![background image](http://html1.mh-extra.com/html/daikin/ba-series/ba-series_service-manual_4200610046.webp)
Main Functions
SiBE05-722ED
35
Function and Control
Setting Temperature and Airflow Rate
When using HOME LEAVE operation for the first time, set your preferred temperature and
airflow rate for HOME LEAVE operation.
1. Press the
HOME LEAVE
button.
Make sure
is displayed on the remote controller.
2. Adjust the temperature with the
or
button.
3. Adjust the airflow rate with the
FAN
button.
HOME LEAVE operation will run with these settings the next time you start HOME LEAVE
operation. To change the recorded information, repeat steps 1 – 3.
Note:
1. The set temperature and airflow rate are recorded in the remote controller. When the remote
controller is reset due to battery replacement, the temperature and airflow rate for HOME
LEAVE operation needs to be set again.
2. The operation mode cannot be changed while HOME LEAVE operation is being used.
1.10 Inverter POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, the air conditioner can be
operated by increasing the indoor fan rotating speed and the compressor frequency.
Detail
When the
POWERFUL
button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A
= 50 rpm
Ex: POWERFUL operation in cooling
Initial setting
Selectable range
Temperature
Airflow rate
Temperature
Airflow rate
Cooling
25°C
18 ~ 32°C
5 steps,
,
Heating
25°C
10 ~ 30°C
5 steps,
,
Operation mode
Fan speed
Target temperature
COOL H
tap
+
A
rpm
18°C
DRY
Dry rotating speed +
A
rpm
Lowered by 2.5°C
HEAT
H tap +
A
rpm
30°C
FAN
H tap +
A
rpm
—
AUTO
Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R19177)
Target temp.
Fan
A
rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition:
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.