SiBE05-722ED
Troubleshooting
Service Diagnosis
96
Troubleshooting
RK(X)S25/35G2V1B, RK(X)S25/35G2V1B9, RXS25/35J2V1B, RXS25K3V1B, RXS35K2V1B,
RXS35L2V1B
Check No.17
Refer to P.105
Check No.19
Refer to P.106
Note:
Refer to Silicon Grease on Power Transistor / Diode Bridge on page 118 for detail.
Caution
Turn off the power and turn it on
again
to start the system.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
(R19529)
NO
NG
OK
NO
YES
Check the radiation fin
temperature.
NO
YES
YES
Above
A
˚C?
Check No. 19
Check the outdoor fan.
Error displayed again?
Has the PCB been
replaced?
Check if silicon grease is
applied properly on the
radiation fin. If not, apply
the silicon grease.
Replace the outdoor unit
PCB.
Replace the outdoor fan
motor.
Correct the connectors and
fan motor leads.
Replace the outdoor unit
PCB.
YES
NO
Radiation fin dirty?
Clean up the radiation fin.
Check the installation
condition.
Go to
Check No. 17
.
A
(°C)
RK(X)S25/35G2V1B
90
RK(X)S25/35G2V1B9
RXS25/35J2V1B
RXS25K3V1B
RXS35K2V1B
RXS35L2V1B
98