3 Operation

Operation manual

3

EBLQ+EDLQ011~W1
Daikin Altherma low temperature monobloc
4P522032-1 – 2018.01

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Control box EKCB07CAV3

c

Domestic hot water (DHW) tank

d

User interface connected to the control box

e

User interface in the living room, used as room thermostat

f

Underfloor heating

g

Heat pump convectors or fan coil units

h

Option box EK2CB07CAV3

3

Operation

3.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating/cooling
control

How to control space heating/cooling:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches between home pages (when you are on a home

page).

▪ Goes to the default home page (when you are in the menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages.
Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens  the  menu  structure  (when  you  are  on  a  home

page).

▪ Goes  up  a  level  (when  you  are  navigating  through  the

menu structure).

▪ Goes back 1 step (example: when you are programming a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or

between  displaying  actual  and  offset  values  (if  applicable)
on the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

Domestic hot water operation.

Actual temperature.

Desired temperature.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Button lock mode and/or function lock mode is active.

An external heat source is active. 

Example: 

Gas

burner.

The disinfection mode is active.

Summary of Contents for Altherma EBLQ011CAV3

Page 1: ...ow temperature monobloc English Operation manual Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3 ED...

Page 2: ...entation carefully before operating the user interface to ensure the best possible performance Request the installer to inform you about the settings that he used to configure your system Check if he...

Page 3: ...e on a home page Goes up a level when you are navigating through the menu structure Goes back 1 step example when you are programming a schedule in the menu structure e NAVIGATING CHANGING SETTINGS Na...

Page 4: ...he indoor temperature and taking monthly restrictions into account Note Automatic changeover is only possible under certain conditions To restrict automatic changeover operation mode Prerequisite You...

Page 5: ...ht because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time 3 4 3 Scheduled reheat mode In scheduled reheat mode the...

Page 6: ...Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below...

Page 7: ...metering Consumed elec Produced energy Error information Error history Contact helpdesk number Version User interface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Pres...

Page 8: ...tage comfort problems is significant In case of frequent domestic hot water operation frequent and long space heating cooling interruptions will happen 3 8 4 Contact helpdesk number 6 3 2 Setting Defa...

Page 9: ...your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Incre...

Page 10: ...backup heater or booster heater takes over the heat load electricity consumption will be considerably higher 7 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system tre...

Page 11: ......

Page 12: ...4P522032 1 2018 01 Copyright 2018 Daikin 4P522032 1 0000000C...

Reviews: