background image

3P257556-2A        English

2

3.  Accessory

Check that the following accessories provided with the air 
conditioner are correct in number. See the following illustration, 
which shows where the accessories are kept.

Backside of the protective 

corrugated cardboard

A set of accessories
The accessories are 

on the backside of the 

protective corrugated 

cardboard under 

the suction grille.

Suction grille

Name

Spacer 

(1)

Flexible 

hose (2)

S-shaped 

pipe (3)

Harness (4)

Clamp 

(5)

Quantity

1 pc.

1 pc.

1 pc.

1 pc.

2 pcs.

Shape

Name

Seal (6)

Others

Quantity

1 pc.

Shape

 

Operation manual

 

Installation manual

Pay the utmost attention to the following items when 
conducting installation work, and recheck the items on 
completion of the work.

a.  Test items on completion of work

Test items

In case of failure Result

Is the air conditioner free of wiring and 
connection mistakes or omissions?

Operation failure 

and wire burnout

Are you sure that there is no space 
between the ceiling and ceiling material?

Water leakage

Are the fixing knobs (in 2 points) of the 
dust box secured tightly?

Vibration, noise, 

and dust 

collection failure

Are the fixed knobs (in 5 points) of the 
air filter secured tightly?

Vibration, noise, 

and dust 

collection failure

Is the fall prevention cord for the dust 
box and grille hooked to the mounting 
bracket?

Fall

Did you attach the control box cover, 
dust box, flexible hose, S-shaped pipe, 
suction grille, and decoration corner 
covers?

Noise and dust 

collection failure

 

* Be sure to recheck the items provided in the section "1. Safety 

Considerations" on page i.

b. Test items before delivery

Test items

Result

Was the test operation of the air conditioner finished?
Did you explain the operation method of the air 
conditioner to the customer while showing the customer 
the operation manual? *
Did you make mode settings for filter auto-cleaning 
(automatic control operation settings or timer operation 
settings with an operation time zone specified) and 
provide information on the set mode operation of the air 
conditioner to the customer?
Did you deliver the operation manual to the customer? 
(Be sure to hand the customer the operation manual as 
well as the installation manual.)

 

*

Point of operation explanation

In addition to the general usage of the air conditioner, it is 
necessary to explain the descriptions of the 

 WARNING and 

 CAUTION marked items in the operation manual and have 

the customer read the descriptions carefully, because these 
items indicate information that, if not heeded, is likely to result in 
loss of life, serious injury, or property damage.

4.  Installation Site

This product offers selectable air outlet directions. A closure kit (an 
optional accessory) is required to achieve three-way flow patterns. 
Two-way flow patterns are not available to this product.

4-1  Select the installation site that meets the 

following conditions with the consent of the 

customer

 

The surface of the ceiling is not inclined.

 

Installation and service workspace is secured (see the following 
illustrations).

 

The panel indicators are seen with ease.

 

The indoor and outdoor units, power cord, transmission wiring, 
and remote controller wiring are at least 1 m away from TV or 
radio sets. 
(The above is for the prevention of TV and radio interference. 

Depending on the incoming signal strength, a distance of 1 m 

may not be sufficient to eliminate noise.)

3P257556-2A.indb   2

12/16/2013   4:27:53 PM

Summary of Contents for BYCQ125BGW1

Page 1: ...Decoration Panel Provided with Filter Auto cleaning Function Self Cleaning Decoration Panel INSTALLATION MANUAL BYCQ125BGW1 3P257556 2A 3P257556 2A indb 1 12 16 2013 4 27 52 PM ...

Page 2: ... carry the product Do not carry the package with the polypropylene band on the package held which will be dangerous because the polypropyl ene band may be deformed Do not touch the fin of the heat exchanger Touching the fin improperly may result in injury Do not turn the product power off immediately after the operation of the product comes to a stop Always wait for at least 5 minutes before turni...

Page 3: ...r Panel 4 6 Preparations for Indoor Unit 5 7 Attaching Panel to Indoor Unit 6 8 Attaching Suction Grille and Decoration Corner Covers 9 9 Operation Mode Settings 11 10 Field Settings 11 11 Test Operation 12 The English text is the original instruction Other languages are translations of the original instructions 3P257556 2A indb 1 12 16 2013 4 27 52 PM ...

Page 4: ...s Result Was the test operation of the air conditioner finished Did you explain the operation method of the air conditioner to the customer while showing the customer the operation manual Did you make mode settings for filter auto cleaning automatic control operation settings or timer operation settings with an operation time zone specified and provide information on the set mode operation of the ...

Page 5: ...lighting applies to exposed models e g models of inverted mountain type and there are no restrictions on embedded models with no protrusion from the ceiling surface 3 If the air discharge outlet is closed or the wind direction of the swing flaps are changed to block the wind the space marked with the asterisk will be 20 in 500 mm or over The space will be 8 in 200 mm or over if the air discharge o...

Page 6: ...tective corrugated cardboard Protective corrugated cardboard top The accessories are on the backside Protective corrugated cardboard bottom Note Do not impose force on the swing flap brush unit or air filter when handling the panel Panel Brush unit Air filter Swing flap 5 2 Removal of decoration corner covers Panel Decoration corner cover Decoration corner cover Decoration corner cover Decoration co...

Page 7: ... after installing the indoor unit Install the indoor unit according to the installation manual provided with the indoor unit 6 1 Attaching spacer accessory 1 1 Remove the bypass hole closing cap 1 2 1 Indoor unit 2 Remove the bypass hole closing cap 2 Peel off the release paper of the double stick tape on the backside of the spacer accessory 1 3 Attach the spacer accessory 1 on the air bypass hole...

Page 8: ... panel on the internal circumference side to the hooks of the indoor unit Note Let go your hands after confirming through the check window that the temporary latching brackets are engaged with the hooks 2 Remove from the harness opening as described in 6 Preparations for Indoor Unit on page 5 Pull out the lead wires disconnected from the decoration cover in the corner carefully so that lead wries ...

Page 9: ...e seal of panel 2 Insert the seal until the seal comes in contact with the clamp 3 Clamp 4 Sealing accessory 6 2 Draw the harness and lead wires on the panel side Panel Harness Harness Lead wire on the panel side Lead wire on the panel side 3 Connect the connector of the lead wires and move the glass tube to cover the connector part Lead wire on the panel side Harness Connector Be sure to connect ...

Page 10: ...illustration 1 2 3 4 5 1 Clasp 2 Hooked fall prevention cord 3 Panel 4 Fall prevention cord 5 Dust box 2 Attach the dust box in the order opposite to the procedure in 5 3 Removal of dust box on page 4 Note Make sure that the fall prevention cord is not caught by the exhaust opening on the dust box when attaching the dust box Otherwise the dust box may not function normally 3 Turn the fixing knobs ...

Page 11: ...vention cord 3 Connect the flexible hose accessory 2 onto the panel side The flexible hose accessory 2 has no directionality constraint Flexible hose junction on the panel side Flexible hose accessory 2 Flexible hose junction on the panel side Fit the clamps into the hooks in two points securely Hooks 2 points Note Check that the clamps are engaged securely Otherwise a dust collection failure may ...

Page 12: ...flexible hose accessory 2 has no directionality constraint Flexible hose junction on the panel side Fit the clamps into the hooks in 2 points securely Flexible hose accessory 2 Flexible hose junction on the panel side Hooks 2 points Note Check that the clamps are engaged securely Otherwise a dust collection failure may result 4 Press fit the flexible hose connected in 3 into the panel Make sure th...

Page 13: ...owing operation modes can be selected for the filter auto cleaning of the self clean panel Operation mode Description 1 Scheduled timer operation Performs filter auto cleaning during the designated period selected from eight periods 2 00 00 to 03 00 operation Performs filter auto cleaning during the factory set period of time 00 00 to 03 00 3 Auto control operation Performs filter auto cleaning ac...

Page 14: ...th the remote controller Test operation method with remote controller 1 Stop the operation of the panel if the panel is in air conditioning operation 2 Continue pressing the Cancel button at least 4 seconds while the backlight is lit The service settings menu will appear 3 Select Test Filter Auto Clean from the service settings menu and press the Menu Enter button 4 will appear on the basic screen...

Page 15: ...3P257556 2A indb 13 12 16 2013 4 28 10 PM ...

Page 16: ...3P257556 2A EM13A021 1401 FS 3P257556 2A indb 1 12 16 2013 4 28 11 PM ...

Reviews: