background image

4 Operation

User reference guide

7

EHBH/X04+08DA + EHVH/X04+08S18+23DA
Daikin Altherma – Low temperature split
4P495250-1 – 2017.12

4.4

Space heating/cooling control

4.4.1

About space heating/cooling control

Controlling  space  heating/cooling  typically  consists  of  the  following
stages:

1

Setting the space operation mode

2

Controlling the temperature

Depending on the system layout and installer configuration, you use
a different temperature control:

▪ Room  thermostat  control  (linked  or  NOT  linked  to  leaving  water

temperature)

▪ Leaving water temperature control

▪ External room thermostat control

4.4.2

Setting the space operation mode

About space operation modes

Depending  on  your  heat  pump  model,  you  have  to  tell  the  system
which space operation mode to use: heating or cooling.

If a … heat pump

model is installed

Then…

Heating/cooling

The system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.

Heating only

The system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.

To determine if a heating/cooling heat pump model is installed

1

Go to [4]: Space heating/cooling.

2

Check if [4.1] Operation mode is listed and editable.
If so, a heating/cooling heat pump model is installed.

To tell the system which space operation to use, you can:

You can…

Location

Check

 which space operation mode is

currently used

.

Home screen

Set

 the space operation 

mode 

permanently. Main menu

Restrict

 

automatic changeover

 according

to a monthly schedule.

To check which space operation mode is currently used

The space operation mode is displayed on the home screen:

▪ When the unit is in heating mode, the 

 icon is shown.

▪ When the unit is in cooling mode, the 

 icon is shown.

The status indicator shows if the unit is currently in operation:

▪ When the unit is not in operation, the status indicator will show a

blue pulsation with an interval of approximately 5 seconds.

▪ While the unit is in operation, the status indicator will light up blue

constantly.

To set the space operation mode

1

Go to [4.1]: Space heating/cooling > Operation mode

2

Select one of the following options:

▪ Heating: Always heating mode

▪ Cooling: Always cooling mode

▪ Automatic: 

The 

operation 

mode 

changes

automatically  based  on  the  outdoor  temperature.
Restricted  according  to  the  operation  mode
schedule.

Automatic  heating/cooling  changeover  is  is  NOT  applicable  for
heating  only  models.  When  Automatic  is  selected,  the  changing  of
the operation mode is based on the Operation mode schedule [4.2].

To restrict automatic changeover according to a schedule

Conditions: 

You set the space operation mode to Automatic.

1

Go to [4.2]: Space heating/cooling > Operation mode
schedule.

2

Select a month.

3

For each month, select an option:

▪ Reversible: Not restricted

▪ Heating only: Restricted

▪ Cooling only: Restricted

4

Confirm the changes.

Example: Changeover restrictions

When

Restriction

During cold season.

Example: 

October, November,

December, January, February and March.

Heating only

During warm season.

Example: 

June, July and August.

Cooling only

In-between.

Example: 

April, May and September.

Heating/Cooling

If  both  the  Operation  mode  and  the  Operation  mode  schedule  are
set  to  Automatic,  the  operation  mode  will  be  determined  by  the
outdoor temperature.

4.4.3

Determining which temperature control
you are using

To determine which temperature control you are
using (method 1)

Check the installer settings table filled in by the installer.

To determine which temperature control you are
using (method 2)

You can see on the home screen which temperature control you are
using.

6

1.6

bar

18 Feb 2018

22:19

55

18
21
45

a2

a1

b

a1

Heat emitter of the main zone

a2

Heat emitter of the additional zone (if any)

b

Room thermostat type of the main zone

To determine the number of temperature zones

Check the number of heat emitters displayed on the home screen:

If…

Then…

One heat emitter symbol is displayed

There is only one zone.

Summary of Contents for Altherma EHBH04+08DA

Page 1: ...ikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHBH04 08DA EHBX04 08DA EHVH04S18DA EHVH04S23DA EHVH08S18DA EHVH08S23DA EHVX04S18DA EHVX04S23DA E...

Page 2: ...e 16 6 2 To find the contact helpdesk number 17 7 Troubleshooting 17 7 1 To display the help text in case of a malfunction 17 7 2 To check the malfunction history 17 7 3 Symptom You are feeling too co...

Page 3: ...ng this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used...

Page 4: ...r more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens...

Page 5: ...t date and time Holiday f Holiday mode active Item Description Main zone g3 g1 g4 g2 g1 Heat emitter type Underfloor heating Fancoil unit Radiator g2 Leaving water temperature setpoint g3 Room thermos...

Page 6: ...ure limit a1 Fixed by the unit a2 Restricted by the installer Maximum temperature limit b1 Fixed by the unit b2 Restricted by the installer Current temperature c Measured by the unit Desired temperatu...

Page 7: ...icator will show a blue pulsation with an interval of approximately 5 seconds While the unit is in operation the status indicator will light up blue constantly To set the space operation mode 1 Go to...

Page 8: ...ion occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off leaving water temperature scheduling 1 Go to one of the following 2 1 Main zone Schedule 3 1 Additional z...

Page 9: ...nk heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1...

Page 10: ...capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following 1 Go to 7 4 1 User settings Quiet Activation 2 Select Most quiet Adva...

Page 11: ...elect the correct electricity price 3 Confirm the changes 4 Repeat this for all three electricity prices INFORMATION Price value ranging from 0 00 990 valuta kWh with 2 significant values INFORMATION...

Page 12: ...de on page 7 5 5 Tank Schedule Program the domestic hot water tank temperature for your normal domestic hot water needs Comfort Eco Stop 7 4 2 User settings Quiet Schedule Program when the unit has to...

Page 13: ...Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule INFORMATION Not all schedules can be...

Page 14: ...wer the tank temperature will need to be higher as the water pipes will be colder and vice versa The weather dependent curves are defined by two setpoints Setpoint X1 Y2 Setpoint X2 Y1 Weather depende...

Page 15: ...tings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electri...

Page 16: ...er desired leaving water temperature results in lower energy consumption and better performance In cooling the opposite is valid Set the desired leaving water temperature in accordance with the heat e...

Page 17: ...n The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Ad...

Page 18: ...t of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operate...

Page 19: ......

Page 20: ...4P495250 1 2017 12 Copyright 2017 Daikin...

Reviews: