12 AIR FLOW DATA & WIRING DIAGRAMS

AWSF 18-36

AWST 18-36

LARGE CHASSIS SMALL CHASSIS

2.5 & 3.0 TON 1.5 & 2.0 TON

A

36

36

B

24

20  3/16

C

21

16 1/8

D

19 7/8

16

E

15 7/8

11

CABINET DIMENSIONS

FIGURE 2

NOTE: SPECIFICATIONS & PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.

AWSF/AWST 18, 24, 30, 36

Thermostat 

Air Handler 

Condensing Unit 

#18 Gauge 

24 VAC 

#18 Gauge 

24 VAC 

Note: 

Connect T2, T3, or T4 to the Y

 

terminal to the outdoor unit. See Table 5

for correct CFM selec�on.

T1

 

T5

Figure 3 

NOTE: Connect appropriate speed tap (Pink/Purple/Yel-

low) to Y. Refer to Table 2 & 3 for speed tap selection.

Model

TAP

COLOR

T1

GREEN

T2

PURPLE

T3

PINK

T4

*

T5

WHITE

AWSF18SU16**

AWST18SU14**

AWSF24SU16**

AWST24SU14**

Table 2 

*NOTE: For units using 3KW and 5KW heaters, White 

wire will be connected to terminal 4.

Model

TAP

COLOR

T1

GREEN

T2

PURPLE

T3

PINK

T4

YELLOW

T5

WHITE

AWSF30LU16**

AWST30LU14**

AWSF36LU16**

AWST36LU14**

Table 3 

Summary of Contents for AWSF18SU16 Series

Page 1: ...R PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES IF YOU SERVICE THIS UNIT YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT IN ADDITION IN JURISDICTIONS...

Page 2: ...SERIOUS PROPERTY DAMAGE OR PERSONAL INJURY REDUCED UNIT PERFORMANCE AND OR HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF DEVICES THAT HAVE NOT BEEN APPROVED OR CERTIFIED BY THE MANUFACTURER CONTENTS...

Page 3: ...of carbon monoxide CO poisoning resulting from the exhaust emissions If a furnace or air handler is installed in an enclosed area such as a garage utility room or parking area and a carbon monoxide p...

Page 4: ...g guidelines If possible allow adequate length of tubing such that the coil may be removed for inspection or cleaning services from the cabinet without disconnecting the tubing Note These air handlers...

Page 5: ...ADIAN ELECTRIC CODE CSA C22 1 FAILURE TO OBSERVE THIS WARNING CAN RESULT IN ELECTRICAL SHOCK THAT CAN CAUSE PERSONAL INJURY OR DEATH WARNING 7 1 Building Electrical Service Inspection This unit is des...

Page 6: ...ped with the unit When these requirements are satisfied the unit achieves the following airflow leakage when tested in accordance with ASHRAE Standard 193 Cabinet air leakage less than 2 at 1 0 inch H...

Page 7: ...ction line Ensure the thermometer makes adequate contact and is insulated for best possible readings Use liquid line temperature to determine subcooling and vapor temperature to determine superheat 3...

Page 8: ...24 VAC 18 Gauge 24 VAC Y R G W C Y Y Note Connect T2 T3 or T4 to the Y terminal to the outdoor unit See Table 5 for correct CFM selec on T1 T5 Figure 3 NOTE Connect appropriate speed tap Pink Purple Y...

Page 9: ...3 Equalizer Must be connected to the 1 4 SAE connection on the suction line 4 Charge Ensure the system is properly charged There MUST be a minimum of 10 F Sub Cooled liquid at the valve inlet If the...

Page 10: ...ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT M ULTIPLE POWER SOURCES MAY BE PRESENT F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change Always refer...

Page 11: ...ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT M ULTIPLE POWER SOURCES MAY BE PRESENT F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change Always refer...

Page 12: ...ING THIS UNIT M ULTIPLE POWER SOURCES MAY BE PRESENT F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH WIRING DIAGRAM AWSF30LU16 AWST30LU14 Wiring is subject to change Always refer...

Page 13: ...ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT M ULTIPLE POWER SOURCES MAY BE PRESENT F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change Always refer...

Page 14: ...he unit without first discussing your plans with your dealer or other qualified servicer Restricted airflow could lead to poor operation and or severe equipment damage Likewise it is important to keep...

Page 15: ...WB F DB F WB F Heating Supply Air Temperature DB F Temperature Rise DB F Delta T Difference between Supply and Return Temperatures DB F AirHandler Coil InverterMatched INVERTERAH COILONLY Check EEV an...

Page 16: ...page DAIKIN AMANA BRAND GOODMAN BRAND DAIKIN AMANA BRAND GOODMAN BRAND PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty regist...

Reviews: