Wiring Diagrams
SiBE04-401
214
Appendix
2.2
Outdoor Units
RK(X)S 20/25/35 CVMB, ARK(X)S 20/25/35 CVMB
RKH20/25/35CVMB9, ARKH20/25/35CVMB9, RN20/25/35CVMB9
NOTE
N
MRCW, MRM10, MRM20 : MAGNETIC RELAY
L
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
indoor
L
: LIVE
IPM1
: INTELLIGENT POWER MODULE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
C74, C75
IC11
: TRIAC
DB1, DB2
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
C94, C95, C100
: CAPACITOR
3
2
1
FIELD WIRING.
L
N
X1M
2
3
1
RED
BLK
WHT
GRN/YL
W
Z2C
GRN/YL
W
HN1
HL1
E
S
FU3
20A
V2
PCB1
V3
N
: NEUTRAL
SA1
Q1L
: OVERLOAD PROTECTOR
PCB1, PCB2
: PRINTED CIRCUIT BOARD
R1T, R2T, R3T
: THERMISTOR
S30, S40, S70
HC3, HC4, HL3, HN3 : CONNECTOR
S80, S90, S91
S10, S11, S20
L1
outdoor
S80
TYPE
COOLING ONLY
IN CASE OF
HC2
1
C100
MRM10
MRM20
7
1
HC1
3
S11
WHT
BLK
BLK
BLK
BLK
BLK
BLK
HR1
HN2
HL2
ORG
GRY
BLU
1
7
1
ORG
S10
RED
S20
M
YL
W
BLK
L1R
Y1E
GR
Y
6
SA1
: SURGE ARRESTER
V1, V2, V3
: VARISTOR
Y1E
: ELECTRONIC EXPANSION VALVE COIL
Y1R
: REVERSING SOLENOIDE VALVE COIL
X1M
: TERMINAL STRIP
Z1C, Z2C
: FERRITE CORE
WHT
3.15A
MRCW
S80
HL3
FU1
HN3
TYPE
HEAT PUMP
IN CASE OF
YLW
BRN
ORG
1
Y1R
V1
: PROTECTIVE EARTH
HR2
3
(OUTDOOR)
~
~
DB1
IC11
+
-
PCB2
R1T
1
(CONDENSER)
BLK
t˚
BLK
S90
HC3
R2T
~
~
BLK
DB2
t˚
+
-
BLK
(DISCHARGE)
R3T
BLK
6
t˚
BLK
S70
C75
C74
1
HC4
WHT
2
ORG
1
+
-
-
+
3
M
~
BRN
4
M1F
BLU
+
-
+
-
C94
3.15A
7
FU2
RED
C95
2
Q1L
S40
BLK
GR
Y
1
S30
3D042576C
W
+
W
-
5
BLU
M1C
IPM1
V
V
3
YL
W
U
1
U
N=2
Z1C
RED
NOTE
N
L
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
FIELD WIRING.
indoor
L
: LIVE
PCB
: PRINTED CIRCUIT BOARD
X1M
: TERMINAL STRIP
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
DB1, DB2
: DIODE BRIDGE
FU1, FU3
: FUSE
C74, C75, C80
C94, C95, C100 : CAPACITOR
2
3
1
X1M
L
3
N
2
1
RED
BLK
WHT
GRN/YL
W
GRN/YL
W
HN1
HL1
E
S
FU3
20A
N
: NEUTRAL
MRCW, MRL
Q1L
: OVERLOAD PROTECTOR
SA1
: SURGE ARRESTER
MRM10, MRM20
: MAGNETIC RELAY
R1T, R2T, R3T
: THERMISTOR
S20, S70, S80, S90 : CONNECTOR
V2
V3
SA1
L1
outdoor
S70
Z2C
PCB
M1F
1
BLK
MRL
1
3
M
~
WHT
C80
6
3.15A
RED
MRCW
FU1
3
V1
1
MRM10
S80
MRM20
(OUTDOOR)
L1R
Z3C
HR1
Y1E
: ELECTRONIC EXPANSION VALVE COIL
V1, V2, V3
: VARISTOR
IPM1
: INTELLIGENT POWER MODULE
IC11
: TRIAC
Z1C, Z2C, Z3C : FERRITE CORE
: PROTECTIVE EARTH
R1T
1
(CONDENSER)
BLK
BRN
t˚
BLK
R2T
BLK
t˚
BLK
HR2
(DISCHARGE)
ORG
R3T
BLK
6
t˚
BLK
S90
IC11
~
~
DB1
+
-
1
ORG RED
Y1E
M
YL
W
BLK GR
Y
6
~
~
DB2
WHT
+
-
S20
X30A
C100
OL2
6
Q1L
C75
C74
+
-
-
+
BLK
BLK
OL1
GR
Y
GR
Y
-
+
+
-
C94
C95
Z1C
3D042577A
+
W
BLU
-
W
W
IPM1
BLU
V
M1C
V
V
YL
W
YL
W
U
U
N=5
U
RED
1
RED
Summary of Contents for ARKH20CVMB9
Page 67: ...Control Specification SiBE04 401 58 Function and Control ...
Page 97: ...Instruction SiBE04 401 88 System Configuration ...
Page 141: ...Check SiBE04 401 132 Service Diagnosis ...
Page 211: ...Outdoor Unit RK X H C ARK X H C R Y N C SiBE04 401 202 Removal Procedure ...
Page 215: ...Others SiBE04 401 206 Others ...