6
|
Energy visualisation
User reference guide
50
EHYH EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
6 Energy visualisation
The user interface is able to graphically display energy statistics for:
▪
produced energy: energy produced by the heat pump.
▪
consumed electricity: recorded by an electricity meter or, when none is installed,
calculated by the interface itself based on an internal calculation.
▪
consumed gas: only recorded when an external gas meter is installed. Note that
the values recorded by the meter may differ from those shown on the boiler.
6.1 To view the energy statistics
Prerequisite:
You switched the permission level to Advanced end user.
1
Go to [6.2]: >
Information
>
Energy metering
.
2
Select either
Consumed elec.
,
Produced energy
or
Consumed gas
.
3
Use the and buttons to toggle between views of the current month, the
previous month, the last 12 months and a general overview.
4
Use the and buttons to toggle between different modes (if applicable).