15
|
Disposal
Installer reference guide
270
EPRA14~18D + ETSH/X(B)16P30+50E
Daikin Altherma 3 H HT ECH₂O
4P679467-1B – 2022.09
b
1
2
a
b
a
b
a
Fill and drain kit
b
Screw plug
4
Connect the loose end of the drain hose to an appropriate drain.
To drain the storage tank
NOTICE
Water immediately surges from the storage tank when the sealing plug of the drain
connection is removed. Make sure to adequately collect the spillage.
1
Place an appropriate tray under the drain connection to collect water spillage.
2
Open the screw plug and remove the sealing plug and IMMEDIATELY close
with the previously prepared screw plug with drain connection.