![background image](http://html.mh-extra.com/html/daikin/atxg25ev1b/atxg25ev1b_installation-manual_501393010.webp)
■
English
8
6) Wrap the insulation on the piping with insulating tape. If you are not replacing the drain hose, store it in the location shown below.
NOTE:
1. When fixing the indoor unit screws, use an Indoor unit fixing
screw (M4 × 12L). (In one place on the left side or the right side.)
7) Store any excess power cord behind the indoor unit. (See
4-1.
6))
8) Making sure not to pinch the interunit wiring and the power cord, push
on the bottom of the indoor unit with both hands and attach the tabs.
If the indoor unit won’t attach to the mounting plate, fix the bottom
panel to the mounting plate with screws.
(In one place on the left side or the right side.)
5.
Wiring
1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the
corresponding terminals.
3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) Shape the wires so that the service lid fits securely, then close service lid.
WARNING
1) Do not use tapped wires, stand wires, extensioncords, or starbust connections, as they may cause overtheating, electrical
shock,or fire
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the
terminal block.) Doing so may cause electric shock or fire.
Drain hose
F M4
×
12L
F
1
2
3
Terminal block
Wiring clamp
Electric parts box
Terminal block
Electric parts box
Wire retainer
Use the specified wire type.
Shape wires so that the
service lid will fit securely.
Secure firmly so that no
external pressure is directly
applied too the terminals.
Use the indicated
wiring and
connect securely.
Firmly secure wire retainer so that
wires sustain no external stress.
1
2
3
1 2 3
L N
Safety
breaker
15A
Earth leakage
circuit breaker
Earth
When wire length exceeds
10m, use 2.0mm wires.
H05VV
Firmly fix the wires with
the terminal screws.
Outdoor unit
Indoor
unit
Power
supply
50Hz 220-240V
Firmly fix the wires with
the terminal screws.
15mm
12mm
15mm
22mm
Strip dimension (actual size)
After shaping
01_EN_3P166464-1.fm Page 8 Saturday, September 17, 2005 11:08 AM