Wiring diagram

Wiring diagram parts table

:

Terminal strip

:

Field wiring

:

Connector

:

Relay connector

:

Connection

:

Terminal

BLK

:

Black

ORG

:

Orange

BLU

:

Blue

RED

:

Red

BRN

:

Brown

WHT

:

White

GRN

:

Green

YLW

:

Yellow

Notes

:

Refer to the nameplate of the unit for power requirements.

:

TO INDOOR UNIT

To indoor unit

:

POWER SUPPLY

Power supply

:

IN CASE OF COOLING ONLY TYPE

In case of cooling only type

:

OUTDOOR

Outdoor

:

CONDENSER

Condenser

:

DISCHARGE

Discharge

C7,C8..................... Capacitor
DB1,DB3................ Diode bridge
FU1,FU2,FU3 ........ Fuse
FU4 ........................ Field fuse
IPM ........................ Intelligent power module
L............................. Live
L803,L804.............. Reactor
M1C ....................... Compressor motor
M1F........................ Fan motor
MRCW,MRM10,
MRM20,MR30........ Magnetic relay
N ............................ Neutral
Q1L ........................ Overload protector
Q1DI ...................... Earth leak detector

PCB1,PCB2 ...........Printed circuit board
S10,S11,S12,S20,
S40,S70,S80,S90,
HL3,HN3,X11A.......Connector
R1T,R2T,R3T .........Thermistor
SA1 ........................Surge absorber
V1,V2,V3................Varistor
X1M........................Terminal strip
Y1E ........................Electronic expansion valve coil
Y1S ........................Reversing solenoid valve
Z1C~Z4C ...............Noise filter (ferrite core)

........................Protective earth
........................Earth

Summary of Contents for ARXS35L2V1B

Page 1: ...ion S rie split R410A Fran ais Montagehandleiding R410A Split systeem Nederlands Manual de instalaci n Serie Split R410A Espa ol Manuale d installazione Serie Multiambienti R410A Italiano R410A Manual...

Page 2: ...es valorado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o pare...

Page 3: ...ce en A y es valorado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e...

Page 4: ...rmal heat build up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper...

Page 5: ...om ceiling or stacked CAUTION When operating the air conditioner in a low outdoor ambient temperature be sure to follow the instructions described below To prevent exposure to wind install the outdoor...

Page 6: ...the stop valve cover Remove the screw on the stop valve cover Slide the lid downward to remove it How to attach the stop valve cover Insert the upper part of the stop valve cover into the outdoor uni...

Page 7: ...e foundation surface Outdoor Unit Installation 1 Installing outdoor unit 1 When installing the outdoor unit refer to Precautions for Selecting the Location and the Outdoor Unit Installation Drawings 2...

Page 8: ...rque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them full...

Page 9: ...x Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insula...

Page 10: ...f charging hose which comes from gauge manifold to gas stop valve s service port 2 Fully open gauge manifold s low pressure valve Lo and completely close its high pressure valve Hi High pressure valve...

Page 11: ...3 Disconnect the selective connector for standby electricity saving 4 Turn on the main power supply CAUTION Before connecting or disconnecting the selective connector for standby electricity saving ma...

Page 12: ...n pressing the switch do not touch the terminal block It has a high voltage so doing so may cause electric shock After closing the liquid stop valve close the gas stop valve within 3 minutes then stop...

Page 13: ...block Observe the notes mentioned below when wiring to the power supply terminal block Precautions to be taken for power supply wiring CAUTION When connecting the connection wires to the terminal blo...

Page 14: ...R Outdoor CONDENSER Condenser DISCHARGE Discharge C7 C8 Capacitor DB1 DB3 Diode bridge FU1 FU2 FU3 Fuse FU4 Field fuse IPM Intelligent power module L Live L803 L804 Reactor M1C Compressor motor M1F Fa...

Page 15: ...a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit brea...

Page 16: ...3P360062 2C 2013 11 Copyright 2013 Daikin...

Reviews: