![background image](http://html1.mh-extra.com/html/daikin/arxg35e3v1b/arxg35e3v1b_service-manual_4183465050.webp)
SiBE04-809
Control Specification
Function and Control
39
Frequency
Compressor
Four way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0Hz
5sec.
350pulse
450pulse
450pulse
Initial opening
PI control
5sec.
50sec.
50sec.
660sec.
60sec.
76Hz
86Hz
30Hz
(R8329)
60sec.
Outdoor temp.
<
0˚C
Outdoor temp.
≥
0˚C