid metallic tubing and metallic fittings Aluminum alloy tubing must not be used in exterior locations Listed gas appliance connectors used in accordance with the...

Page 15: ...lators and between second stage regulator and the appliance Pipe size required will depend on length of pipe run and total load of all appliances Tanks and Piping Complete information regarding tank s...

Page 16: ...ide of the manifold for checking manifold pressure WARNING This unit and its individual shutoff valve must be DISCONNECTED from the gas supply system during any pressure testing of that system at test...

Page 17: ...following steps should be completed in the building WARNING MOVING MACHINERY HAZARD To prevent possible personal injury or death disconnect power to the unit and padlock in the OFF position before ser...

Page 18: ...e red wire coming from the induced draft motor It is important to your safety that the unit has been properly grounded during installation Check ground lug connection in main control box for tightness...

Page 19: ...T4 or T5 to change blower speed during cooling stage 2 operation Do not move wires YL and PU to the same taps Move BROWN BR wire from TB1 T8 to T9 or T10 to change blower speed during heating stage 2...

Page 20: ...k for gas leaks Since the unit is subject to considerable jarring during shipment it is extremely important that all gas connections and joints be tested for tightness Gas piping downstream from the u...

Page 21: ...gas supply to all other appliances except the unit manifold pressure to obtain rating it is mandatory that the input be adjusted at the installation site All installations should be made as outlined...

Page 22: ...rom outlet pressure boss 2 Turn outlet pressure tap screw in to seal pressure port clockwise 7 in lb minimum 3 Turn on electrical power and gas supply to the system 4 Turn on system power and energize...

Page 23: ...ed MUST be set to give the correct air temperature rise through the unit as marked on the rating plate NORMAL SEQUENCE OF OPERATION Heating NOTE On units with the DDC controls option installed refer t...

Page 24: ...inals R and G and across R and Y on TB1 terminal block Close the disconnect switch The following operational sequence should be observed 1 Current through primary winding of transformer TRANS1 energiz...

Page 25: ...f 15 minutes between adjustments to allow time for the TXV and pressures to stabilize 8 With all safety devices closed the system will continue cooling operation until the thermostat is satisfied 9 Di...

Page 26: ...per heat remove charge and to decrease super heat add charge After superheat is adjusted it is recommended to check unit subcooling at the condenser coil liquid line See Design Superheat and Subcoolin...

Page 27: ...created by the fuel or combustion air supply can be removed by carefully cleaning the flame sensor with steel wool NOTE After cleaning the microamp signal should be stable and in the range of 4 6 micr...

Page 28: ...ent Contact a qualified servicer at once if an abnormal flame should develop At least once a year prior to or during the heating season make a visual check of the burner flames NOTE This will involve...

Page 29: ...s an open pressure switch during the pre purge cycle the induced draft blower only will be energized If the pressure switch opens after ignition has begun the gas valve is deenergized the circulator b...

Page 30: ...3 9 0 42 0 4 2132 0 601 7 314 8 0 48 0 4 2137 3 590 3 311 2 0 47 0 6 1957 7 663 6 338 8 0 53 0 6 1956 9 652 6 345 5 0 52 0 8 1803 0 707 6 363 5 0 57 0 8 1713 7 726 5 379 4 0 58 0 2 3291 4 683 9 652 8...

Page 31: ...0 6 1918 8 659 8 327 2 0 51 3 05 4 08 0 6 1916 9 648 9 335 2 0 50 3 05 4 08 0 8 1761 7 704 1 351 6 0 55 3 05 4 08 0 8 1668 1 724 0 368 8 0 56 3 05 4 08 1 1557 5 765 2 383 3 0 59 3 05 4 08 1 1 2 1 2 1...

Page 32: ...6 2365 8 704 4 469 2 0 75 0 6 2369 3 693 0 463 8 0 74 0 8 2235 2 745 3 498 5 0 79 0 8 2183 6 754 8 500 0 0 80 1 2065 5 800 4 536 8 0 85 1 1989 9 815 8 531 6 0 87 1 2 1882 3 851 2 558 9 0 90 1 2 1834...

Page 33: ...8 393 3 0 63 0 2 2660 0 570 3 371 8 0 59 0 4 2425 6 646 0 416 5 0 67 0 4 2497 6 626 2 405 8 0 65 0 6 2215 3 714 1 453 4 0 74 0 6 2339 6 682 6 438 6 0 71 0 8 2027 6 772 9 492 1 0 80 0 8 2140 5 748 8 47...

Page 34: ...2 482 2 0 79 0 8 2181 7 784 2 538 1 0 89 0 8 2300 8 757 9 523 1 0 86 1 2029 0 831 2 563 4 0 94 1 2115 9 812 8 560 5 0 92 1 2 1871 1 875 6 593 9 0 99 1 2 1967 8 865 5 589 0 0 98 1 4 1673 6 932 3 629 2...

Page 35: ...0 0 94 0 6 2727 3 765 2 627 1 1 05 0 6 2845 8 732 7 609 9 1 00 0 8 2577 4 815 3 672 2 1 12 0 8 2710 9 783 6 653 8 1 07 1 2443 1 859 6 700 6 1 18 1 2554 1 833 6 696 4 1 14 1 2 2304 9 899 9 734 3 1 23 1...

Page 36: ...856 8 1260 7 0 81 0 8 2931 1 812 1 1196 2 0 77 0 2 3735 1 821 6 1564 9 1 63 0 2 3882 5 754 3 1450 6 1 50 0 4 3659 0 851 3 1631 5 1 69 0 4 3780 8 790 7 1520 1 1 57 0 6 3568 1 892 2 1697 1 1 77 0 6 367...

Page 37: ...9 7 1265 7 1 25 0 6 3263 5 850 0 1419 0 1 42 0 6 3362 5 796 6 1336 4 1 33 0 8 3132 0 889 5 1483 0 1 49 0 8 3239 2 838 6 1403 3 1 40 1 3008 1 929 0 1539 5 1 55 1 3123 1 883 0 1467 6 1 48 1 2 2838 5 971...

Page 38: ...39 0 2 3689 1 724 8 1282 9 1 28 0 4 3467 3 819 9 1446 3 1 45 0 4 3583 4 763 6 1348 6 1 35 0 6 3371 2 864 3 1509 7 1 52 0 6 3473 7 809 0 1421 6 1 43 0 8 3242 3 902 4 1575 1 1 59 0 8 3352 1 849 5 1489 2...

Page 39: ...590 3 311 2 0 47 0 6 1957 0 663 4 337 9 0 53 0 6 1956 2 652 6 345 5 0 52 0 8 1802 4 707 5 362 6 0 57 0 8 1713 2 726 5 379 4 0 58 0 2 3652 3 738 1 828 1 1 37 0 2 3664 9 724 5 794 9 1 35 0 4 3518 0 779...

Page 40: ...8 9 335 2 0 50 0 8 1761 2 704 1 351 0 0 54 0 8 1 1 1 2 1 2 1 4 1 4 0 2 2579 9 578 8 369 8 0 56 0 2 2579 9 567 7 369 8 0 55 0 4 2414 9 636 5 404 8 0 62 0 4 2424 1 625 0 393 6 0 61 0 6 2256 1 693 0 430...

Page 41: ...7 0 6 2363 6 703 8 465 8 0 73 0 6 2369 3 693 0 463 8 0 72 0 8 2233 8 744 6 494 9 0 78 0 8 2183 6 754 8 500 0 0 79 1 2064 2 799 8 533 5 0 84 1 1989 9 815 8 531 6 0 85 1 2 1881 0 850 5 555 5 0 89 1 2 18...

Page 42: ...0 4 2497 6 626 2 405 8 0 65 0 6 2215 3 714 1 453 4 0 74 0 6 2339 6 682 6 438 6 0 71 0 8 2027 6 772 9 492 1 0 80 0 8 2140 5 748 8 478 2 0 78 0 2 3617 6 772 3 875 2 1 51 0 2 3761 2 730 0 838 4 1 43 0 4...

Page 43: ...0 87 0 8 2300 8 757 9 523 1 0 84 1 2029 0 831 2 563 4 0 93 1 2115 9 812 8 560 5 0 91 1 2 1871 1 875 6 593 9 0 98 1 2 1967 8 865 5 589 0 0 96 1 4 0 00 1 4 1729 3 958 1 641 4 1 07 0 2 3023 2 680 4 575...

Page 44: ...1 00 0 8 2577 4 815 3 672 2 1 12 0 8 2710 9 783 6 653 8 1 07 1 2443 1 859 6 700 6 1 18 1 2554 1 833 6 696 4 1 14 1 2 2304 9 899 9 734 3 1 23 1 2 2414 1 881 8 728 9 1 21 1 4 2107 5 954 7 769 8 1 31 1...

Page 45: ...0 8 2931 1 812 1 1196 2 0 77 0 2 3735 1 821 6 1564 9 1 63 0 2 3882 5 754 3 1450 6 1 50 0 4 3659 0 851 3 1631 5 1 69 0 4 3780 8 790 7 1520 1 1 57 0 6 3568 1 892 2 1697 1 1 77 0 6 3676 0 833 8 1597 8 1...

Page 46: ...9 7 1265 7 1 25 0 6 3263 5 850 0 1419 0 1 42 0 6 3362 5 796 6 1336 4 1 33 0 8 3132 0 889 5 1483 0 1 49 0 8 3239 2 838 6 1403 3 1 40 1 3008 1 929 0 1539 5 1 55 1 3123 1 883 0 1467 6 1 48 1 2 2838 5 971...

Page 47: ...1 724 8 1282 9 1 28 0 4 3467 3 819 9 1446 3 1 45 0 4 3583 4 763 6 1348 6 1 35 0 6 3371 2 864 3 1509 7 1 52 0 6 3473 7 809 0 1421 6 1 43 0 8 3242 3 902 4 1575 1 1 59 0 8 3352 1 849 5 1489 2 1 50 1 3122...

Page 48: ...5 750 9 1692 9 1 85 0 4 4117 5 827 9 1195 4 2 04 0 4 4266 5 789 2 1779 3 1 94 0 6 4003 0 867 5 1244 8 2 13 0 6 4164 7 827 4 1860 0 2 04 0 8 3861 3 910 4 1295 3 2 24 0 8 4033 6 867 9 1944 5 2 13 0 2 4...

Page 49: ...2199 8 789 1 848 9 0 82 0 8 2273 4 744 7 813 8 0 77 1 2017 1 848 1 912 6 0 88 1 2165 5 803 9 874 3 0 84 1 2 1 2 1 4 1 4 0 2 3145 9 675 7 963 3 0 89 0 2 3276 4 619 8 888 2 0 82 0 4 2995 9 729 2 1026 0...

Page 50: ...2 687 4 753 4 0 71 0 8 2199 8 789 1 848 9 0 82 0 8 2273 4 744 7 813 8 0 77 1 2017 1 848 1 912 6 0 88 1 2165 5 803 9 874 3 0 84 1 2 1 2 1 4 1 4 1 6 1 6 1 8 1 8 0 2 3145 9 675 7 963 3 0 89 0 2 3276 4 61...

Page 51: ...0 1011 2 1 00 0 4 3311 8 658 6 867 9 0 92 0 6 3071 9 763 4 1065 9 1 06 0 6 3193 2 709 4 927 5 0 99 0 8 2837 2 825 0 1130 8 1 15 0 8 2995 6 783 9 1011 8 1 09 0 2 4183 5 802 7 1644 1 1 74 0 2 4358 6 70...

Page 52: ...161 0 1 18 1 2754 6 823 3 1032 1 1 11 1 2 2311 4 929 5 1225 9 1 25 1 2 2426 7 914 8 1144 7 1 23 1 4 2121 0 974 2 1281 8 1 31 1 4 2289 3 958 1 1197 2 1 29 0 2 3756 2 741 8 1270 8 1 31 0 2 3910 4 656 9...

Page 53: ...5 827 5 1363 4 1 33 1 3193 0 936 2 1649 5 1 50 1 3048 7 883 5 1445 3 1 42 1 2 3049 6 972 9 1714 7 1 56 1 2 2846 6 935 1 1524 8 1 50 1 4 2860 1 1020 1 1784 8 1 64 1 4 2633 4 990 8 1612 1 1 59 1 6 2698...

Page 54: ...7 6 1 36 0 4 3535 7 826 7 941 0 1 61 0 4 3782 2 736 8 861 3 1 44 0 6 3420 2 869 0 990 6 1 69 0 6 3653 8 786 5 917 1 1 53 0 8 3242 3 920 6 1047 3 1 79 0 8 3439 3 853 8 972 7 1 66 0 2 4193 3 895 3 1393...

Page 55: ...07 3 1 94 0 8 3811 3 887 4 1230 8 1 81 1 3419 1 997 1 1371 1 2 03 1 3622 0 941 8 1287 0 1 92 1 2 3235 5 1046 4 1432 8 2 13 1 2 3511 9 971 8 1329 8 1 98 1 4 3088 5 1082 6 1478 9 2 21 1 4 3277 3 1034 7...

Page 56: ...1 59 0 6 3600 6 816 9 1007 9 1 48 0 8 3259 7 919 1 1122 9 1 66 0 8 3465 0 861 2 1060 8 1 56 1 3091 1 964 7 1184 0 1 74 1 3266 0 917 3 1111 7 1 66 1 2 2893 8 1015 7 1241 8 1 84 1 2 3143 8 952 7 1155 2...

Page 57: ...1 6 249 8 0 36 0 4 1967 2 566 3 239 8 0 34 0 6 1556 2 658 1 271 5 0 40 0 6 1645 3 656 4 272 7 0 40 0 8 0 8 1464 3 707 0 272 2 0 43 0 2 4637 0 860 2 1378 5 2 30 0 2 4766 7 802 3 1302 9 2 14 0 4 4541 8...

Page 58: ...3026 8 670 8 579 3 0 83 0 6 2764 6 762 2 649 5 0 95 0 6 2763 3 744 9 629 9 0 93 0 8 2611 1 805 7 684 9 1 00 0 8 2614 1 795 5 676 6 0 99 1 1 1 2 1 2 1 4 1 4 0 2 3751 2 721 7 824 1 1 18 0 2 3764 8 687 2...

Page 59: ...6 1 8 1 8 0 2 2652 3 564 3 348 5 0 51 0 2 2598 1 536 4 330 1 0 49 0 4 2393 4 641 4 387 9 0 58 0 4 2431 1 608 7 372 1 0 55 0 6 2136 2 710 3 430 3 0 65 0 6 2099 4 700 7 427 0 0 64 0 8 1972 3 756 4 463...

Page 60: ...63 0 0 71 0 4 2742 7 723 8 560 2 0 87 0 4 3039 3 650 6 513 5 0 79 0 6 2538 2 774 7 594 8 0 93 0 6 2843 8 717 2 557 6 0 87 0 8 0 8 2703 4 768 9 591 8 0 93 0 2 4410 4 928 5 1478 6 2 48 0 2 4801 9 804 8...

Page 61: ...7 1 04 0 4 3423 6 777 8 819 9 1 21 0 4 3584 6 722 3 771 6 1 12 0 6 3248 9 825 1 869 8 1 28 0 6 3426 4 775 7 820 2 1 20 0 8 3093 3 864 8 904 3 1 34 0 8 3271 0 829 3 873 0 1 29 1 2897 7 910 5 954 8 1 41...

Page 62: ...713 8 738 5 1 07 0 6 3165 0 816 7 832 3 1 23 0 6 3340 7 768 8 786 7 1 15 0 8 3008 5 856 6 866 4 1 29 0 8 3180 8 823 3 838 8 1 24 1 2811 8 902 5 915 4 1 35 1 3037 8 867 7 879 0 1 30 1 2 2651 5 943 6 9...

Page 63: ...00 0 2 4411 7 748 1 1035 5 1 70 0 4 3902 9 908 4 1243 1 2 07 0 4 4325 5 789 8 1085 4 1 80 0 6 3756 1 950 4 1289 0 2 16 0 6 4254 7 827 8 1139 0 1 88 0 8 3576 2 993 1 1335 2 2 26 0 8 4156 7 872 3 1195...

Page 64: ...4 3995 0 914 7 1294 7 1 91 0 4 4323 0 805 2 1147 6 1 68 0 6 3854 2 951 1 1335 4 1 99 0 6 4199 4 845 9 1195 2 1 77 0 8 3725 9 986 9 1384 0 2 06 0 8 4096 6 888 3 1256 7 1 86 1 3569 8 1025 3 1423 6 2 14...

Page 65: ...2 932 6 1379 0 2 04 0 4 4450 7 820 2 1223 2 1 80 0 6 3980 9 967 8 1420 5 2 12 0 6 4337 6 858 0 1271 1 1 88 0 8 3854 1 1002 8 1470 2 2 20 0 8 4237 5 899 6 1334 2 1 97 1 3700 8 1039 7 1510 5 2 28 1 4089...

Page 66: ...3 5 1 7 20 8 25 5 2 0 33 0 67 Direct Drive High Static 3 5 DFG0907W 575 3 60 2 4 4 33 4 DFG0907L 575 3 60 2 4 4 33 2 0 33 0 67 Direct Drive Medium Static 2 4 4 2 0 33 0 67 Direct Drive Standard Static...

Page 67: ...25 3 5 1 7 24 6 30 5 DFG1027W 575 3 60 2 6 41 2 0 33 0 67 Direct Drive High Static 3 5 5 2 0 33 0 67 Direct Drive Medium Static 3 5 DFG1027L 575 3 60 2 6 41 7 2 DFG1027D 575 3 60 2 6 41 2 0 33 0 67 D...

Page 68: ...5 1 7 26 4 30 7 2 2 0 33 0 67 Direct Drive High Static 5 DFG1207W 575 3 60 2 5 8 38 9 5 DFG1207L 575 3 60 2 5 8 38 9 2 0 33 0 67 Direct Drive Medium Static 5 7 2 2 0 33 0 67 Direct Drive Standard Stat...

Page 69: ...1 7 27 1 30 3 5 1 7 30 6 35 7 2 DFG1507W 575 3 60 2 7 4 50 2 0 5 1 Direct Drive High Static 5 7 2 2 0 5 1 Direct Drive Medium Static 5 DFG1507L 575 3 60 2 7 4 50 10 6 DFG1507D 575 3 60 2 7 4 50 2 0 5...

Page 70: ...cal Discharge Top View of Unit NOTE For horizontal discharge remove supply and return duct cover panels from the end of the unit Save all washered screws According to the model size remove 6 or 8 fact...

Page 71: ...OMMENDED MIN MAX AIRFLOW RANGE UNIT HIGH FIRE RATE BTU HR HEATING MINIMUM SCFM COOLING MINIMUM SCFM MAXIMUM SCFM DFG090 210 000 2250 2360 3690 DFG102 210 000 2550 2680 4230 DFG120 210 000 3000 3150 48...

Page 72: ...Y1 Y2 O DH T1 T2 T3 T4 T5 TB1 PLF1 BM BL GY GR YL PU WH BR BL BL BR WH PU YL GY YL WH GR RD RD RD BL 9 1 2 4 5 3 6 7 8 ES PLF PLM 4 1 2 3 4 1 2 3 RD PK RD RD PU PU 8 GR BL BL BL WH 7 9 1 2 7 4 3 6 5...

Page 73: ...73...

Page 74: ...74...

Page 75: ...75 PAGE LEFT INTENTIONALLY BLANK...

Page 76: ...kincomfort com PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty registering your product is a relatively short process and ent...

Reviews: