EPRA14~W1 + ETBH/9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
Configuration
The indoor unit can control DHW pump operation. For more information, see
5.4.6 DHW pump for tank preheating
Setup
M
b
c
a
d
e
f
a
DHW tank
b
Cold water IN
c
Hot water OUT (shower (field supply))
d
Motorised 3‑way valve (field supply)
e
DHW pump (field supply)
f
Non‑return valve (field supply)
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
"8.3.5 To connect the domestic hot water
112].
▪
For the standalone DHW tank: If there is no electrical backup heater in the space
heating circuit, you must install a DHW pump for tank preheating.
Configuration
The indoor unit can control DHW pump operation. For more information, see
5.5 Setting up the energy metering
▪
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
▪
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production