background image

Table of Contents

Operation manual

2

D2C20ND0 D2C24ND035A5AA

Wall-mounted condensing boiler

3P469438-10H – 2018.05

Table of Contents

1 Introduction

2

1.1

About the unit ............................................................................

2

1.2

About the documentation ..........................................................

2

1.2.1

Meaning of warnings and symbols..............................

2

2 Safety instructions

2

2.1

Installation .................................................................................

2

2.2

Smell of gas...............................................................................

3

2.3

Modifications on the unit............................................................

3

2.4

Gas conversion .........................................................................

3

2.5

For the user ...............................................................................

3

3 Operation

3

3.1

User interface ............................................................................

3

3.1.1

Buttons and dials ........................................................

3

3.1.2

LCD screen .................................................................

4

3.1.3

Status indicator ...........................................................

4

3.2

Operating the unit......................................................................

4

3.2.1

To switch ON the unit..................................................

4

3.2.2

About the low water temperature function ..................

4

3.2.3

About the electronic gas adaptive system calibration .

4

3.3

Basic usage ...............................................................................

5

3.3.1

About the home screen...............................................

5

3.3.2

To select the operation mode .....................................

5

3.3.3

Possible operation modes...........................................

5

3.3.4

Changing temperature setpoints.................................

5

3.3.5

Possible central heating operation modes ..................

6

3.3.6

About the central heating ECO mode .........................

6

3.3.7

About the domestic hot water operation .....................

6

3.3.8

About the domestic hot water comfort mode ..............

7

3.3.9

About the boiler frost protection ..................................

7

3.3.10

About Energy Metering Function ................................

7

3.4

Error handling ............................................................................

7

3.5

Menu functions ..........................................................................

7

3.5.1

To use menu level 1....................................................

7

3.5.2

Info menu ....................................................................

8

3.5.3

User settings menu .....................................................

8

3.5.4

Installer settings menu ................................................

9

4 Maintenance and cleaning

10

4.1

To clean the outer surface of the unit........................................

10

5 Energy saving tips

10

6 Contact

10

7 Error codes

10

1

Introduction

1.1

About the unit

This  Daikin  unit  is  a  wall-mounted  gas-fired  condensing  boiler  that
can  supply  heat  to  central  heating  systems,  as  well  as  supply
domestic hot water. Depending on settings, it is possible to use the
unit  solely  for  hot  water  or  solely  for  central  heating.  Hot  water
supply  type  can  be 

instantaneous

  or  by  means  of  a  hot  water

storage  tank

.

  Heating  only

  boilers  do  not  supply  domestic  hot

water.  The  type  of  the  boiler  can  be  recognised  from  the  model
name written on the identification label, which is located at the right
cover of the unit. See table below:

Model

Type

Domestic hot water

supply

D2C20ND028A5AA

D2C20ND028

Instantaneous

D2C24ND035A5AA

D2C24ND035

Instantaneous

A control unit, which contains a user interface, controls the ignition,
safety systems, and other actuators. User interaction is provided via
that  user  interface,  which  is  composed  of  an  LCD  screen,  push
buttons, and two dials, and which is located on the front cover of the
unit.

1.2

About the documentation

The  instructions  contained  in  this  document  are  intended  to  guide
you  through  the  operation  of  the  unit.  Damage  caused  by  non-
observance  of  these  instructions  are  not  under  the  responsibility  of
Daikin.

▪ The  original  documentation  is  written  in  English.  All  other

languages are translations.

▪ The  precautions  described  in  this  document  are  written  for  users

and cover very important topics, follow them carefully.

▪ Please  read  the  instructions  in  the  manual  carefully,  for  your

safety and health.

▪ Please keep this manual for future reference throughout the unit's

period of use.

▪ Request  the  installer  to  inform  you  about  the  settings  that  he

made to configure your system.

1.2.1

Meaning of warnings and symbols

DANGER

Indicates a situation that results in death or serious injury.

WARNING

Indicates  a  situation  that  could  result  in  death  or  serious
injury.

CAUTION

Indicates a situation that could result in minor or moderate
injury.

NOTICE

Indicates  a  situation  that  could  result  in  equipment  or
property damage.

INFORMATION

Indicates useful tips or additional information.

2

Safety instructions

Always observe the following safety instructions and regulations.

2.1

Installation

WARNING

Installation,  service,  maintenance  and  repair  of  the  boiler
can  only  be  carried  out  by  suitably  qualified  competent
persons,  in  accordance  with  the  applicable  legislation,
regulations, rules and guidelines.

WARNING

The  unit  may  only  be  operated  with  its  casing  properly
mounted.  Otherwise,  in  unfavourable  conditions,  material
damage or even injury or death can result.

CAUTION

A  discharge  pipe  must  be  connected  to  the  condensate
trap in order to prevent contact with the condensate.

Summary of Contents for D2C24ND035A5AA

Page 1: ...Operation manual Wall mounted condensing boiler English Manuel de fonctionnement Chaudi re murale condensation Fran ais Operation manual Wall mounted condensing boiler D2C20ND028A5AA D2C24ND035A5AA...

Page 2: ...right cover of the unit See table below Model Type Domestic hot water supply D2C20ND028A5AA D2C20ND028 Instantaneous D2C24ND035A5AA D2C24ND035 Instantaneous A control unit which contains a user interf...

Page 3: ...Boiler Gas water or power supply Flue system 2 4 Gas conversion WARNING Never attempt to do gas conversion yourself Only qualified persons can do gas conversion Contact your service agent This unit is...

Page 4: ...ler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central h...

Page 5: ...Operation mode Description Summer mode Only domestic hot water operation mode is enabled Central heating operation mode is disabled The boiler will only produce heat for domestic hot water The domest...

Page 6: ...rature setpoint can be adjusted by means of left dial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons...

Page 7: ...ICE When not using the boiler we strongly recommend not to cut off the electric supply to the boiler 3 3 10 About Energy Metering Function This function provides user to read electricity and gas consu...

Page 8: ...ric energy consumption Domestic hot water Last month kWh Description short Unit F42 d Electric energy consumption Domestic hot water Current month kWh F43 d Electric energy consumption Domestic hot wa...

Page 9: ...For this parameter value to be active reducing mode has to be enabled by your service agent otherwise central heating mode will not be activated when there is no heat demand U07 When On Off room therm...

Page 10: ...lution 10 64 Gas valve circuit error Perform reset If problem repeats contact your service agent 10 65 Gas valve current error Perform reset If problem repeats contact your service agent 11 64 Ignitio...

Page 11: ...the system pressure to 0 8 bar HJ 10 Water pressure sensor fault Contact your service agent J6 01 Flow temperature sensor overheating Can be a blocking error or a lockout error Check the valves of the...

Page 12: ...u uniquement pour le chauffage central Le type d alimentation d eau chaude peut tre instantan ou par l interm diaire d un r servoir de stockage d eau chaude Les chaudi res uniquement chauffantes ne fo...

Page 13: ...aintenance ou une r paration vous m me Faites appel un agent d entretien qualifi ATTENTION N utilisez pas de sprays de solvants d agents de nettoyage chlor s de peinture et d adh sifs proximit de l un...

Page 14: ...les param tres du menu L cran cristaux liquides dispose d une fonction de veille Au bout d une minute de non interaction avec l interface utilisateur l cran s assombrit Appuyer sur un des boutons ou t...

Page 15: ...d eau chaude sanitaire Il s agit du comportement habituel 3 3 Utilisation de base 3 3 1 propos de l cran d accueil Il s agit de l cran qui s affiche apr s l activation de l cran cristaux liquides l a...

Page 16: ...de consigne de la temp rature peuvent tre modifi s l aide des molettes gauche droite Modification du point de consigne de la temp rature du chauffage central 1 Tournez la molette gauche en tant l cran...

Page 17: ...u chauffage central est activ REMARQUE En cas de conception mauvaise ou inadapt e du circuit de chauffage central qui provoquerait un d gagement de chaleur inad quat dans l espace de s jour activer le...

Page 18: ...t le statut de l indicateur de statut est affect Cependant veuillez noter que toutes les erreurs n ont pas le m me effet sur l interface utilisateur et l indicateur de statut Type d erreur Fonctionnem...

Page 19: ...ommation d nergie lectrique eau chaude sanitaire mois actuel kWh F43 d Consommation d nergie lectrique eau chaude sanitaire ann e actuelle kWh a Ne s applique pas si le capteur n est pas raccord b Val...

Page 20: ...rature int rieure virtuelle s il n y a pas de demande de chauffage Note Pour que cette valeur de param tre soit active le mode de r duction doit tre activ par votre agent d entretien autrement le mode...

Page 21: ...volets la nuit Ne cachez pas de radiateurs derri re de grands meubles c est dire un canap un bureau etc Il faut garder une distance d au moins 50 cm sinon l air chaud ne peut pas circuler et la pi ce...

Page 22: ...e circuler Votre chaudi re fonctionnera nouveau au bout d un moment Si le probl me se r p te contactez votre agent d entretien 8H 65 Diff rence de temp rature d part retour trop lev e Veillez ce que l...

Page 23: ...nexion du thermostat d ambiance Opentherm est d fectueuse Votre chaudi re continuera fonctionner mais le thermostat d ambiance Opentherm est hors service Contactez votre agent d entretien U4 66 Expira...

Page 24: ...MA S STEMLER SAN T C A K kbakkalk y Mah Kay da Cad No 1 Kat 21 22 34750 Ata ehir STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr 3P469438 10H 2018 05...

Reviews: