background image

Table of contents

Installation manual

4

AZQS100~14 AZQS100~140B7Y1B

Split system air conditioners

4P385528-1C – 2016.10

Table of contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Outdoor unit...............................................................................

4

2.1.1

To remove the accessories from the outdoor unit.......

4

3 Preparation

4

3.1

Preparing installation site ..........................................................

4

3.1.1

Installation site requirements of the outdoor unit ........

4

4 Installation

5

4.1

Mounting the outdoor unit..........................................................

5

4.1.1

To provide the installation structure ............................

5

4.1.2

To install the outdoor unit............................................

5

4.1.3

To provide drainage ....................................................

5

4.1.4

To prevent the outdoor unit from falling over ..............

6

4.2

Connecting the refrigerant piping ..............................................

6

4.2.1

To connect the refrigerant piping to the outdoor unit ..

6

4.2.2

To determine if oil traps are required ..........................

7

4.3

Checking the refrigerant piping .................................................

7

4.3.1

Checking refrigerant piping: Setup..............................

7

4.3.2

To check for leaks.......................................................

7

4.3.3

To perform vacuum drying ..........................................

7

4.4

Charging refrigerant ..................................................................

7

4.4.1

To determine the additional refrigerant amount ..........

7

4.4.2

To determine the complete recharge amount .............

8

4.4.3

Charging refrigerant: Setup.........................................

8

4.4.4

To charge refrigerant ..................................................

8

4.4.5

To fix the fluorinated greenhouse gases label ............

8

4.5

Connecting the electrical wiring.................................................

8

4.5.1

About electrical compliance ........................................

8

4.5.2

Specifications of standard wiring components............

8

4.5.3

To connect the electrical wiring on the outdoor unit....

9

4.6

Finishing the outdoor unit installation ........................................

9

4.6.1

To finish the outdoor unit installation ..........................

9

4.6.2

To check the insulation resistance of the compressor

10

5 Commissioning

10

5.1

Checklist before commissioning ................................................

10

5.2

To perform a test run .................................................................

10

5.3

Error codes when performing a test run ....................................

10

6 Technical data

12

6.1

Service space: Outdoor unit ......................................................

12

6.2

Piping diagram: Outdoor unit.....................................................

12

6.3

Wiring diagram: Outdoor unit ....................................................

13

1

About the documentation

1.1

About this document

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry  and  on  farms,  or  for
commercial use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Outdoor unit

2.1.1

To remove the accessories from the
outdoor unit

2

1

a

b

c

d

e

ENERG

IJA

Y

IA

IE

ENERG

IJA

Y

IA

IE

a

General safety precautions

b

Outdoor unit installation manual

c

Cable tie

d

Fluorinated greenhouse gases label

e

Energy label

3

Preparation

3.1

Preparing installation site

3.1.1

Installation site requirements of the
outdoor unit

Mind the spacing guidelines. See the "Technical data" chapter, and
the figures on the inside of the front cover.

INFORMATION

The sound pressure level is less than 70 dBA.

The  outdoor  unit  is  designed  for  outdoor  installation  only,  and  for
ambient temperatures ranging:

Summary of Contents for AZQS100B7Y1B

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners AZQS100B8V1B AZQS125B8V1B AZQS140B8V1B AZQS100B7Y1B AZQS125B7Y1B AZQS140B7Y1B ...

Page 2: ... 500 HU HD HU 200 1000 1000 500 HD HU HU a b 100 100 c d e eB eD A B C D E HB HD A B C 200 300 1000 A B C E 200 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 HD HU 250 1500 HU HD HU 300 1500 B D E HB HD HB HU 300 1000 1000 500 HU HB HU 300 1250 1000 500 HB HU HB HD HD HU 250 1500 1000 500 HU HD HU 300 1500 1000 500 HD HU 1 b mm HB HU b 250 HU HB HU b 300 HB HU HB HU 1000 200 2000 1...

Page 3: ...i navodili on vastavuses järgmis t e standardi te ga või teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele съответстват на следните стандарти или други нормативни документи при условие че се използват съгласно нашите инструкции atitinka žemiau nurodytus standartus ir arba kitus norminius dokumentus su sąlyga kad yra naudojami pagal mūsų nurodymus tad ja lietoti atb...

Page 4: ... unit 12 6 2 Piping diagram Outdoor unit 12 6 3 Wiring diagram Outdoor unit 13 1 About the documentation 1 1 About this document Target audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay persons Documentation set This document is part of a documentation set The complete set...

Page 5: ... rust easily a 4 1 2 To install the outdoor unit 4 M12 4 1 3 To provide drainage Make sure that condensation water can be evacuated properly INFORMATION If necessary you can use a drain plug kit field supply to prevent drain water from dripping NOTICE If drain holes of the outdoor unit are covered by a mounting base or by floor surface raise the unit to provide a free space of more than 150 mm und...

Page 6: ...e downwards piping route Drill a 4 and remove the knockout hole b Cut out the slits c with a metal saw c c b a 4 Ø6 mm 4 Do the following Connect the liquid pipe a to the liquid stop valve Connect the gas pipe b to the gas stop valve a b 5 Do the following Insulate the liquid piping a and the gas piping b Wind heat insulation around the curves and then cover it with vinyl tape c Make sure the fiel...

Page 7: ... 1 Charge the system with nitrogen gas up to a gauge pressure of at least 200 kPa 2 bar It is recommended to pressurize to 3000 kPa 30 bar in order to detect small leaks 2 Check for leaks by applying the bubble test solution to all connections 3 Discharge all nitrogen gas 4 3 3 To perform vacuum drying 1 Vacuum the system until the pressure on the manifold indicates 0 1 MPa 1 bar 2 Leave as is for...

Page 8: ...ula to calculate the greenhouse gas emissions GWP value of the refrigerant Total refrigerant charge in kg 1000 2 Fix the label on the inside of the outdoor unit There is a dedicated place for it on the wiring diagram label 4 5 Connecting the electrical wiring DANGER RISK OF ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables CAUTION For use of units in applications with temper...

Page 9: ...e a b V1 Y1 c c c c d d e e f f a Switch box b Stop valve attachment plate c Earth d Cable tie e Interconnection cable f Power supply cable 3 Fix the cables power supply and interconnection cable with a cable tie to the stop valve attachment plate 4 Route the wiring through the frame and connect it to it Routing through the frame Choose one of the 3 possibilities a b a b a b 2 3 1 a Power supply c...

Page 10: ...ed according to this document and have not been bypassed The power supply voltage matches the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box The insulation resistance of the compressor is OK There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks...

Page 11: ...tch two of the three electrical wires U4 or UF The inter unit branch wiring is not correct UA The outdoor and indoor unit are incompatible NOTICE The reversed phase protection detector of this product only functions when the product starts up Consequently reversed phase detection is not performed during normal operation of the product The reversed phase protection detector is designed to stop the ...

Page 12: ...d air from flowing back to the suction side through the bottom of the unit 2 Maximum two units can be installed Not allowed Multiple rows of units See figure 2 on the inside of the front cover Stacked units max 2 levels See figure 3 on the inside of the front cover A1 A2 A1 If there is danger of drainage dripping and freezing between the upper and lower units A2 Then install a roof between the upp...

Page 13: ... F1U F8U AZQS100_V1 F1U F2U Fuse F6U Fuse T 3 15 A 250 V F7U F8U Fuse F 1 0 A 250 V F1U F8U AZQS125 140_V1 F1U F4U Fuse F6U Fuse T 5 0 A 250 V F7U F8U Fuse F 1 0 A 250 V F1U F8U AZQS_Y1 F1U F2U Fuse 31 5 A 250 V F1U A2P Fuse T 5 0 A 250 V F3U F6U Fuse T 6 3 A 250 V F7U F8U Fuse F 1 0 A 250 V H1P H7P Light emitting diode service monitor is orange HAP Light emitting diode service monitor is green K1...

Page 14: ...chnical data Installation manual 14 AZQS100 140B8V1B AZQS100 140B7Y1B Split system air conditioners 4P385528 1C 2016 10 Colours BLK Black BLU Blue BRN Brown GRN Green ORG Orange RED Red WHT White YLW Yellow ...

Page 15: ......

Page 16: ...4P385528 1 C 00000003 4P385528 1C 2016 10 Copyright 2014 Daikin ...

Reviews: