background image

English

8

3-2. Left-side, left-back, or left-bottom piping.

1) Attach the drain hose to the underside of the refrigerant pipes 

with adhesive vinyl tape.

2) Be sure to connect the drain hose to the drain port in place of a 

drain plug.

3) Shape the refrigerant pipe along 

the pipe path marking on the 
mounting plate.

4) Pass drain hose and refrigerant 

pipes through the wall hole, then 
set the indoor unit on mounting 
plate hooks, using the 

 mark-

ings at the top of indoor unit as a 
guide.

5) Pull in the interconnecting wires.
6) Connect the inter-unit piping.

7) Wrap the refrigerant pipes and 

drain hose together with insulation tape as right figure, in case of setting 
the drain hose through the back of the indoor unit.

8) While exercising care so that the interconnecting wires do not catch indoor 

unit, press the bottom edge of indoor unit with both hands until it is firmly 
caught by the mounting plate hooks.  Secure indoor unit to the mounting 
plate with screws (M4 × 12L).

3-3. Wall embedded piping.

Follow the instructions given under. 

1) Insert the drain hose to this depth so it won’t be pulled out of the drain 

pipe.

Left-side, left-back, or left-bottom piping

           

 

  

   

 

    

 


 

How to set drain plug.

No gap.

Do not apply lubricating

oil (refrigerant machine

oil) when inserting.

Application of causes

deterioration and drain

leakage of the plug.

Insert a hexagon wrench (4mm).

Wrap insulating tape around the bent portion

of refrigerant pipe.

Overlap at least half the width of the tape

with each turn.

Drain

hose

Caulk this hole

with putty or

caulking material.

Bind with plastic

tape.

A Mounting plate

 

 

 

 

×

   

 

Inner wall

Vinyl chloride

drain pipe

(VP-30)

Drain hose

50mm

or more

Insert drain hose

to this depth so

it won’t be pulled

out of drain pipe.

Outer wall

01_EN_3P212421-1.fm  Page 8  Wednesday, September 26, 2007  5:57 PM

Summary of Contents for ATKS20E2V1B

Page 1: ...Italiano ΕλληνικÜ Portugues Installation manual R410A Split series Installationsanleitung Split Baureihe R410A Manuel d installation Série split R410A Montagehandleiding R410A Split systeem Manual de instalación Serie Split R410A Manuale d installazione Serie Multiambienti R410A Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A Manual de Instalação Série split R410A 00_CV_3P212421 1 fm Page 1 Frid...

Page 2: ...36 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 K...

Page 3: ...lamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out during the installation work ventilate the room The r...

Page 4: ...om electronic ignition type fluorescent lamps inverter or rapid start type as they may shorten the remote control range 8 the unit is at least 1 metre away from any television or radio set unit may cause interference with the picture or sound 9 install at the recommended height 1 8m 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site where remote c...

Page 5: ...lter 2 Remove the front grille 3 In front of the mark of the front grille there are 3 upper hooks Lightly pull the front grille toward you with one hand and push down on the hooks with the fingers of your other hand When there is no work space because the unit is close to ceiling CAUTION Be sure to wear protection gloves Place both hands under the center of the front grille and while pushing up pu...

Page 6: ... con trollers can be set for different addresses 1 In the same way as when connecting to an HA system remove the metal plate electrical wiring cover 2 Cut the address jumper JA on the printed circuit board 3 Cut the address jumper J4 in the remote controller 01_EN_3P212421 1 fm Page 4 Wednesday September 26 2007 5 57 PM ...

Page 7: ...e finishing tape from bottom to top Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line Caulk pipe hole gap with putty Mounting plate Clip Mark rear side Bottom frame Front grille How to attach the indoor unit Hook the claws of the bottom frame to the mounting plate If the claws are difficult to hook remove th...

Page 8: ...and Dimensions 80 100 400 135 450 283 47 5 141 5 50 5 46 5 44 5 131 5 87 44 5 110 60 130 220 50 60 110 800 φ65 φ65 Use tape measure as shown Position the end of a tape measure at Keep here the piece cut out from the unit for piping Liquid pipe end Gas pipe end The removed pipe port cover can be kept in the mounting plate pocket Removed pipe port cover A Mounting plate Through the wall hole φ65mm D...

Page 9: ...se and refrigerant pipes through the wall hole then set the indoor unit on the mounting plate hooks by using the markings at the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to Installation tips 5 Pass the interconnecting wires from the outdoor unit through the feed through wall hole and then through the back of the indoor unit Pull them through the fron...

Page 10: ...catch indoor unit press the bottom edge of indoor unit with both hands until it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with screws M4 12L 3 3 Wall embedded piping Follow the instructions given under 1 Insert the drain hose to this depth so it won t be pulled out of the drain pipe Left side left back or left bottom piping How to set drain plug No gap D...

Page 11: ...ords or starburst connections as they may cause overheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire 5 When connecting to an HA system 1 Remove the front grille 2 screws 2 Remove the electrical wiring box 1 screw 3 Remove the metal plat...

Page 12: ... pipe 5 Check that the flaring is properly made WARNING 1 Do not use mineral oil on flared part 2 Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with the unit 4 Do never install a drier to this R410A unit in order to guarantee its lifetime 5 The dryi...

Page 13: ...Refrigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimen sions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation 20 25 35 cla...

Page 14: ...s turned off 1 3 Carry out the test operation in accordance with the Operation Manual to ensure that all functions and parts such as louver movement are working properly The air conditioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit break...

Page 15: ... 0710 HT 3P212421 1 M07B075 Two dimensional bar code is a code for manufacturing 00_CV_3P212421 1 fm Page 2 Friday July 20 2007 2 31 PM ...

Reviews: