background image

5 Operation

Operation manual

8

FTXTP-M_FTXTP-N

Daikin room air conditioners

3P717028-2B – 2023.03

5.8

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner off/on at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the wireless remote control.

5.8.1

To start/stop OFF timer operation

Use  this  feature  if  the  unit  is  operating  and  you  want  to  stop
operation after a certain time.

1

Press 

.

Result: 

  is  displayed  on  the  LCD  and  the  timer  lamp

lights up.

2

Press 

 again if you want to change the time setting.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

Example: 

 If 

 is set when the unit is operating, operation

will stop after 5 hours.

3

To cancel the setting, press 

.

Result: 

  and  the  time  setting  disappear  from  the  LCD  and  the

timer lamp goes off.

INFORMATION

Night set mode

When  the  OFF  timer  is  set,  the  air  conditioner
automatically  adjusts  the  temperature  setting  (0.5°C  up  in
cooling,  2.0°C  down  in  heating)  to  prevent  excessive
cooling/heating  and  ensure  a  comfortable  sleeping
temperature.

5.8.2

To start/stop ON timer operation

Use  this  feature  if  the  unit  is  NOT  operating  and  you  want  to  start
operation after a certain time.

1

Press 

.

Result: 

  is  displayed  on  the  LCD  and  the  timer  lamp

lights up.

2

Press 

 again if you want to change the time setting.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

Example: 

  If 

  is  set  when  the  unit  is  NOT  operating,

operation will start after 2 hours.

3

To cancel the setting, press 

.

Result: 

  and  the  time  setting  disappear  from  the  LCD  and  the

timer lamp goes off.

5.8.3

To combine OFF timer and ON timer

1

To  set  the  timers,  refer  to 

"5.8.1  To  start/stop  OFF  timer

operation"

  [

4

  8]  and 

"5.8.2  To  start/stop  ON  timer

operation"

 [

4

 8].

Result: 

 and 

 are displayed on the LCD.

Example:

2

If 

 is set when the unit is operating.

Result: 

Operation 

stops

  in  1  hour  and  then 

starts

  7  hours

later.

3

If 

  is  set  when  the  unit  is  NOT

operating.

Result: 

Operation 

starts

  in  2  hours  and  then 

stops

  3  hours

later.

5.9

Wireless LAN connection

Simply  connect  your  unit  to  your  home  network  and  download  the
app  to  change  the  thermostat,  set  temperature  schedules,  review
your energy consumption and more.

For details on specifications, setting methods, FAQ, troubleshooting
tips, visit 

app.daikineurope.com

.

The customer is responsible for providing:

▪ Smartphone or tablet with minimum supported version of Android

or iOS, specified on 

app.daikineurope.com

.

▪ Internet line and communication device, such as a modem, router,

etc.

▪ Wireless LAN access point

▪ Installed free ONECTA application

5.9.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

5.9.2

To install the ONECTA app

1

Go  to  Google  Play  (for  Android  devices)  or  the  App  Store  (for
iOS devices) and search for "ONECTA".

2

Follow the directions on the screen to install the ONECTA app.

INFORMATION

Scan  the  QR  code  to  download  and  install  the  ONECTA
app 

on 

your 

mobile 

phone 

or 

tablet:

Summary of Contents for Comfora

Page 1: ...Operation manual Daikin room air conditioners English Operation manual Daikin room air conditioners FTXTP25M5V1B FTXTP35M5V1B FTXTP25N5V1B FTXTP35N5V1B...

Page 2: ...ing filter and the silver particle filter Ag ion filter 10 7 7 To replace the titanium apatite deodorising filter and the silver particle filter Ag ion filter 11 7 8 To close the front panel 11 7 9 To...

Page 3: ...icide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak I...

Page 4: ...l refrigerant leaks make sure there are no naked flames The refrigerant itself is entirely safe non toxic and mildly flammable but it will generate toxic gas when it accidentally leaks into a room whe...

Page 5: ...emove the back cover 2 Insert both batteries at once 3 Put the cover back 2 3 1 AAA LR03 4 2 To mount the wireless remote control holder c b a 2 a Wireless remote control b Screws field supply c Wirel...

Page 6: ...Press Result Automatic operation The operation lamp lights up Cooling operation Drying operation Heating operation Fan only operation 2 Press or on the button one or more times to set the temperature...

Page 7: ...tic swing is selected Comfort airflow operation will be cancelled 5 5 1 To start stop Comfort airflow operation 1 Press to start Result The flap position will change is displayed on the LCD and the ai...

Page 8: ...ple If is set when the unit is NOT operating operation will start after 2 hours 3 To cancel the setting press Result and the time setting disappear from the LCD and the timer lamp goes off 5 8 3 To co...

Page 9: ...once a year However applicable legislation might require shorter maintenance intervals WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks...

Page 10: ...ct your dealer 1 Clean with a soft cloth If it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult...

Page 11: ...Part number Titanium deodorising filter KAF970A46 Silver particle filter KAF057A41 7 8 To close the front panel 1 Set the filters as they were 2 Gently press the front panel at both sides and at the c...

Page 12: ...n OFF the power supply The operation lamp flashes and you can check the error code by the wireless remote control To display the error code see the user reference guide Notify your installer and repor...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P717028 2B 2023 03 Copyright 20...

Reviews: