SiBE04-824
Indoor Unit
Removal Procedure
161
1.8
Removal of
Fan Motor
Procedure
Warning
Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step
Procedure
Points
1
Undo the fan motor
lead wires from the
hooks.
Preparation
Remove the drain pan unit
according to the “Removal
of Drain Pan Unit.”
You can remove the fan
motor with the heat
exchanger left.
It is easy to clean up the
heat exchanger.
2
Loosen and remove the
fan rotor lock screw.
3
Remove the 2 screws
of the fan motor fixing
plate.