background image

9

English

(Example)
When the data from 25 Oct. 2000 to 24 Nov. 2000 are 
totalled, the results are indicated as 
“20001025_20001124. CSV”.  If the file of the same name 
already exists, it overwrites.

2.

File format :

(Example)
Start Date, Nb of Days, A/C Type, Undistributed Power 
Amount,Period Type 
20050101,31,0,0,200501

A/C Unit No,In/Unit Name,HP Code,Daytime Used 
Pwr,Nighttime Used Pwr,Daytime Idle Pwr,Nighttime Idle 
Pwr,Gas Amount
0,“’1:1-00”,38,2459,0,0,0,0
1,“’1:1-01”,38,2718,0,0,0,0
2,“’1:1-02”,38,3105,0,0,0,0
3,“’1:1-03”,38,3494,0,0,0,0
4,“’1:1-04”,38,4141,0,0,0,0

60,“’1:4-12”,70,489,0,0,0,0
61,“’1:4-13”,8c,779,0,0,0,0
62,“’1:4-14”,2d,779,0,0,0,0
63,“’1:4-15”,47,1115,0,0,0,0

[Cautions]

Meaning of each data
Start Date 

: The starting day of sum

Nb of Days 

: Number of days of sum 

A/C Type 

: 0 fixed

Undistributed Power Amount 

: 0 fixed

Period Type 

: Period designation system (0 : Period 

designation system, Date : Month desig-
nation system)

A/C Unit No 

: Number of indoor unit (0 ~ 63.)

In/Unit Name 

: Name of indoor unit

HP Code 

: Horsepower of indoor unit

Daytime Used Pwr  : Power amount used
Nighttime Used Pwr  : Not used
Daytime Idle Pwr 

: Electric power amount at stoppage (The 

amount is displayed, only when power 
proportional distribution calculation is 
not carried out at stoppage.)

Nighttime Idle Pwr 

: Not used

Gas Amount 

: Not used

3. Detailed information file

1.

File name : HOURLY.CSV

If the detailed information already exists, it will 
overwrite.
Therefore, it is necessary to backup the data 
to a PC at every data output.

The data of the period designated by the power propor-
tional distribution report (from 01:00 of the day the tabula-
tion started to 0:00 of the next day the tabulation ended) 
are output.  Regardless of whether the registration exists 
or not in the commissioning tool, the results of 64 (or 128) 
units of air conditioners are output.

2.

File format:

(Example)
PPD Hourly Data (Wh)
Note:,Date and Time mean the calculation time of PPD.
,The value of 3:00 is a result between the calculation time 
just before 3:00 and 3:00.
Date,Time,’1:1-00,’1:1-01,’1:1-02,’1:1-03, --- ,’1:4-15,
2006.9.10 1:00
50,21,15,21,20,21,30, --- 45,53,18,41,15, --- 15
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
45,20,31,20,21,21,30, --- 15,14,13,23,25, --- 18
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
2006.9.10 2:00
24,31,15,14,13,10,10, --- 45,32,14,19,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
31,24,25,15,16,17,32, --- 15,10,21,15,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
2006.9.10 3:00
50,21,15,21,20,21,30, --- 45,53,18,41,15, --- 15
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
45,20,31,20,21,21,30, --- 15,14,13,23,25, --- 18
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
2006.9.10 4:00
24,31,15,14,13,10,10, --- 45,32,14,19,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
31,24,25,15,16,17,32, --- 15,10,21,15,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
2006.9.10 5:00
50,21,15,21,20,21,30, --- 45,32,14,19,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
45,20,31,20,21,21,30, --- 15,10,21,15,18, --- 16
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
2006.10.10 0:00
45,32,14,19,18,21,16, --- 24,31,15,14,13, --- 10
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0
15,10,21,15,18,21,16, --- 31,24,25,15,16, --- 15
  0,  0,  0,  0,  0,  0,  0, ---   0,  0,  0,  0,  0, ---   0

[Cautions]

View of data

Indoor Unit No. 1-00
The data shown covers a 
period from 1:00 to 3:00 on 
August 1, 2006.
Used Power         10kw
Not Used
Idling Power          5kw
Not Used

01_EM06A043_EN.fm  Page 9  Monday, October 16, 2006  11:25 AM

Summary of Contents for DCS002A71

Page 1: ...before use When you have read this manual be sure to store it in a place where the operator can conve niently refer to at anytime In case of personnel change be sure to give the manual to the new oper...

Page 2: ...complete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer for improvement repair and mainte nance Incomplete improvement repair and maintenance...

Page 3: ...air conditioner per indoor unit Main Functions Power proportional distribution results data can be saved for 12 months max 12 months and 30 days Per intelligent Touch Controller power proportional di...

Page 4: ...Power proportional distribution main menu Exclusion Periods Normal Type Special Calculation Days Normal Type Power Proportional Distribution Report See page 4 Case to time limit set up Case to design...

Page 5: ...hen to end setup press OK button 1 How to set Begin Time Press Begin button of the week day you want to set and set the begin time in exclusion periods where power proportional distribution calculatio...

Page 6: ...een Display Procedures Press Special Calculation Days Normal Type 3 When to end setup press OK button 2 Select the day you want to set When the day portion is pressed a is displayed When the day porti...

Page 7: ...ebruary the power proportional distribution result of 1 to 31 January is summed up Display of Power Proportional Distribution Report After selecting either Time Limit Setup or Month when Exe cute butt...

Page 8: ...into the insertion mouth on the left hand side of the intelligent Touch Controller Check that the Power Proportional Distribution Card is seated in the right direction as shown below Display of Power...

Page 9: ...en Power Proportional Distribution Report is saved a zone information file an electric power information file and detailed information file are created 1 Zone information file This contains zone name...

Page 10: ...ta output The data of the period designated by the power propor tional distribution report from 01 00 of the day the tabula tion started to 0 00 of the next day the tabulation ended are output Regardl...

Page 11: ...ower Propor tional Distribution Report The intelligent Touch Control ler does not have printing function To print out Power Proportional Distribution Report print out the data of CSV format saved in P...

Page 12: ...phone number Transfer Transfer requires professional technique Be sure to contact the supplier you purchased the product from or service sta tion The customer will be charged for the expense required...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...0609 HT EM06A043 00_CV_EM06A043 fm Page 2 Tuesday September 12 2006 1 27 PM...

Reviews: