3 About the system

Operation manual

3

ADEQ35~125C2VEB
Split system air conditioners
4P461580-1 – 2016.09

NOTICE

Improper  installation  or  attachment  of  equipment  or
accessories  could  result  in  electric  shock,  short-circuit,
leaks,  fire  or  other  damage  to  the  equipment.  Only  use
accessories,  optional  equipment  and  spare  parts  made  or
approved by Daikin.

WARNING

Ask  your  dealer  to  move  and  reinstall  the  air  conditioner.
Incomplete  installation  may  result  in  a  water  leakage,
electric shock, and fire.

WARNING

Never replace a fuse with a fuse of a wrong ampere ratings
or  other  wires  when  a  fuse  blows  out.  Use  of  wire  or
copper wire may cause the unit to break down or cause a
fire.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

WARNING

Do  not  place  a  flammable  spray  bottle  near  the  air
conditioner and do not use sprays. Doing so may result in
a fire.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

DANGER: RISK OF ELECTROCUTION

Do  not  operate  the  air  conditioner  with  wet  hands.  An
electric shock may result.

NOTICE

▪ Do  NOT  place  any  objects  or  equipment  on  top  of  the

unit.

▪ Do NOT sit, climb or stand on the unit.

CAUTION

Never  expose  little  children,  plants  or  animals  directly  to
the air flow.

CAUTION

To  avoid  injury,  do  NOT  touch  the  air  inlet  or  aluminium
fins of the unit.

WARNING

Do not place objects in direct proximity of the outdoor unit
and do not let leaves and other debris accumulate around
the unit. Leaves are a hotbed for small animals which can
enter  the  unit.  Once  in  the  unit,  such  animals  can  cause
malfunctions,  smoke  or  fire  when  making  contact  with
electrical parts.

INFORMATION

The sound pressure level is less than 70 dBA.

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

▪ Do not modify, disassemble, remove, reinstall or repair

the unit yourself as incorrect dismantling or installation
may  cause  an  electric  shock  or  fire.  Contact  your
dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  non-combustible,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  In  this  condition,  condensation  on  the
main unit or refrigerant pipes, air filter dirt or drain blockage
may cause dripping. This results in fouling or failure of the
object which is located beneath the unit.

CAUTION

To  avoid  oxygen  deficiency,  ventilate  the  room  sufficiently
if equipment with burner is used together with the system.

3

About the system

WARNING

Ask  your  dealer  to  install  and  reinstall  the  air  conditioner.
Incomplete  installation  may  result  in  a  water  leakage,
electric shock, and fire.

NOTICE

Improper  installation  or  attachment  of  equipment  or
accessories  could  result  in  electric  shock,  short-circuit,
leaks,  fire  or  other  damage  to  the  equipment.  Only  use
accessories,  optional  equipment  and  spare  parts  made  or
approved by Daikin.

3.1

Components

INFORMATION

The  following  illustration  is  an  example  and  might  NOT
match your system layout.

b

f

a

h

c

d

e

g

a

Indoor unit

b

Outdoor unit

c

Remote controller

d

Air inlet

e

Air outlet

f

Refrigerant piping and electric wiring

Summary of Contents for ADEQ100C2VEB

Page 1: ...Operation manual Split system air conditioners English Operation manual Split system air conditioners ADEQ35C2VEB ADEQ50C2VEB ADEQ60C2VEB ADEQ71C2VEB ADEQ100C2VEB ADEQ125C2VEB ...

Page 2: ...ings and symbols DANGER Indicates a situation that results in death or serious injury DANGER RISK OF ELECTROCUTION Indicates a situation that could result in electrocution DANGER RISK OF BURNING Indicates a situation that could result in burning because of extreme hot or cold temperatures DANGER RISK OF EXPLOSION Indicates a situation that could result in explosion WARNING Indicates a situation th...

Page 3: ...ire when making contact with electrical parts INFORMATION The sound pressure level is less than 70 dBA INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons WARNING Do not modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may cause...

Page 4: ...o ensure smoother operation As soon as the power is turned on the remote controller display appears If there was a power failure during operation the system automatically restarts immediately after the power supply is recovered Set the temperature range of the remote controller is described in chapter Operation range If you select a function which is not available the message NOT AVAILABLE appears...

Page 5: ...ir filter is very dirty use a soft brush and neutral detergent 3 Dry the air filter in the shadow 4 Reattach the air filter Align the 2 hanger brackets and push the 2 clips in their place and pull the cloth if necessary rear suction bottom suction 5 Confirm that 4 hangers are fixed 6 In case of bottom suction shut the air inlet grille 7 Turn ON the power 8 Press the FILTER SIGN RESET button Result...

Page 6: ...the temperature setting Refer to the manual of the remote controller Check the fan speed setting is set to low speed Refer to the manual of the remote controller Check if the air flow angle is proper Refer to the manual of the remote controller Check for open doors or windows Shut doors and windows to prevent wind from coming in Check if direct sunlight enters the room Use curtains or blinds Check...

Page 7: ...s in cooling or defrost operation This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the noise of refrigerant caused by flow stop or flow change A squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contra...