5 Energy saving tips

User reference guide

16

EHBH/X04+08DA + EHVH/X04+08S18+23DA

Daikin Altherma – Low temperature split

4P495250-1 – 2017.12

4.10

Installer settings: Tables to be
filled in by installer

4.10.1

Configuration wizard

Setting

Fill in…

System

Indoor unit type (read only)

Backup heater type [9.3.1]

Domestic hot water [9.2.1]

Emergency [9.5]

Number of zones [4.4]

Backup heater

Voltage [9.3.2]

Configuration [9.3.3]

Capacity step 1 [9.3.4]

Additional capacity step 2 [9.3.5]
(if applicable)

Main zone

Emitter type [2.7]

Control [2.9]

Setpoint mode [2.4]

Schedule [2.1]

Additional zone (only if [4.4] = 1)

Emitter type [3.7]

Control (read only) [3.9]

Setpoint mode [3.4]

Schedule [3.1]

Tank

Heat up mode [5.6]

Comfort setpoint [5.2]

Eco setpoint [5.3]

Reheat setpoint [5.4]

4.10.2

Settings menu

Setting

Fill in…

Main zone

Thermostat type [2.A]

Additional zone (if applicable)

Thermostat type [3.A]

Information

Dealer information [8.3]

5

Energy saving tips

Tips about room temperature

▪ Make  sure  the  desired  room  temperature  is  NEVER  too  high  (in

heating  mode)  or  too  low  (in  cooling  mode),  but  ALWAYS
according  to  your  actual  needs.  Each  saved  degree  can  save  up
to 6% of heating/cooling costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  or  cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature  until  the  next  scheduled  action. 

Example: 

When

you have a party, or when you are leaving for a couple of hours.

▪ For longer periods: You can use the holiday mode.

Tips about leaving water temperature

▪ In  heating  mode,  a  lower  desired  leaving  water  temperature

results  in  lower  energy  consumption  and  better  performance.  In
cooling, the opposite is valid.

▪ Set the desired leaving water temperature in accordance with the

heat  emitter  type. 

Example: 

Underfloor  heating  is  designed  for

lower  leaving  water  temperature  than  radiators  and  heat  pump
convectors.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage

comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant  charge  in  the  system  (expressed  as  tonnes
CO

2

-equivalent)  is  used  to  determine  the  maintenance

intervals. Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

Summary of Contents for Altherma EHBH04+08DA

Page 1: ...ikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHBH04 08DA EHBX04 08DA EHVH04S18DA EHVH04S23DA EHVH08S18DA EHVH08S23DA EHVX04S18DA EHVX04S23DA E...

Page 2: ...e 16 6 2 To find the contact helpdesk number 17 7 Troubleshooting 17 7 1 To display the help text in case of a malfunction 17 7 2 To check the malfunction history 17 7 3 Symptom You are feeling too co...

Page 3: ...ng this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used...

Page 4: ...r more information LCD screen The LCD screen has a sleeping function After a certain time of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens...

Page 5: ...t date and time Holiday f Holiday mode active Item Description Main zone g3 g1 g4 g2 g1 Heat emitter type Underfloor heating Fancoil unit Radiator g2 Leaving water temperature setpoint g3 Room thermos...

Page 6: ...ure limit a1 Fixed by the unit a2 Restricted by the installer Maximum temperature limit b1 Fixed by the unit b2 Restricted by the installer Current temperature c Measured by the unit Desired temperatu...

Page 7: ...icator will show a blue pulsation with an interval of approximately 5 seconds While the unit is in operation the status indicator will light up blue constantly To set the space operation mode 1 Go to...

Page 8: ...ion occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off leaving water temperature scheduling 1 Go to one of the following 2 1 Main zone Schedule 3 1 Additional z...

Page 9: ...nk heats up until it reaches the reheat set point example 45 C This ensures that a minimum amount of hot water is available at all times Example t Tt 60 C 00 00 07 00 50 C 45 C 15 C 14 00 21 00 35 C 1...

Page 10: ...capacity of the system However during the afternoon the baby is sleeping and you want it to be quiet Then you can do the following 1 Go to 7 4 1 User settings Quiet Activation 2 Select Most quiet Adva...

Page 11: ...elect the correct electricity price 3 Confirm the changes 4 Repeat this for all three electricity prices INFORMATION Price value ranging from 0 00 990 valuta kWh with 2 significant values INFORMATION...

Page 12: ...de on page 7 5 5 Tank Schedule Program the domestic hot water tank temperature for your normal domestic hot water needs Comfort Eco Stop 7 4 2 User settings Quiet Schedule Program when the unit has to...

Page 13: ...Sat 4 Confirm the changes 5 Select Saturday 6 Select Copy 7 Select Sunday 8 Select Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C To rename the schedule INFORMATION Not all schedules can be...

Page 14: ...wer the tank temperature will need to be higher as the water pipes will be colder and vice versa The weather dependent curves are defined by two setpoints Setpoint X1 Y2 Setpoint X2 Y1 Weather depende...

Page 15: ...tings Language Time date Holiday Quiet Electricity price Gas price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electri...

Page 16: ...er desired leaving water temperature results in lower energy consumption and better performance In cooling the opposite is valid Set the desired leaving water temperature in accordance with the heat e...

Page 17: ...n The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase decrease the room temperature preset value Ad...

Page 18: ...t of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or operate...

Page 19: ......

Page 20: ...4P495250 1 2017 12 Copyright 2017 Daikin...

Reviews: