6 Disposal
Installation manual
13
(A)RXP20~3 RXF20~3 RXF20~25B5V1B
R32 split series
3P519299-2H – 2019.09
c
b
e
d
d
a
a
Gas stop valve
b
Closing direction
c
Hexagonal wrench
d
Valve cap
e
Liquid stop valve
6.3
To start and stop forced cooling
There are 2 methods to perform forced cooling.
▪
Method 1.
Using the indoor unit ON/OFF switch (if present on the
indoor unit).
▪
Method 2.
Using the indoor unit user interface.
6.3.1
To start/stop forced cooling using the
indoor unit ON/OFF switch
1
Press the ON/OFF switch for at least 5 seconds.
Result:
Operation will start.
INFORMATION
Forced cooling stops automatically after 15 minutes.
2
To stop operation sooner, press the ON/OFF switch.
6.3.2
To start/stop forced cooling using the
indoor unit user interface
1
Set the operation mode to
cooling
.
For the procedure, refer to "To perform a test run" in the installation
manual of the indoor unit.