Safety Warning

This manual provides information on the control data of the Clima Flex  CLIV  series. 

NOTES:

 Installation and maintenance must be performed only by qualified personnel who are familiar with local codes and regulations and 

who have experience with this type of equipment.

DANGER

 

!

LOCK OUT/LABEL all power sources before starting, pressurizing, depressurizing or shutting down the chiller. 
Disconnect electrical power before servicing equipment. More than one disconnection may be required to deenergize the unit. Fail-

ure to follow this warning to the letter can result in serious injury or death. Be sure to read and understand the installation, operating 

and service instructions in this manual.

!

 

DANGER 

!

Danger indicates a dangerous situation which, if not avoided, will result in death or serious injury.

!

 WARNING 

!

Warning indicates a potentially dangerous situation which may result in property damage, personal injury or death if not avoided

CAUTION 

!

Caution indicates a potentially dangerous situation which may result in minor injury or equipment damage if not avoided.

WARNING

 !

Electric shock danger. Improper handling of this equipment can cause personal injury or equipment damage. This equipment must 

be properly grounded. Control panel connections and maintenance should be performed only by personnel knowledgeable in the 

operation of the equipment being controlled. Disconnect electrical power before servicing equipment.

!

 WARNING 

!

If refrigerant leaks from the unit, there is a potential choking danger as the refrigerant will displace air in the immediate area. Be 

sure to follow all applicable published industry-related standards and local, state, and federal statutes, regulations, and codes if 

refrigerant is produced. Avoid exposing refrigerant to an open flame or other ignition source.

WARNING 

!

Polyolester oil, commonly referred to as POE oil, is a synthetic oil used in many refrigeration systems and may be present in this 

Clima Flex  product. POE oil, if it ever comes in contact with PCV/CPVC, will coat the inside wall of the PVC/CPVC pipe and cause 

environmental stress fractures. Although there is no PCV/CPCV pipe in this product, keep this in mind when selecting piping mate-

rials for your application, as system failure and property damage could occur. Consult the pipe manufacturer’s recommendations to 

determine appropriate pipe applications.

!

 CAUTION 

!

Static sensitive components. Static discharge during handling of the electronic circuit board can cause damage to components. 

Use a static strap before performing any service work. Never unplug any cables, circuit board terminal blocks, or power plugs while 

power is applied to the panel.

!

 CAUTION 

!

When moving refrigerant to/from the cooler using an auxiliary tank, a grounding strap should be used. An electrical charge builds 

up when halo-carbon refrigerant travels in a rubber hose. A grounding strap should be used between the auxiliary refrigerant tank 

and the cooler end sheet (ground to ground), which will safely carry the charge to ground. Failure to follow this procedure may result 

in damage to sensitive electronic components.

DANGER IDENTIFICATION INFORMATION

Notes:

 Indicate important details or clarifying statements for the information presented.

Summary of Contents for Clima-Flex CLIV Series

Page 1: ...Control Manual CLIV Series Air Cooled Fixed Compressor Chiller Water Generator Unit Model 3 5 y 10 TR Refrigerant HFC 410A 50 60 Hz CM Group Chiller Part Number CM CLIV Date 10 November 2022...

Page 2: ...escription 4 Features Benefits 5 Control 7 2022 Clima Flex Illustration and data cover the Clima Flex product at the time of publication and we reserve the right to make changes in design and construc...

Page 3: ...tial choking danger as the refrigerant will displace air in the immediate area Be sure to follow all applicable published industry related standards and local state and federal statutes regulations an...

Page 4: ...120 000 AIR DISCHARGE HD Horizontal Discharge OPERATION C Cooling Only H Heat Pump UNITS 1 Stand alone CONDENSER FAN A Axial Fixed ANTICORROSION C Coat in Condenser I Coat in Components M Total Coati...

Page 5: ...t All main components are rigorously tested and validated before being installed Each designed unit has undergone long hours of rigorous testing to ensure the efficiency safety durability and quality...

Page 6: ...eas of the coating surface with no bridging of material between fins Therefore ES2 pigments are suitable for even the most Spray for coating hvac r products Ideal applications for Insitu spray applied...

Page 7: ...hows 3 digits with a decimal point between them only the decimal point will be shown in the range from 99 9 to 99 9 outside this range the values will be shown without decimal point using the 3 digits...

Page 8: ...larm The Flow Alarm is activated when Low Flow is detected to reset the alarm and correct the problem Reset the unit Turn the unit off and on A1 Freeze Alarm Temperature sensor B3 measures a temperatu...

Page 9: ...nnectivity with mobile devices and comes integrated on panel mounted models and is purchased separately on DIN rail mounted models The CAREL APPLICA app available on Google Play for the Android operat...

Page 10: ...lization At startup the user terminal briefly displays the text NFC which indicates the presence on the user terminal of the NFC interface for communication with mobile devices and then the standard d...

Page 11: ...maintenance intervention is required the alarm code indicates which device is concerned The reset of some alarms can be configured through a parameter The configurable alarms are High pressure switch...

Page 12: ...ontrol will be mentioned below These alarms will depend on the electrical configuration and the model of the equipment and depending on these configurations the alarms shown below may or may not depen...

Page 13: ...ress DOWN the unit on off command UnSt appears Press DOWN the command to change the cooling mode so Clo at Assistance level and for A W reversible units appears heating H ModE only for heat pump units...

Page 14: ...l address Electrical diagram label Name ID1 IF Flow sensor ID2 C H Heating cooling switch ID3 AP High pressure switch ID4 BP Low pressure switch ID5 System DAC HDunit ON OFF switch Tabla 2 Digital inp...

Page 15: ...cm cliv cf eng www clima flex com 15 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...cm cliv cf eng www clima flex com...

Reviews: