![Daikin Altherma EBLQ011CAV3 User Reference Manual Download Page 8](http://html.mh-extra.com/html/daikin/altherma-eblq011cav3/altherma-eblq011cav3_user-reference-manual_501250008.webp)
4 Operation
User reference guide
8
EBLQ+EDLQ011~W1 + EK(2)CB
EKMB9W1
Daikin Altherma low temperature monobloc
4P522035-1 – 2018.01
You can…
Location
Define preset values.
Condition: Leaving water set point is linked
with the room temperature set point.
Only change this if the desired room
temperature cannot be reached.
Menu structure
See also:
▪
"4.4.6 Room thermostat control - Using the leaving water
temperature home pages" on page 9
▪
"4.7 Preset values and schedules" on page 16
4.4.5
Room thermostat control - Using the
room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To set the user profile, refer to
"4.6.6 Configuring user profile and home pages" on page 16
User profile = Basic
User profile = Detailed
15:20
20.0°C
Mon
Room
Actual temperature
15:20
20.0°C
17:30
Actual temperature
Room
Scheduled
Mon
Tue
To read out the actual and desired room
temperature
1
Go to the room temperature home page (Room).
Result:
You can read out the actual temperature.
20.0°C
Actual temperature
2
Press
.
Result:
You can read out the desired temperature.
22.0°C
Desired temperature
To temporarily overrule the room temperature
schedule
1
Go to the room temperature home page (Room).
2
Use
or
to adjust the temperature.
To change the mode from scheduled to preset
value
Prerequisite:
User profile = Detailed.
1
Go to the room temperature home page (Room).
2
Press
or
to select a preset value ( or ).
Result:
The mode will return to Scheduled according to the overrule
period.
Example: Temporarily overruling the schedule
AND changing the mode to preset value
You have configured the following settings:
Settings
Description
Preset values
Comfort (heating) =
20°C
Desired temperature when
you are at home.
Eco (heating) = 18°C Desired temperature:
▪ When you are away
▪ During the night
Schedule
07:00 Comfort
You are at home.
Desired temperature =
preset value (Comfort
(heating)).
09:00 Eco
You are away.
Desired temperature =
preset value (Eco
(heating)).
17:00 Comfort
You are at home.
Desired temperature =
preset value (Comfort
(heating)).
19:00 21°C
You are at home and want
it to be a little warmer.
Desired temperature =
custom temperature.
23:00 Eco
Desired temperature =
preset value (Eco
(heating)).
Overrule period
(Temperature
lock)
2 hours
If you temporarily overrule
the schedule by a preset
value, after 2 hours the
schedule will be used
again.
If user profile = Basic, then you can
temporarily overrule
the room
temperature schedule by pressing
or
.
Situation
Description
15:20
18.0°C
15:20
19.0°C
15:20 => Scheduled temperature
= preset value (Eco (heating)) =
18°C.
You
temporarily overrule
the
schedule.
Desired temperature = custom
temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be
used again.
If user profile = Detailed, then you can:
▪
Temporarily overrule
the room temperature schedule by
pressing
or
(same as if user profile = Basic)
▪
Change the mode
from scheduled to a preset value by pressing
or
Situation
Description
17:00
18.0°C
15:20
Mon
Scheduled
Room temperature
schedule
is
used.
15:20 => Desired temperature =
preset value (Eco (heating)) =
18°C.
The next scheduled action is at
17:00 and the desired
temperature will then increase.