D2C20ND0 D2C24ND035A5AA
Wall-mounted condensing boiler
3P469438-10H – 2018.05

#

Description

Unit Default Range

U06

Set value for the room
thermostat at reduced mode

°C

18

10~30

U07

Set value for the flow
temperature at day mode

°C

50

30~80

U08

Set value for the flow
temperature at reduced mode

°C

35

30~80

U09

Domestic hot water comfort
mode user record dependency

1

1, 2 or

24

U10

Room temperature setpoint
used by Daikin room thermostat
during night

°C

18

10~30

t00

(a)

Year

1~99

t01

(a)

Mounth

1~12

t02

(a)

Day

1~31

t03

(a)

Hour

0~23

t04

(a)

Minute

0~59

(a)

Applicable if energy metering is enabled.

User settings menu: Parameters (detailed)

#

Description

U00

When using outdoor sensor, above this parameter
value of outside temperature, the boiler senses the
season as summer and does not activate central
heating although there is demand. Summer-winter
switching has a hysteresis of ±1ºC.

i.e: When this parameter is adjusted to 20ºC, the boiler
switches to summer mode at 21ºC and switches back
to winter mode at 19ºC.

U01

This value is used when only outside sensor is
connected to the boiler (No Opentherm room
thermostat connection). The parameter heating slope is
important to adapt the weather compensation to the
individual heating system, the building and the thermal
insulation. 

The heating slope can be adjusted from 0

to 40. The heating slope needs to be increased to
increase the boiler central heating set temperature.
Colder regions require a higher heating slope value.

Note: 

To activate weather compensation, the heating

slope value must be higher than "5".

U02

Enabling / disabling central heating ECO mode.

1 = enabled, 0 = disabled

U03

Enabling / disabling domestic hot water comfort mode.

1 = enabled, 0 = disabled

U04

Domestic hot water set value (same function that can
be done via the right dial when domestic hot water
mode is enabled).

U05

When On-Off room thermostat and outdoor sensor are
both connected, this parameter value is the virtual room
temperature setpoint when there is a heat demand.

U06

When On-Off room thermostat and outdoor sensor are
both connected, this parameter value is the virtual room
temperature setpoint when there is no heat demand.

Note: 

For this parameter value to be active, reducing

mode has to be enabled by your service agent,
otherwise central heating mode will not be activated
when there is no heat demand.

U07

When On-Off room thermostat is connected and
outdoor sensor is not connected, this parameter value
is the central heating water temperature setpoint when
there is a heat demand.

#

Description

U08

When On-Off Room thermostat is connected and
outdoor sensor is not connected, this parameter value
is the central heating water temperature setpoint when
there is not a heat demand.

Note: 

For this parameter value to be active, reducing

mode has to be enabled by your service agent,
otherwise central heating mode will not be activated
when there is no het demand.

U09

If parameter is 1, comfort mode preheating will depend
on the user record. It will preheat the water according to
the previous day user records.

If parameter is 2, comfort mode preheating will be
independent of the user record, and at the highest
comfort level (3-star comfort according to EN 13302).

If parameter is 24, comfort mode preheating will be
independent of the user record.

Note: 

If you increase the comfort level, the energy

consumption increases.

U10

Room temperature setpoint used by Daikin Opentherm
room thermostat during night mode. Only visible in case
Daikin Opentherm room thermostat is connected.

t00

(a)

t01

(a)

t02

(a)

t03

(a)

t04

(a)

The date and time are set by means of t parameters to
update the LAN adapter. This is needed in case the
LAN adapter does not have internet connection.

Time and date settings is saved when menu is quitted
by pressing (back) button.

After date and time are set, UH-08 error disappears.

(a)

Applicable if energy metering is enabled.

To use the user settings menu

1

Press  the  "Enter"  button  when  the 

  icon  is  displayed  on  the

menu level 1 screen.

Result: 

You can see the parameter values on menu level 2.

2

Select U or t parameters with the left dial.

3

Select the index with the right dial.

4

Press  the  "Enter"  button  when  the  parameter  that  you  want  to
change is displayed.

Result: 

You  can  see  the  menu  level  3  screen.  Up  and  down

arrows will appear.

5

Change the parameter with the right dial.

6

Press  the  "Enter"  button  to  confirm  or  the  "Cancel"  button  to
cancel. You will return to menu level 2 after pressing "Enter" or
"Back"

3.5.4

Installer settings menu

Only  qualified  persons  are  allowed  to  enter  the  installer  settings
menu.

Summary of Contents for D2C24ND035A5AA

Page 1: ...Operation manual Wall mounted condensing boiler English Manuel de fonctionnement Chaudi re murale condensation Fran ais Operation manual Wall mounted condensing boiler D2C20ND028A5AA D2C24ND035A5AA...

Page 2: ...right cover of the unit See table below Model Type Domestic hot water supply D2C20ND028A5AA D2C20ND028 Instantaneous D2C24ND035A5AA D2C24ND035 Instantaneous A control unit which contains a user interf...

Page 3: ...Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is...

Page 4: ...ler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central h...

Page 5: ...Operation mode Description Summer mode Only domestic hot water operation mode is enabled Central heating operation mode is disabled The boiler will only produce heat for domestic hot water The domest...

Page 6: ...rature setpoint can be adjusted by means of left dial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons...

Page 7: ...ICE When not using the boiler we strongly recommend not to cut off the electric supply to the boiler 3 3 10 About Energy Metering Function This function provides user to read electricity and gas consu...

Page 8: ...ric energy consumption Domestic hot water Last month kWh Description short Unit F42 d Electric energy consumption Domestic hot water Current month kWh F43 d Electric energy consumption Domestic hot wa...

Page 9: ...For this parameter value to be active reducing mode has to be enabled by your service agent otherwise central heating mode will not be activated when there is no heat demand U07 When On Off room therm...

Page 10: ...lution 10 64 Gas valve circuit error Perform reset If problem repeats contact your service agent 10 65 Gas valve current error Perform reset If problem repeats contact your service agent 11 64 Ignitio...

Page 11: ...the system pressure to 0 8 bar HJ 10 Water pressure sensor fault Contact your service agent J6 01 Flow temperature sensor overheating Can be a blocking error or a lockout error Check the valves of the...

Page 12: ...u uniquement pour le chauffage central Le type d alimentation d eau chaude peut tre instantan ou par l interm diaire d un r servoir de stockage d eau chaude Les chaudi res uniquement chauffantes ne fo...

Page 13: ...aintenance ou une r paration vous m me Faites appel un agent d entretien qualifi ATTENTION N utilisez pas de sprays de solvants d agents de nettoyage chlor s de peinture et d adh sifs proximit de l un...

Page 14: ...les param tres du menu L cran cristaux liquides dispose d une fonction de veille Au bout d une minute de non interaction avec l interface utilisateur l cran s assombrit Appuyer sur un des boutons ou t...

Page 15: ...d eau chaude sanitaire Il s agit du comportement habituel 3 3 Utilisation de base 3 3 1 propos de l cran d accueil Il s agit de l cran qui s affiche apr s l activation de l cran cristaux liquides l a...

Page 16: ...de consigne de la temp rature peuvent tre modifi s l aide des molettes gauche droite Modification du point de consigne de la temp rature du chauffage central 1 Tournez la molette gauche en tant l cran...

Page 17: ...u chauffage central est activ REMARQUE En cas de conception mauvaise ou inadapt e du circuit de chauffage central qui provoquerait un d gagement de chaleur inad quat dans l espace de s jour activer le...

Page 18: ...t le statut de l indicateur de statut est affect Cependant veuillez noter que toutes les erreurs n ont pas le m me effet sur l interface utilisateur et l indicateur de statut Type d erreur Fonctionnem...

Page 19: ...ommation d nergie lectrique eau chaude sanitaire mois actuel kWh F43 d Consommation d nergie lectrique eau chaude sanitaire ann e actuelle kWh a Ne s applique pas si le capteur n est pas raccord b Val...

Page 20: ...rature int rieure virtuelle s il n y a pas de demande de chauffage Note Pour que cette valeur de param tre soit active le mode de r duction doit tre activ par votre agent d entretien autrement le mode...

Page 21: ...volets la nuit Ne cachez pas de radiateurs derri re de grands meubles c est dire un canap un bureau etc Il faut garder une distance d au moins 50 cm sinon l air chaud ne peut pas circuler et la pi ce...

Page 22: ...e circuler Votre chaudi re fonctionnera nouveau au bout d un moment Si le probl me se r p te contactez votre agent d entretien 8H 65 Diff rence de temp rature d part retour trop lev e Veillez ce que l...

Page 23: ...nexion du thermostat d ambiance Opentherm est d fectueuse Votre chaudi re continuera fonctionner mais le thermostat d ambiance Opentherm est hors service Contactez votre agent d entretien U4 66 Expira...

Page 24: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469438 10H 2018 05...

Reviews: