9
|
Troubleshooting
User reference guide
54
EHYH EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
Possible cause
Corrective action
The desired room temperature cannot
be reached.
Increase the desired leaving water
temperature in accordance with the
heat emitter type. See
thermostat control - Using the leaving
water temperature home pages"
22].
The weather-dependent curve is set
incorrectly.
Adjust the weather-dependent curve.
See
9.5 Symptom: The water at the tap is too cold
Possible cause
Corrective action
Your tank ran out of domestic hot water
because of unusual high consumption.
If you immediately need domestic hot
water, activate the DHW tank booster
mode. However, this consumes extra
energy. See
30].
If you can wait, overrule (increase) the
active or next scheduled desired
temperature so that more hot water
will be produced exceptionally. See
29].
If the problems recurs daily, do one of
the following:
▪
Increase the DHW tank temperature
preset value. See
38].
▪
Adjust the DHW tank temperature
schedule.
Example:
Program to
additionally heat up the DHW tank to
a preset value (
Storage eco
=
lower tank temperature) during the
day.
See
39] and
The desired DHW tank temperature is
too low.
The instant DHW temperature is too
low. (Only applicable when no tank is
installed).
Increase the instant DHW set point
temperature. See
27].
9.6 Symptom: Heat pump failure
When the heat pump fails to operate, the gas boiler can serve as an emergency
back-up heater and either automatically or non-automatically take over the entire
heat load.