![background image](http://html.mh-extra.com/html/daikin/arxg25cvmb/arxg25cvmb_service-manual_501318135.webp)
Indoor Unit
Si04-402A
126
Removal Procedure
1.6
Removal of Reduction Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the front grille.
1. Remove the assembly of
reduction motor.
1
Loosen the screw.
2
Release the 2 hooks
and remove the
assembly.