background image

5 Operation

Operation manual

7

FTXTP-M_FTXTP-N
Daikin room air conditioners
3P717028-2B – 2023.03

The  movable  range  of  the  flap  varies  according  to  the  operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.

5.4.1

To adjust vertical airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  flaps  (horizontal  blades)

will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flaps  reach  the

desired position.

Result: 

  disappears  from  the  LCD.  The  flaps  will  stop

moving.

5.4.2

To adjust horizontal airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  louvers  (vertical

blades) will begin to swing.

2

To use fixed position, press 

 when the louvers reach the

desired position.

Result: 

  disappears  from  the  LCD.  The  louvers  will  stop

moving.

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

5.4.3

To use 3D airflow direction

1

Press 

 and 

.

Result: 

 and 

 appear on the LCD. The flaps (horizontal

blades) and louvers (vertical blades) will begin to swing.

2

To  use  fixed  position,  press 

  and 

  when  the  flaps

and louvers reach the desired position.

Result: 

  and 

  disappear  from  the  LCD.  The  flaps  and

the louvers will stop moving.

5.5

Comfort airflow operation

This operation can be used in 

heating

 or 

cooling

 operation mode. It

will provide a comfortable wind that will NOT come in direct contact
with people. The system automatically sets the fixed airflow position
upward in Cooling and downward in Heating operation mode.

Cooling operation mode

Heating operation mode

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  vertical  automatic  swing  is  selected,  Comfort  airflow
operation will be cancelled.

5.5.1

To start/stop Comfort airflow operation

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

Note: 

Comfort airflow operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

5.6

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

5.6.1

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

 Powerful operation can be set only when the unit is running. If

you press 

 or if you change operation mode, operation will be

cancelled; 

 disappears from the LCD.

5.7

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

5.7.1

To start/stop Econo operation

1

Press 

 to start.

Result: 

 is displayed on the LCD.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Summary of Contents for Comfora

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners FTXTP25M5V1B FTXTP35M5V1B FTXTP25N5V1B FTXTP35N5V1B...

Page 2: ...ing filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To close the front panel 11 7 9 To...

Page 3: ...icide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak I...

Page 4: ...l refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room whe...

Page 5: ...emove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wirel...

Page 6: ...Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the button one or more times to set the temperature...

Page 7: ...tic swing is selected Comfort airflow operation will be cancelled 5 5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the ai...

Page 8: ...ple If is set when the unit is NOT operating operation will start after 2 hours 3 To cancel the setting press Result and the time setting disappear from the LCD and the timer lamp goes off 5 8 3 To co...

Page 9: ...once a year However applicable legislation might require shorter maintenance intervals WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks...

Page 10: ...ct your dealer 1 Clean with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult...

Page 11: ...Part number Titanium deodorising filter KAF970A46 Silver particle filter KAF057A41 7 8 To close the front panel 1 Set the filters as they were 2 Gently press the front panel at both sides and at the c...

Page 12: ...n OFF the power supply The operation lamp flashes and you can check the error code by the wireless remote control To display the error code see the user reference guide Notify your installer and repor...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 2B 2023 03 Copyright 20...

Reviews: