4 Operation
User reference guide
6
EHBH/X04+08DA + EHVH/X04+08S18+23DA
Daikin Altherma – Low temperature split
4P495250-1 – 2017.12
Item
Description
Additional zone
Restriction:
Only displayed if there are two
leaving water temperature zones. Shows
the applicable symbol for your additional
zone emitter type.
Set the leaving water temperature for the
additional zone (if present).
Space heating/
cooling
Shows the applicable symbol for your unit.
Put the unit in heating mode or cooling
mode. You cannot change the mode on
heating only models.
Tank
Restriction:
Only displayed if a domestic
hot water tank is present.
Set the domestic hot water tank
temperature.
User settings
Gives access to user settings such as
holiday mode and quiet mode.
Information
Displays data and information about the
indoor unit.
Installer settings
Restriction:
Only for the installer.
Gives access to advanced settings.
Commissioning
Restriction:
Only for the installer.
Perform tests and maintenance.
User profile
Change the active user profile.
Operation
Turn heating/cooling functionality and
domestic hot water preparation on or off.
4.2.3
Setpoint screen
The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Example:
▪ Room temperature screen
▪ Main zone screen
▪ Additional zone screen
▪ Tank temperature screen
a1
d
+
–
d
e
d
e
c
a2
b1
b2
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
Item
Description
Minimum temperature limit
a1
Fixed by the unit
a2
Restricted by the installer
Maximum temperature limit
b1
Fixed by the unit
b2
Restricted by the installer
Current temperature
c
Measured by the unit
Desired temperature
d
Turn the right dial to
increase/decrease.
Submenu
e
Turn or press the left dial to
go to the submenu.
4.2.4
Detailed screen with values
a
b
a
Settings
b
Values
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Confirm changes and proceed.
4.3
Basic usage
4.3.1
Using the home screen
About the home screen
On the home screen, you can read out the most important settings
that are meant for daily usage. The setup of the unit is displayed in a
schematic way. See
for more
information.
To go to the home screen
Press the button to return to the home screen.
4.3.2
Using the menu structure
About the menu structure
Go to the menu structure to change the settings of the unit and read
out values such as the current temperature. For an overview of the
settings available to the user, see
.
To go to the menu structure
Press
to go to the menu structure.
4.3.3
Turning operation ON or OFF
Certain functionalities of the unit can be enabled of disabled
separately. If a functionality is disabled, the corresponding
temperature icon in the home screen will be greyed out.
To turn room temperature control ON or OFF
1
Go to [C.1]: Operation > Room.
2
Set operation to On or Off.
To turn space heating/cooling operation ON or OFF
1
Go to [C.2]: Operation > Space heating/cooling.
2
Set operation to On or Off.
To turn tank heating operation ON or OFF
1
Go to [C.3]: Operation > Tank.
2
Set operation to On or Off.
Summary of Contents for Altherma EHBH04+08DA