4
|
Operation
User reference guide
23
EHYH EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
To adjust/overrule the leaving water temperature (NOT linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature
setpoint, see
"4.4.3 Determining which temperature control you are using"
16].
To adjust the leaving water temperature (main)
1
Go to the main leaving water temperature home page (
LWT main
).
2
Press or to adjust.
Example:
35°C 37°C
INFORMATION
In case of weather dependency, an offset value can be modified.
To adjust the leaving water temperature (additional)
1
Go to the additional leaving water temperature home page (
LWT add
).
2
Press or to adjust.
Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
To adjust/overrule the leaving water temperature (linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature
setpoint, see
"4.4.3 Determining which temperature control you are using"
16].
To set leaving water temperature preset values (main)
INFORMATION
You cannot adjust/overrule the leaving water temperature (main) for room
thermostat control with linked leaving water temperatures. However if necessary,
you can adjust the desired leaving water temperature (main) by adjusting preset
values.
INFORMATION
Adjusting the leaving water temperature is permanent unless the leaving water
temperature is according to a schedule. In that case the overruling is valid until the
next scheduled action.
1
Go to [7.4.2]: >
User settings
>
Preset values
>
LWT main
.
2
Set the
Preset values
according to following graph.
Example:
Room thermostat comfort temperature will correspond with leaving
water comfort temperature.