5

English

9

FAN SPEED CONTROL BUTTON

Press this button to select the fan speed, 
Low or Middle or High, of your choice.

10

TEMPERATURE SETTING BUTTON

Use this button for SETTING TEM-
PERATURE (Operates with the front 
cover of the remote controller closed.)

11

SIGNAL TRANSMITTER

This sends the signals to the indoor 
unit.

12

TEMPERATURE ADJUSTMENT/ 
PROGRAMMING TIMER BUTTON

Use this button for temperature setting 
and programming “START and/or 
STOP” time. (Operates with the front 
cover of the remote controller opened.)

13

TIMER MODE START/STOP BUT-
TON

Refer to page 12.

14

TIMER RESERVE/CANCEL BUTTON

Refer to page 12.

15

AIRFLOW DIRECTION ADJUST 
BUTTON

Refer to page 10.

16

OPERATION MODE SELECTOR 
BUTTON

Press this button to select OPERA-
TION MODE. “

” (COOLING), “

” 

(HEATING), “

” (AUTOMATIC), 

” (FAN),

 

 (PROGRAM DRY).

17

FILTER SIGN RESET BUTTON

Refer to the section of MAINTE-
NANCE in the operation manual 
attached to the indoor unit.

18

INSPECTION/TEST OPERATION 
BUTTON

This button is used only by qualified ser-
vice persons for maintenance purposes.
Do not operate this button during nor-
mal use.

19

EMERGENCY OPERATION SWITCH

This switch is readily used if the 
remote controller does not work.

20

RECEIVER

This receives the signals from the 
remote controller.

21

OPERATING INDICATOR LAMP (Red)

This lamp stays lit while the air 
conditioner runs. It flashes when the 
unit is in trouble.

22

TIMER INDICATOR LAMP (Green)

This lamp stays lit while the timer is 
set.

23

AIR FILTER CLEANING TIME 
INDICATOR LAMP (Red)

Lights up when it is time to clean the 
air filter.

24

DEFROST OPERATION LAMP 
(Orange)

Lights up when the defrosting opera-
tion has started. (For cooling  only type 
this lamp does not turn on.)

NOTES

For the sake of explanation, all indica-
tions are shown on the display in Figure 1 
contrary to actual running situations.

Fig. 1-2 shows the remote controller with 
the front cover opened.

If the AIR FILTER CLEANING TIME 
INDICATOR LAMP lights up, clean the air 
filter as explained in the operation man-
ual provided with the indoor unit.
After cleaning and reinstalling the air fil-
ter, press the FILTER SIGN RESET BUT-
TON on the remote controller.  The AIR 
FILTER CLEANING TIME INDICATOR 
LAMP on the receiver will go out.

The DEFROST OPERATION LAMP will 
flash when the power is turned on. This is 
not a malfunction.

Do not place the remote controller where 
subject to direct sunlight. LCD will get dis-
colored and may fail to display information.

[CAUTIONS]

Before cleaning, be sure to press the ON/
OFF BUTTON to shut OFF the power for 
safety.

01_EN_3P302565-1.fm  Page 5  Monday, February 13, 2012  4:09 PM

Summary of Contents for BRC7EB518

Page 1: ...um Nachschlagen auf Nous vous remercions pour votre acquisition de ce climatiseur Daikin Lisez attentivement ce manuel avant d utiliser le climatiseur Il vous expliquera comment vous servir correcteme...

Page 2: ...utilizar a unidade correctamente e ajud lo no caso de surgir qualquer problema Depois de ler o manual guarde o num local seguro a fim de o poder consultar caso venha a ser preciso Daikin Daikin klima...

Page 3: ...6 15 17 18 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr hr TEST 11 22 21 20 19 24 23 Fig 2 00_CV_3P302565 1_2 fm P...

Page 4: ...nterior para un uso seguro del sistema y para su mantenimiento PRIMA DELL USO Il presente manuale d uso fornisce esclusivamente istruzioni per l uso del telecomando via radio Per un uso sicuro del sis...

Page 5: ...las del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normativa local y nacional aplicable Specifiche di smaltimento Il climatizzatore contrassegnato con questo simbolo...

Page 6: ...d direct expo sure to cool or warm air from the air conditioner or to air that is too cool or too warm can be harmful to your phys ical condition and health When the air conditioner is malfunc tioning...

Page 7: ...hat case or otherwise a malfunction electric shock or fire may result Start or stop the air conditioner with the remote controller Never use the power supply breaker for this pur pose Otherwise it may...

Page 8: ...children plants or animals are not exposed directly to airflow from the unit as adverse effects may ensue Do not wash the air conditioner or the remote controller with water as this may result in elec...

Page 9: ...lamp near the receiving section on the main unit A malfunction may occur Watch your steps at the time of air fil ter cleaning or inspection High place work is required to which utmost attention must b...

Page 10: ...s receives the signals from the remote controller 21 OPERATING INDICATOR LAMP Red This lamp stays lit while the air conditioner runs It flashes when the unit is in trouble 22 TIMER INDICATOR LAMP Gree...

Page 11: ...ote controller holder to a wall or a pillar with the attached screw Make sure it transmits 3 HANDLING FOR WIRELESS REMOTE CONTROLLER 2 short beeps from the receiver indicates that the transmission is...

Page 12: ...B 15 to 15 5 RZQ200 DB 10 to 27 DB 14 to 21 WB 15 to 15 Refer to figure 1 on page 1 Operating procedure varies with heat pump type and cooling only type Contact your Daikin dealer to confirm your syst...

Page 13: ...no less than 5 minutes Water is leaking or there is something else wrong with the unit After settings are changed or operation is turned ON OFF make sure that the receiv ing tone of the indoor unit ma...

Page 14: ...operation Regarding outside air temperature and heating capacity The heating capacity of the air conditioner declines as the outside air temperature falls In such a case use the air conditioner in co...

Page 15: ...perature range of the remote controller is 16 C to 32 C After settings are changed or operation is turned ON OFF make sure that the receiv ing tone of the indoor unit makes a beep ing sound ADJUSTMENT...

Page 16: ...tdoor unit The air dis charge direction becomes hori zontal so that it does not blow directly toward your body B LEFT AND RIGHT DIRECTION Hold the tabs on edge louvers horizontal air flow direction ad...

Page 17: ...tone does not sound set the timer using steps to and then press the TIMER CANCEL BUTTON 1 TIMER 2 DOWN UP DOWN UP 3 RESERVE 4 CANCEL 1 3 For example When the timer is programmed to stop the system af...

Page 18: ...troller displays the OPERATION MODE only PRECAUTIONS FOR GROUP CON TROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM 2 Indoor unit Remote controller If the wired remote controller is used for operat...

Page 19: ...ndoor unit makes a long beeping sound An unavailable mode was set for the indoor unit during operation changeover control IV THE FAN SPEED IS DIFFERENT FROM THE SETTING Even if the FAN SPEED CONTROL B...

Page 20: ...n code that appears on the display Contact your dealer with this code It will help pinpoint the cause of the trouble speeding up the repair 7 HOW TO DIAGNOSE TROU BLE SPOTS Set at 26 to 28 C for the C...

Page 21: ...batteries in the remote controller Place the batteries Check if the indoor unit number and wireless remote controller number are equal Operate the indoor unit with the remote con troller of the same...

Page 22: ...shock and or fire Trouble The OPERATING INDICATOR LAMP of the indoor unit is flashing and the unit does not work at all Refer to page 5 Remedial action Check the malfunction code A1 UF on the remote...

Page 23: ...3P302565 1 EM11A054 1111 HT 00_CV_3P302565 1_1 fm Page 2 Tuesday January 31 2012 3 14 PM...

Reviews: