background image

5 Operation

Operation manual

10

EB23D

Daikin Altherma 3 R F

4P643606-1B – 2022.08

Item

Description

k Additional zone

k1

Installed room thermostat type:

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

k2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

k3

45

Leaving water temperature setpoint

(a)

l

Malfunction

A malfunction occurred.

See 

"8.1 To display the help text in case of a

malfunction"

 [

4

 18] for more information.

(a)

If the corresponding operation (for example: space heating) is not
active, the circle is greyed out.

5.3.2

Main menu screen

Starting from the home screen, press (

) or turn (

) the

left  dial  to  open  the  main  menu  screen.  From  the  main  menu,  you
can access the different setpoint screens and submenus.

a

2

Main zone

Additional zone

Room

Malfunctioning

Space heating/cooling

a

Selected submenu

Possible actions on this screen

Go through the list.

Enter the submenu.

Enable/disable breadcrumbs.

Submenu

Description

[0]

 or 

Malfunctioning

Restriction: 

Only displayed if a

malfunction occurs.

See 

"8.1 To display the help text in

case of a malfunction"

 [

4

 18] for more

information.

[1]

 

Room

Restriction: 

Only displayed if a

dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the indoor
unit.

Set the room temperature.

[2]

 

Main zone

Shows the applicable symbol for your
main zone emitter type.

Set the leaving water temperature for
the main zone.

[3]

 

Additional zone

Restriction: 

Only displayed if there

are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.

Set the leaving water temperature for
the additional zone (if present).

Submenu

Description

[4]

 

Space heating/

cooling

Shows the applicable symbol of your
unit.

Put the unit in heating mode or cooling
mode. You cannot change the mode
on heating only models.

[5]

 

Tank

Set the domestic hot water tank
temperature.

[7]

 

User settings

Gives access to user settings such as
holiday mode and quiet mode.

[8]

 

Information

Displays data and information about
the indoor unit.

[9]

 

Installer

settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

[A]

 

Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

[B]

 

User profile

Change the active user profile.

[C]

 

Operation

Turn heating/cooling functionality and
domestic hot water preparation on or
off.

[D]

 

Wireless

gateway

Restriction: 

Only displayed if a

wireless LAN (WLAN) is installed.

Contains settings needed when
configuring the ONECTA app.

5.3.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Examples

[1] Room temperature screen

+

21

°C

1

Room

[2] Main zone screen

+

35

°C

2

Main zone

[3] Additional zone screen

+

45

°C

3

Additional zone

[5] Tank temperature screen

+

50

°C

5

Tank

Explanation

a1

d

+

d

e

d

e

c

a2

b1

b2

Possible actions on this screen

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Summary of Contents for Altherma 3 R F EBVZ16S18D 6V Series

Page 1: ...Operation manual Daikin Altherma 3 R F English Operation manual Daikin Altherma 3 R F EBVZ16S18D 6V EBVZ16S23D 6V EBVZ16S18D 9W EBVZ16S23D 9W A B C Z 1 2 3 9...

Page 2: ...Tables to be filled in by installer 20 11 1 Configuration wizard 20 11 2 Settings menu 20 1 About this document INFORMATION This unit is a heating only model Therefore all references to cooling in thi...

Page 3: ...a safe way and understand the hazards involved Children SHALL NOT play with the appliance Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical...

Page 4: ...e you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to...

Page 5: ...al room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2 2 Set operation to On or Off To change the desir...

Page 6: ...Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather depend...

Page 7: ...darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the screens menus and settings of the LCD screen To set values...

Page 8: ...tpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activati...

Page 9: ...lure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currently be...

Page 10: ...your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temperature zones Shows the applicable symbo...

Page 11: ...ion Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control...

Page 12: ...n mode to Automatic 1 Go to 4 2 Space heating cooling Operation mode schedule 2 Select a month 3 For each month select an option Reversible Not restricted Heating only Restricted Cooling only Restrict...

Page 13: ...the domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the D...

Page 14: ...to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room Heat...

Page 15: ...nfirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 5 9 Weather dependent curve 5 9 1 What is a weather d...

Page 16: ...proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water f...

Page 17: ...Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers 5 C...

Page 18: ...his unit is mildly flammable WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a...

Page 19: ...ater heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not Al...

Page 20: ...Configuration wizard Setting Fill in System Indoor unit type read only Backup heater type 9 3 1 read only Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Backup heater Voltage 9 3 2 Config...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P643606 1B 2022 08 Copyright 2021 Daikin 4P643606 1 B 0000000 Verantwortung f r Energie und Umwelt...

Reviews: