Daikin BRC1H51W Installer And User Reference Manual Download Page 7

6 Operation

Installer and user reference guide

7

BK+S
Wired remote controller
4P513689-1 – 2018.02

3

Press 

 to confirm.

Result: 

The  indoor  unit  changes  its  airflow  direction  and  the

controller returns to the home screen.

6.3.2

Fan speed

The fan speed is the strength of the airflow coming out of the indoor
unit.

About fan speed

Depending on the indoor unit, you can choose between either:

Fan speed

Screen

2 fan speeds

3 fan speeds

5 fan speeds

Some  indoor  units  additionally  support  Automatic  fan  speed.  In  this
case,  the  indoor  unit  adjusts  its  fan  speed  automatically,  according
to the setpoint and indoor temperature.

Fan speed

Screen

Automatic

INFORMATION

▪ For  mechanical  protection  purposes,  it  is  possible  that

the  indoor  unit  switches  itself  to  'Automatic  fan  speed'
mode.

▪ If  the  fan  stops  operating,  this  does  not  necessarily

mean system failure. The fan can stop operating at all
times.

▪ It  may  take  some  time  before  changes  made  to  fan

speed settings are actually carried out.

To set the fan speed

1

Navigate to the fan speed menu.

2

Use 

 and 

 to adjust the fan speed.

3

Press 

 to confirm.

Result: 

The  indoor  unit  changes  its  fan  speed  and  the  controller

returns to the home screen.

6.4

Ventilation

INFORMATION

Ventilation  settings  can  ONLY  be  made  for  heat  reclaim
ventilation units.

6.4.1

Ventilation mode

The  heat  reclaim  ventilation  unit  can  operate  in  various  operation
modes.

Icon

Ventilation mode

Energy Reclaim Ventilation. 

The outdoor air is

supplied to the room after passing through a heat
exchanger.

Bypass. 

The outdoor air is supplied to the room

without passing through a heat exchanger.

Auto. 

To ventilate the room in the most efficient way,

the heat reclaim ventilation unit automatically
switches between "Bypass" and "Energy Reclaim
Ventilation" mode (based on internal calculations).

INFORMATION

Depending  on  the  heat  reclaim  ventilation  unit,  more  or
less ventilation modes are available.

NOTICE

Before starting up the system, the unit MUST be energised
for at least 6 hours to avoid compressor breakdown during
startup.

INFORMATION

To ensure a smooth start, do not turn off the system while
it is operating.

To set the ventilation mode

1

Navigate to the ventilation mode menu.

2

Use 

 and 

 to select a ventilation mode.

3

Press 

 to activate.

Result: 

The heat reclaim ventilation unit changes its operation mode

and the controller returns to the home screen.

Summary of Contents for BRC1H51W

Page 1: ...Installer and user reference guide Wired remote controller English Installer and user reference guide Wired remote controller BRC1H51W BRC1H51K BRC1H51S...

Page 2: ...Information 12 12 4 1 Information screen 12 12 4 2 Information menu 13 13 Configuration 13 13 1 Installer menu 13 13 1 1 About the installer menu 13 13 1 2 Screen settings 13 13 1 3 Status indicator s...

Page 3: ...ls In places with temperatures 10 C and 50 C In places where the relative humidity is 95 In places where there is machinery that emits electromagnetic waves Electromagnetic waves may disturb the contr...

Page 4: ...ng with a mobile device for use with the Daikin Control Assistant app Centralised control Indicates that the system is controlled by central control equipment optional accessory and that control of th...

Page 5: ...g or cooling Dry In this mode the air humidity will be lowered with a minimal temperature decrease The temperature and fan speed are controlled automatically and cannot be controlled by the controller...

Page 6: ...unit fan will automatically operate until the indoor temperature of the system rises to a certain level When hot air stays under the ceiling and your feet feel cold it is recommended to include a cir...

Page 7: ...to confirm Result The indoor unit changes its fan speed and the controller returns to the home screen 6 4 Ventilation INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation un...

Page 8: ...ntroller only allows for basic operation For advanced operation use the Daikin Control Assistant app 6 5 1 To make a Bluetooth connection Prerequisite You have a mobile device on which the Daikin Cont...

Page 9: ...nsists of the following stages 1 Determining how you want to route the electrical wiring and nipping away a piece of the rear casing accordingly 2 Mounting the rear casing to the wall 3 Connecting the...

Page 10: ...included NOTICE When wiring run the wiring away from the power supply wiring in order to avoid receiving electric noise external noise INFORMATION P1 and P2 have no polarity 10 3 2 To connect the ele...

Page 11: ...ill cause the adapter to go in error The controller gets its power from the indoor unit It will start up as soon as it is connected For the controller to be operable therefore make sure the indoor uni...

Page 12: ...de c Setpoint temperature Home screen mode is set with remote controller field setting R1 7 Home screen For more information see Remote controller field settings on page 18 Backlight The screen backli...

Page 13: ...instructions on how to enter the information menu see 13 1 Installer menu on page 13 and Information on page 25 13 Configuration 13 1 Installer menu 13 1 1 About the installer menu In the installer m...

Page 14: ...ons on how to make field settings see 13 1 4 Field settings on page 14 For an overview of remote controller field settings see Remote controller field settings on page 18 To set status indicator inten...

Page 15: ...In the field settings tables find the mode numbers that apply to individual indoor units between brackets in the Mode column Second level Setting SW A setting is a settable parameter These are the se...

Page 16: ...ng component 3 Use and to change the value of that field setting component 4 Press to confirm that value 5 In the first level select to move to the second level 6 In the second level navigate and sele...

Page 17: ...tenant 02 Thermostat differential if the system contains a remote sensor set the increase decrease increments 1 C 0 5 C 13 23 00 High air outlet velocity set in case of high ceiling applications h 2...

Page 18: ...ed 1 Standard 1 8 Backlight no operation timer 0 5 seconds 1 10 seconds 2 20 seconds 0 9 Status indicator faintness 0 0 OFF 1 1 2 2 3 3 4 5 5 7 6 9 7 11 8 13 9 15 10 17 11 20 9 10 Backlight faintness...

Page 19: ...fine groups and or units in the first level and set or release addresses for those groups and or units in the second Address Description First level Group Group A group is a group of indoor units When...

Page 20: ...utdoor units O U The Group address and AirNet address menu has two levels You define groups and or units in the first level and set and release an address for those groups and or units in the second A...

Page 21: ...tal input adapter see the installation manual of the digital input adapter In case the digital input adapter does not function properly the external input interlock menu is not available in the instal...

Page 22: ...ndoor unit s setpoint range and setpoint range limitation 22 C Reset Heat SP Default Reset Setting heating setpoint See indoor unit s setpoint range and setpoint range limitation 22 C INFORMATION When...

Page 23: ...n the delay timer will start running When the delay timer expires the reset timer will start running When the reset timer expires the previous state is updated to the Default Reset Setting state Examp...

Page 24: ...a controller displays Then NO status icon The indoor unit connected to that controller is Cooling Heating master a CONSTANT status icon The indoor unit connected to that controller is slave to a Cool...

Page 25: ...indoor unit is released from its masterhood Result The controllers of all indoor units display a blinking changeover under centralised control icon Information About the information menu In the infor...

Page 26: ...le cleaning the controller soak the cloth in neutral detergent diluted with water squeeze the cloth tightly and clean the surface Afterwards wipe dry with a dry cloth 14 2 About maintenance When the i...

Page 27: ...is available on the regional Daikin website publicly accessible The full set of latest technical data is available on the Daikin extranet authentication required 16 1 Connection diagram 16 1 1 Typical...

Page 28: ...eference guide 28 BRC1H51W K S Wired remote controller 4P513689 1 2018 02 Group control controller digital inputs adapter BRP7A5 0 1 2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 16 1 3 Controller DIII central cont...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...4P513689 1 2018 02 Copyright 2018 Daikin...

Reviews: