4 Energy saving tips

Operation manual

8

EBLQ+EDLQ011~W1

Daikin Altherma low temperature monobloc

4P522032-1 – 2018.01

3.8

Installer settings: Tables to be
filled in by installer

3.8.1

Quick wizard

Setting

Default

Fill in…

Space heating/cooling settings [A.2.1]

Unit control method

2 (RT)

User interface location

1 (Room)

Number of LWT zones

0 (1 LWT zone)

Pump operation mode

2 (Request)

Glycol present

0 (No)

Outdoor unit [A.2.2]

DHW pump

0 (No)

External sensor (outdoor)

0 (No)

Control box [A.2.2.E]

Backup heater steps

0 (No BUH)

BUH type

1 (1P,(1/1+2))

Preferential kWh rate

0 (No)

DHW operation

0 (No)

Contact type main

1 (Thermo)

Contact type add.

1 (Thermo)

Option box [A.2.2.F]

Ext. backup heat src

0 (No)

Alarm output

0 (NO)

External kWh meter 1

0 (No)

External kWh meter 2

0 (No)

External sensor (indoor)

0 (No)

Capacities [A.2.3]

Booster heater

3 kW

BUH: step 1

3 kW

BUH: step 2

0 kW

3.8.2

Space heating/cooling control

Setting

Default

Fill in…

Leaving water temperature: Main zone [A.3.1.1]

LWT setpoint mode

1 (WD)

Leaving water temperature: Additional zone [A.3.1.2]

LWT setpoint mode

1 (WD)

Leaving water temperature: Delta T source [A.3.1.3]

Heating

5°C

Cooling

5°C

Leaving water temperature: Modulation [A.3.1.1.5]

Modulated LWT

1 (Yes)

Leaving water temperature: Emitter type [A.3.1.1.7]

Emitter type

0 (Quick)

3.8.3

Domestic hot water control [A.4]

Setting

Default

Fill in…

Type

1 (R+S)

Maximum setpoint

60°C if E-07=0

80°C if E-07=5

INFORMATION

There  is  a  risk  of  space  heating  (cooling)  capacity
shortage/comfort problem (in case of frequent domestic hot
water  operation,  frequent  and  long  space  heating/cooling
interruption  will  happen)  when  selecting  [6‑0D]=0  ([A.4.1]
Domestic  hot  water  Type=Reheat  only)  in  case  of  a
domestic hot water tank without an internal booster heater.

INFORMATION

When  the  DHW  tank  booster  mode  is  active,  the  risk  of
space  heating/cooling  and  capacity  shortage  comfort
problems  is  significant.  In  case  of  frequent  domestic  hot
water  operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

3.8.4

Contact/helpdesk number [6.3.2]

Setting

Default

Fill in…

Contact/helpdesk number

4

Energy saving tips

Tips about room temperature

▪ Make  sure  the  desired  room  temperature  is  NEVER  too  high  (in

heating  mode)  or  too  low  (in  cooling  mode),  but  ALWAYS
according  to  your  actual  needs.  Each  saved  degree  can  save  up
to 6% of heating/cooling costs.

▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up

space heating. The space will NOT heat up faster.

▪ When  your  system  layout  contains  slow  heat  emitters  (example:

under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.

▪ Use  a  weekly  schedule  for  your  normal  space  heating  or  cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature. 

Example: 

When  you  have  a  party,  or  when  you

are leaving for a couple of hours.

▪ For  longer  periods:  You  can  use  the  holiday  mode. 

Example:

When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage

comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

Summary of Contents for Altherma EBLQ011CAV3

Page 1: ...ow temperature monobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 ED...

Page 2: ...entation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he...

Page 3: ...e on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Na...

Page 4: ...he indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You...

Page 5: ...ht because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the...

Page 6: ...Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below...

Page 7: ...metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Pres...

Page 8: ...tage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Defa...

Page 9: ...your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Incre...

Page 10: ...backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system tre...

Page 11: ......

Page 12: ...4P522032 1 2018 01 Copyright 2018 Daikin 4P522032 1 0000000C...

Reviews: